Midwestern Engineers, Inc. Plan Preview

3" VENT THRU ROOF PLUMBING FIXTURE SCHEDULE WC- 1 UR- 1 LAV-1 ACORN - SIPHON JET TOILET MODEL# R2 1 41-W-3-EG 16 GAUGE, lYPE 3D4 STAINLESS STEEL, WHITE ENAMEL FINISH 1 !," INLET SPUD, WALL SUPPLY 1 7" ADA RIM HEIGHT SLOAN MODEL 1 40 ESS-1.28-DF B -OR-2- 1 0-3/4-LDIM-HW-24V ACORN - HIGH EFFICIENCY URINAL MODEL# DURA-WARE 2 1 58-W-0.5 GPF-FV B O-EG 1 6 GAUGE, lYPE 304 STAINLESS STEEL, WHITE ENAMEL FINISH ¾" TOP INLET SPUD, WASHOUT FLUSHING ACTION, 0.5 GPF 1 7" AOA RIM HEIGHT SLOAN MODEL 195 ESS-0.5-DF B -L/OR-2-10-3/4-LDIM-HW-24V ACORN - LAVATORY MODEL# DURA-WARE 1 951LC- 1 -9-H34-EG 20"x 1 8", 1 6 GAUGE, lYPE 304 STAINLESS STEEL, WHITE ENAMEL FINISH SLOAN MODEL SF-2300-PLG- B DM-CP-0.5GPM-MLM-IR-FCT TRUE B RO LAVSHIELD ¾" RIM HEIGHT WH-1 LOCHINVAR - JUNIOR ELECTRIC WATER HEATER MODEL# JER- 1 0 SCO 1 0 GAL., 1 20V- 1 0, 1650W SIX WAY SHELF MOUNT JKT 3004 FD- 1 JAY R. SMITH - FLOOR DRAIN MODEL# 204 1 S TRAP w/ FLOOR CLEANOUT ADJUSTA B LE STRAINER HEAO & SECURED GRATE H B - 1 WOODFORD - BACKFLOW PROTECTED WALL FAUCET MODEL# 826 METAL WHEEL HANDLE DF-1 HALSEY TAYLOR - DRINKING FOUNTAIN MODEL# HRF-SE B P Bl-LEVEL, NON-FILTERED, NON-REFRIGERATED STAINLESS STEEL 42"/36" TO B UB B LER SEWER ISOMETRIC TMV- 1 LAWLER - THERMOSTATIC MIXING VALVE MODEL# 6 1 - 1 0 3.5 GPM @ 1 0 PSI PRESSURE DROP, D.5 GPM MINIMUM ASSE 10 1 7 COMPLIANT 6B WATER HEATER (WH- 1 ) LAV- 1 -o G ½" ½" NOT TO SCALE ½" ¾" 1 ½" HEADER ½" LAV-1 1½" PIPE THRU FLOOR MAIN SHUTOFF VALVE UR- 1 1 ½" H B -1 1!," HEADER WC- 1 NOTE: WATER PIPING SHALL B E SLOPED SO THE ENTIRE SYSTEM CAN B E DRAINED DOWN ANO WINTERIZED. PROVIDE LOW POINT DRAINS WHERE TRAPPED SECTIONS OF PIPE EXIST. ASME TEMPERATURE --__ , AND PRESSURE " RELIEF VALVE 0 I �¾" I I I 1--1--THERMOMETER BALL VALVE (TYP) /SPRING CHECK THERMOSTATIC MIXING VALVE (TMV-1) WATER HEATER (WH-1) ELEMENT ACCESS PANEL ',,,,_ --- f - ---- t"' .-----STAINLESS STEEL DRAIN PAN .-+---L; �SHELF BY WATER HEATER �-------� MANUFACTURER WATER ISOMETRIC DETAIL 'C' WATER HEATER B RONZE PLUG 2" COMPACTED SAND B ED r;---rir >' Ill I '----UL I WYE AND J. BEND/ WITH CLEANOUT EXTENSION TO GRADE (SWING JOINT) r;--ilr NOT TO SCALE CLEANOUT BOX WITH SOLID COVER JAY R. SMITH 4253S-NB 18"x18 H x6 n D CONCRETE PAD GRADE DEPTH TO SEWER VARIES WYE ANO J. B END IF PLACED IN SEWER LINE. /, BEND IF PLACED AT END OF SEWER LINE. �FLOW >' Ill '-, '- ---UL-- -::,. -1.IJ ---' DETAIL 'A 1 EXTERIOR CLEANOUT NOT TO SCALE NOT TO SCALE - FRAME WITH SOLID COVER NEENAH UICK-COUPLER AIR CONNECTION- Q ( COORDINATE SlYLE W/OWNER) #R-6450-KL (STAMPED 'WATER") .-GROUT VOID AREA ½" B ALL TYPE E \ BETWEEN MANHOLE FRAME ETE PIPE SHUTOFF VALV ANO CONCR GRADE ' 30" TO B UILDING, I - 48" (MIN) ER TO PLAN FOR- CT PIPE SIZE REF EXA AND INVERTS 30 CD ON AN "0x6'-0" LONG NCRETE PIPE WITH E PLAIN CUT END D ONE B ELL END E VALVE WITH NCRETE BLOCK GAT co SU VAL PPORT AND VE EXTENSION � JQ n � - II I "' "' :flt • 6" (MIN) • I � \ • • • o • O · • • •· "o· o,!- •: • 0 ?,J- 0 ° -•g 'o o.o·•·• • <1g. ··.°• ... - · •• · · - • [GRAVEL B ED DETAIL 1 8' DRAIN DOWN PIT NOT TO SCALE , FROM WATER SERVICE 1------q \_ 4 " r::7 EXTERIOR CLEANOUT LJ INV.� 522.75 ___ _,_________. GENERAL PLUMBING NOTES WORK INCLUDES FURNISHING ALL LA B OR, MATERIALS, APPLIANCES, EQUIPMENT, TOOLS, TRANSPORTATION, SUPERINTENDENCE, CLEAN-UP, AND SERVICES REQUIRED TO CONSTRUCT ANO INSTALL A COMPLETE AND FULLY OPERATIVE PLUM B ING SYSTEM FOR THE PROJECT. INSTALL ALL PLUM B ING WORK IN ACCORDANCE WITH ALL STATE AND LOCAL CODES, ALL ADA ANO ACCESSI B ILITY LAWS AND REGULATIONS, AND ALL AUTHORITIES HAVING JURISDICTION. UNLESS OTHERWISE SPECIFIED, ALL FAUCETS, SUPPLIES AND STOPS, TRAPS, WASTES, STRAINERS, AND ESCUTCHEONS, SHALL B E CHROME PLATED B RASS. (BRIGHT CHROME FINISH). TEST ALL PIPING AS REQUIRED B Y STATE AND LOCAL PLUM B ING CODES. TEST ALL NEW PIPING TO 1 50 PSI FOR A MINIMUM OF 24 HOURS. DISINFECTION AND STERILIZATION OF THE SYSTEM SHALL B E PERFORMED IN ACCORDANCE WITH ALL RULES AND REGULATIONS OF THE STATE B OARD OF HEALTH. FURNISH ALL CERTIFICATES OF APPROVALS B Y THE PLUM B ING INSPECTOR AND B OARD OF HEALTH. SANITARY DRAIN, WASTE, ANO VENT PIPING: INSIDE B UILDING TO B E SCHEDULE 40 PVC, DWV FITTINGS DESIGNED FOR SOLVENT WELDED JOINT CONSTRUCTION. DOMESTIC WATER PIPING: INSIDE BUILDING TO B E HARD COPPER TU B E, TYPE "L", ASTM 888, NSF 61 FITTINGS SHALL BE WROUGHT COPPER, ASME 8 1 6.22. JOINTS SHALL B E LEAD-FREE SOLDER, ASTM 832. COORDINATE WITH UTILITY TO PROVIDE NEW SANITARY SEWER SERVICES AND CONNECTIONS AS REQUIRED. VERIFY PIPING ROUTING AND RUNS, TAP LOCATIONS, AND INVERT ELEVATIONS REQUIRED PRIOR TO COMMENCING WORK. ESTA B LISH INVERT ELEVATIONS REQUIRED FOR DRAINAGE OF )a" PER FOOT SLOPE. ENSURE FOR PROPER CONNECTIONS, INSTALL, AND SLOPE FOR DRAINAGE. FURNISH 1 20/24 VAC TRANSFORMERS AS REQUIRED FOR SENSOR FAUCET AND FLUSH VALVE POWER CONNECTIONS; EQUAL TO SLOAN EL-154. WATER PIPING SHALL B E SLOPED SO THE ENTIRE SYSTEM CAN BE DRAINED DOWN AND WINTERIZED. PROVIDE LOW POINT DRAINS WHERE TRAPPED SECTIONS OF PIPE EXIST. (C\ WATER HEATER GD (WH-1) LAV-1 2 UR- 1 ½" J FD- 1 I FD-1 2" UNISEX R.R.#1 WC- 1 3 4 " �=L==l ½ = " ���t-������H= B -= 1 � 1 �·�--�-L-���-� l&=l ; , , , , ; UR- 1 2" UNISEX R.R.#2 WC- 1 PROPOSED PLUMBING PLAN SCALE: ½" � 1'-0" FINISH FLOOR ELEVATION: 524.50' PLAN NOTES G) REFER TO SITE UTILITY PLAN FOR CONTINUAION. (;) INSTALL PIPE SLEEVE THRU FOUNDATION WALL, COORDINATE w/ STRUCTURAL DRAWINGS. CTJ 1 !," DOMESTIC WATER THRU FLOOR SLA B . INSTALL MAIN SHUTOFF VALVE. @) 1 " COLO WATER, 2" VENT. @ 1 !," COLO WATER HEADER. SLOPE DOWNWARDS TOWARDS HOSE B IB B . @ ¾" COLD WATER, 2" WASTE, 1!," VENT. (2) ½" HOT AND COLD WATER, 1 ½" WASTE, 1 ½" VENT. @ ½" COLD WATER, 1!," WASTE, 1!," VENT. @ 3" VENT THRU ROOF. @ ½" COLD WATER DOWN, J," 1 20' HOT WATER UP FROM WATER HEATER, MOUNT ON MANUFACTURER FURNISHED SHELF ANO ATTACH ON CHASE WALL AS HIGH AS POSSI B LE (SHOWN OFFSET FOR CLARITY). IU) 4" CLOSET FLANGE, 4" WASTE. @ COORDINATE PLUM B ING INSTALLATION TO AVOID ELECTRICAL PANELS IN THIS AREA. G) 1 ½" � DRAIN DOWN PIT GD 1½" 2 G) RE.VISIONS 10/25/23 BID SET 0 2023 Midwestern Engineers. Inc. 802 Wes! Bro,,rlw:,y Street P.O. Box 295 Loogootee. Indiana 47553 DATE OCTOBER 2023 DESIGN WAE DRAWN CNM Q.C. CHECK CWR PROJECT NUMBER 2022024-05 39 39 OF 48 I Fll£ NUMBER 53550 I Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2