Midwestern Engineers, Inc. Plan Preview

u o' �· u 1;' 0 0 �o >: �o � 0 8 :, '.1 .J N sf " :;;: 9 Q ' N 00 oO " "'I � o �N ., - � ' ii -- "'I -� � � ·O Cl Nu .., �z z_ oo• , By " N £ .j; " . ·� INSTALL VALVE W/PLUG & CONC. THRUST BLOCK FOR HYDRANT AT END OF LINE CONC. THRUST BLOCK MAIN .. ' I I NOTE: VALVE BOXES SHALL BE SCREW TYPE 2-P!ECE OR 3-PIECE CAST IRON WITH CAST-IRON LID IN ALL STONE. ASPHALT OR CONCRETE SURFACE AREAS. ANCHORING COUPLING FLUSH HYDRANT WITH MECHANICAL JOINT CONN. APPROX. T-0" OR AS DIRECTED BY ENGINEER VALVE BOX '\_ COVER B ALUMINUM VALVE-' I _____ 1�IN 2o·I D.I. MECHANICAL JOINT TEE NOTE: USE REDUCING TEE IF REQUIRED BOX TOP MAIN 6" SDR 35 PVC PIPE I GATE VALVE D.I. TEE ANCHORING COUPLING MJN. 2'-0.. DETAIL OF FLUSH HYDRANT CONNECTION #4EPOXY COATED REBAR BENT AS SHOWN 0 0 FLUSH HYDRANT (SEE SPECS) PRECAST CONC. SLABS OR STONE WEDGED ftffl-- BETWEEN HYDRANT AND FIRM FACE OF TRENCH l6 CUBIC FEET OF WASHED GRAVEL OR WASHED STONE #5 NOTE: WATER METER & PRESSURE REDUCING VALVE COMBINATION AS SHOWN SHALL BE INSTALLED ON ALL SERVICES 3/4" OR I" PRESSURE REDUCING VALVE MODEL BR4 WITH A REDUCED OUTLET PRESSURE RANGE OF 15 TO 150 P.S.l. AS MANUFACTURED BY WILKINS (A ZURN COMPANY) ANGLE DUAL CHECK----�VALVE YOKE WITH BRACING EYE �--SEE SPECIFICATION METER YOKE TO EXTEND THRU WALL WITH ¾' ' ' -- -COPPER DUAL PURPOSE OUTLET CONNECTION / // I \ I HIGH STRENGTH POLYPROPYLENE METER BOX FRAME & COVER BRASS NIPPLES 20" l.D l{DPE METER PIT 30" DEEP SEE SPECIFICATIONS ANGLE BALL VALVE METER COPPERSE1TER SEE SPECIFICATIONS METER SEE SEPEC!FlCATIONS ,/4" OR l" H.D.P.E. SDR-9 C.T.S. SERVICE FROM MAIN 16" LONG SCH. 80 RIGID P.V.C. PIPE BRACE, 1/2" DIA. STANDARD 20" ID METER PIT 30" DEEP PRESSURE GAUGE STANDARD COPPER METER IDLER WITH 0-200 P.S.J. TAPPED PRESSURE GAUGE. GAUGE SHALL BE OF MATERIAL SUITABLE FOR GROUND WATER CONDITIONS. TO DETERMINE EXACT FLOW LOSSES, 5/8" x 3/4" WATER METER SHALL BE INSERTED IN PLACE OF IDLER. FORD CAT. No. VV-92-12 WITH FULL PORT WING BALL STOPS ON BOTH ENDS AND BRACING EYE. (OR EQUAL)----- GATE VALVE---, I REDUCER lF REQ'D� STANDARD METER BOX COVER SET FLUSH WITH GROUND SURFACE � :;- ALUMINUM VALVE BOX TOP & COVER 6" SDR-35 PVC PIPE .. / GATE VALVE DI. TEE ....___ _ REDUCER IF REQ'D ......._ - --GATE VALVE WATER MAIN BELL RESTRAINT HARNESS MEGALUG BY EBAA IRON, INC. REQ'D FOR 2 JOINTS BEYOND FITTING EACH WAY D.l. FITTING WITH MECHANICAL � ----------- - -,-- JOINT RESTRAINED TO PIPE BY USE OF A MEGALUG BY EBAA IRON, INC. DETAIL OF PRESSURE REDUCING VALVE & WATER METER 16" LONG RIGID P.V.C. PIPE BRACE 1/2" DlA. D.l. TEE 1 �---11:i:ib�"'�'' STONE BED A* - ;:,,r .. . I MJN. or 40LF. j �� I ::!7ra=r=n "- - " - - I � -=IP� •• , BELL RESTRAINT HARNESS '--,+-----MEGALUG BY EBAA IRON, INC. REQ'D FOR 2 JOINTS BEYOND FITTING EACH WAY FLEXIBLE UTILITY MARKER WlTH TWO TERMINAL TEST ACCESS POINTS FOR TRACER WIRE, COLOR BLUE MODEL "TUFFCAT" CTFC07208U WITH DECALS CW-112 AND TOF-2580 AS MANUFACTURED BY CARSONlTE INTERNATIONAL, PH. 1-800-648-7917 (OR EQUAL) TO BE INSTALLED AT 1000 Ff. MAXlMUM SPACING. #4EPOXY COATED REBAR IN FENCELINES. ADJACENT TO FIRE/FLUSH HYDRANTS ETC. STONE BED VolUlC . AI.. BENT AS SHOWN • SEE SPECIFICAT!ONsSTONE BED HORIZONTAL TYPICAL THRUST BLOCK DETAIL EXISTING MAIN • MUELLER #H-304SS STAINLESS STEEL. TAPPING 'rEE w1nl ss OlITLET - FLANGE(OR EQUAL.) - MUELLER FLxMi GATE TAPPING VALVE tOI, EQUAL) ANCHOR BARB ATTACHMENT TRACER WIRE SHALL BE No. 12 AWG USE-2, RHW-2 OR RHH SOLID COPPER WIRE WITH 45 MIL POLYETHYLENE INSULATION AND SUITABLE FOR DIRECT BURIAL INSTALLED LONGITUDlNALLY ALONG THE PIPE TRENCH. ALL UNDER GROUND SPLICES IN TRACER WIRE SHALL BE CONNECTED WITH A 3M ELECTRICAL PRODUCT DIVISION No. 054007-09053 DIRECT BURIAL SPLICE KlT.• w ! 11 "' 01 II � 11 I GRADE -NEW MAIN EXISTING MAIN LOCATION MARKER WITH TRACER WIRE TERMINAL TEST POINTS DETAIL OF WET TAP TO EXISTING MAIN POL)'ETHYLENE ENCASEMENT REQUIRED FOR ALL D l. PIPE TWO SPACERS PLACED 6' • 10' TYPICAL • 1 BRICK/MORTAR (TYPICAL) PIPE 2' FROM BELL E SEAL CASING WITH AT EACH END OF CASING BETWEEN SPACERS ( CASING PER SPEClFICATlON � TRACER ""RL:i= = =\;ti""' = = = ==== ========= =, == =il=zcz!:c ===== cp === !=zj WIRE t � L NYLON CABLE TJES FOR TRACER WIRE. MIN. 2 PER PIPE CARRIER PIPE NOTE: VALVE BOXES SHALL BE SCREW TYPE, 2-PIECE OR 3 - PlECE CAST IRON WITH CAST IRON LID IN ALL STONE, ASPHALT OR CONCRETE AREAS. VALVE BOX COVER � BUT!'ERFLY VALVE MUELLER>----LINESEAL XP (250 PSJ) OR THE HENRY PRATJ' EQUIVALENT LEAK DETECTION DEVICE HOLLOW COPPER TUBE TERMINAL TEST ACCESS POINT INSERT TRACER WIRE INTO TUBE AND CRlMP NO. 12 COPPER TRACER WIRE NOTE: CONTRACJ'OR SHALL BE REQUIRED TO PROVIDE PHOTOGRAPHS OF THE FIELD TILE REPAIR (BOTH PRIOR TO AND AFfER REPAIR) PRIOR TO EARTH LOAM BACKFILL. THE CONTRACTOR SHALL PROVIDE CLOW F-20 0R MUELLER #H-840 CUT-IN SLEEVE (OR EQUAL) EXISTING MAIN MUELLER FLxMJ GATE VALVE (OR EQUAL) EXISTING MAIN A LABELED 3-RING BJNDER CONTAINING THE REQUIRED PHOTOGRAPHS. EACH PHOTOGRAPH SHALL BE PROPERLY LABELED WITH THE PROPER STATIONING, SIZE OF TILE REPAIR, DATE OF REPAIR AND PROPERTY OWNER. P.V.C. PIPE SAME SIZE AS CUT FIELD TILE EARTH LOAM BACKFILL CUT-IN SLEEVE FOR VALVE OR TEE TO EXISTING MAIN FERNCO ADA P TER (OR EQUAL) EXISTING _7 �~·<JLµ e-==== FIELD TILE 2' MIN. FERNCO ADAPTER (OR EQUAL) �>,------+--- -----cr+"Tir-] -- - - - m_+-' ,- '\:::EXISTING 2'MIN, FIELD TILE #53 STONE BACKFILL LINDER P V C. PIPE WATER LINE FIELD TILE REPAIR DETAIL #6 REINF. RODS (2 REQ'D.) CONC. PAD GATE VALVE IF REQ'D-� ANCHOR COUPLING OR ' -� FOSTER ADAPTER STONE MIN.Of40LF, 0 --- -D.L OR P.V.C. MAIN LINE PIPE (TYP.) BELL RESTRAlNT HARNESS ''------MEGALUG BY EBAA IRON. INC. REQ'D FOR 2 JO[NTS (M]N. 40') BEYOND FITTING /VALVE EACH WAY �--VALVE WITH MECHANICAL JOINT RESTRAINED TO PIPE BY USE OF MEGALUG BY EBAA IRON, INC. 1- t.1IN. OF 40LF. GATE VALVE IF REQ'D ANCHOR COUPLING OR FOSTER ADAPTER STAINLESS STEEL CASING SPACERS WITH POLYMER RUNNERS AS MANUFACTURED BY CASCADE WATERWORKS MFG. PH l-800-426-4301 BUTTERFLY VALVE DETAIL GATE VALVE IFREQ'D ANCHOR COUPLING OR FOSTER ADAPTER D.I. TEE CONCRETE THRUST BLOCK TYPICAL CASING SPACERS AND END SEALS DETAIL DETAIL OF BRANCH CONNECTION FOR DUCTILE, CAST IRON OR PLASTIC PIPE WATER DETAILS REVISIONS PRELIMINARY NOT FOR CONSTRUCTION C 2024 Midwcslem Engineers. Inc. 802 Wesl Broadw"v Street P 0. Box 29.5 Loogooc,xo. lndiuna47553 DAJE FEBRUARY 2024 DESIGN CWR DRAWN DRKLBDH Q.C. CHECK RAB PROJECT NUMBER 2022038-04 3 1 31 OF 48 I FILE NUMBER I 43897 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2