Midwestern Engineers, Inc. Plan Preview
0 w r � w 0 w < z w '" � - � - > a 0 � w 0 • < M tj � � � ,, • <o Q ,, . ,. Q .- 1 �� " N- > '0 - ii: q- 1 �� 0 .. -� • a 2r < "" �UJ <!! - a: - Q 2� !al "o :i: >U oz o-, OD �5 U, .� 5, ,. <c GENERAL ELECTRICAL NOTES NO MORE THAN SIX CURRENT CARRYING CONOUCTORS (INCLUDING NEUTRAL CONDUCTORS) IN ANY ONE CONDUIT CARRYING 20-AMP LIGHTING OR RECEPTACLE LOADS WITHOUT DERATING IN ACCORDANCE WITH NEC ARTICLE 310. ALL OTHER CIRCUITS SHALL BE IN A DEDICATED CONDUIT PROVIDE GROUNO CONDUCTOR IN ALL CONDUITS. SIZE PER NATIONAL ELECTRIC CODE. ALL WIRING SHALL COMPLY WITH THE LATEST EDITION OF THE INDIANA ELECTRIC CODE AND COMPLY WITH COUNTY AND/OR LOCAL JURISDICTION HAVING AUTHORITY IN THAT AREA ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR THE EXACT LOCATION AND ROUGH-IN REQUIREMENTS FOR ALL MECHANICAL EQUIPMENT AND PIPING BEFORE ROUGH-IN. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES AND OWNER BEFORE WIRING IS TO BEGIN TO VERIFY ALL OTHER CONDITIONS SO THAT WIRING WILL NOT INTERFERE WITH THE OTHER TRADES. ALL ELECTRICAL SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE ENTIRE ELECTRICAL SYSTEM SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. ALL MATERIALS USED IN THE WORK SHALL BE APPROVED BY THE UNDERWRITER'S LABORATORIES, INC., AND SHALL BEAR THEIR LABEL. THE CONTRACTOR SHALL, AT HIS/HER OWN EXPENSE, OBTAIN ALL PERMITS, INSPECTIONS, CERTIFICATES, AND LICENSE REQUIRED BY LAW FOR THE EXECUTION OF WORK TO BE PERFORMED. THE ELECTRICAL CONTRACTOR, UNLESS OTHERWISE NOTED, SHALL FURNISH AND INSTALL ALL MATERIAL AND EQUIPMENT AS INDICATED ON THE DRAWINGS. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND OF FIRST CLASS CONSTRUCTION, AND SHALL BE THE PRODUCT OF AN ESTABLISHED AND REPUTABLE MANUFACTURER, AND SHALL BE DESIGNED TO PERFORM THE SERVICE REQUIRED. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL HARDWARE, LAMPS, ACCESSORIES, ETC. AS REQUIRED FOR A COMPLETE ANO WORKING SYSTEM. MULTI-WIRE (SHARED NEUTRAL CIRCUITS) SHALL NOT BE USED. PROVIDE A NEUTRAL CONDUCTOR FOR EACH LINE-TO-NEUTRAL CIRCUIT ALL POWER AND CONTROL CIRCUIT WIRING USED SHALL BE 'THHN" OR "THWN" COPPER UNLESS OTHERWISE SPECIFIED OR REQUIRED BY COOE. PER NEC 310.10, ALL WIRING SHALL BE SIZED TO COORDINATE WITH TEMPERATURE RATINGS OF TERMINATIONS. LISTED WIRE SIZES ON PANELBOARD SCHEDULES ARE MINIMUM SIZES. SIZE WIRE TO MEET TEMPERATURE AND VOLTAGE DROP REQUIREMENTS. PROVIDE A PULL ROPE IN ALL SPARE CONDUITS. PROVIDE ID TAG AT EACH END OF PULL ROPE IDENTIFYING LOCATION OF OPPOSITE END. ELECTRICAL SYMBOLS ARE NOT SHOWN TO SCALE. WHEN DEVICES ARE SHOWN ADJACENT, INSTALL IN ADJACENT BOXES. COMPLY WITH BOX FILL REQUIREMENTS OF NEC ARTICLE 314. PROVIDE CONDUIT EXPANSION FITTINGS WHERE CROSSING BUILOING EXPANSION JOINTS. ALL SAFETY SWITCHES SHALL BE "HEAVY DUTY" OWNER RESERVES FIRST RIGHTS TO ANY REMOVED EQUIPMENT AND MATERIALS. ALL UNWANTED EQUIPMENT AND MATERIALS SHALL BE DISCARDED BY CONTRACTOR PER LOCAL, STATE AND FEDERAL REGULATIONS AT NO ADDITIONAL COST TO THE OWNER. IT SHALL BE THE GENERAL CONTRACTORS RESPONSIBILITY TO FULLY COORDINATE THE SCOPE OF SERVICES BETWEEN THE EXISTING SCADA SYSTEM INTEGRATOR AND THE PROJECT ELECTRICIAN. THIS SHALL INCLUDE BUT NOT NECESSARILY BE LIMITED TO CONTROLS PANELS; CONTROL DEVICES; POWER/CONTROL WIRING AND CONDUIT; ANALOG, DIGITAL, ETHERNET, FIBER PERTAINING TO DESIRED PLANT OPERATIONS INCLUDING THE EXISTING AND PROPOSED EQUIPMENT. ALL PROPOSED CONDUITS SHALL BE SCH. 80 PVC IF BURIED w/ MINIMUM 24" COVER AND WARNING TAPE AT 12" DEEP. ALL EXPOSED CONDUITS ABOVE GRADE SHALL BE ALUMINUM, TYPICALLY USE STAINLESS JUNCTION/PULL BOXES FASTENED w/ STAINLESS HARDWARE. CONTRACTOR SHALL MAINTAIN HORIZONTAL SEPARATION BETWEEN WATER, SEWER AND GAS OF 36" MIN. AND A VERTICAL SEPARATION OF 12" MIN. TWISTED SHIELDED PAIR BY BELOEN FOR ALL ANALOG 1/0, COORDINATE FLOW TRANSMITTER/CONVERTER READOUTS w/ OWNER AND ENGINEER DURING CONSTRUCTION PRIOR TO INSTALLATION. SEPARATE ALL POWER AND CONTROL; DIGITAL, ANALOG, ETHERNET AND FIBER INTO DEDICATED CONDUITS. CONTRACTOR TO LOCATE ALL UNDERGROUND UTILITIES PRIOR TO EXCAVATION. SEED, STRAW AND/OR STONE ALL SURFACES TO PRE-DISTURBED CONDITION. CONTRACTOR TO SEAL AROUND ALL BUILDING PENETRATIONS w/ NON-SHRINK GROUT, TYPICALLY USE LB FITTINGS. FRONT VIEW -14¾"- JUNCTION BOX STAINLESS STE CABLE ACCESS ALUMINUM EL 1!1 16½"1!1 1 " CONTINUOUS PIANO HINGE . I l j L..,__14"-- • • RIGHT SIDE VIEW lie " 7"- LEFT SIDE VIEW -7%"- FACE-MOUNT PADLOCKABLE HASP LOUVER PLATES STAINLESS STEEL ALUMINUM MESH NOTE, JUNCTION BDX DIMENSIONS SHOWN ARE FOR REFERENCE ONLY, CONTRACTOR TO SIZE FOR APPLICABLE PUMP APPLICATION. JUNCTION BOX DETAIL - 24" NOT TO SCALE LENGTH OF STAND x 4' DEEP . . • , , • . • . . . . • t - - I • • , .. • ' " " 12" ALUMINUM ANGLE WELDED TO ALUMINUM BASE PLATE (4) ½" STAINLESS STEEL ALL-THREADS IN CONCRETE • • 4"x4"x¼." • ALUM. ANGLE .L. • ½" ALUM. BASE PLATE • . BASE DETAIL NOT TO SCALE • \ OVERHEAD PRIMARY DUKE ENERGY TO R \ .,, t " t i " ,f ' I /"•-� "'-- /1 OVERHEAD PRIMA" R c" Y "' B = y ...., e-- DUKE ENERGY TO REMAIN EXISTING TRANSFORMER POLE BY DUKE ENERGY TO REMAIN I • •• r l • l I ' \I II I II II II PL ii I II II II II II II -w II II II " _, II II I l ! ,..__,,�EXISTING OVERHEAD • 12D/24DV-30, 4W POWER TO MAIN LIFT STATION TO REMAIN II " // // " // I, // II II il II // I/ II '' , ' I � // II II II " // II II " II II " 1, 11 // " // 11 II !----'CONTRACTOR TO PROVIDE AND INSTALL FIBER COMMUNICATIONS ON STAINLESS CARRIER WIRE FROM WWTP SCADA PANEL IN CONTROL BUILDING TO MAIN LIFT STATION SCADA PANEL AS SHOWN • ' , ' ' ' ' ' , ' ' I ' I I j :z I I , I I ' ' I I , ' , I ,-' ?' a I's ri � Q C 1+----EXISTING OVERHEAD 120/24DV-30, 4W POWER TO MAIN LIFT STATION TO REMAIN ,f � ,. PROPOSED UV SYSTEM (ALTERNATE BID ITEM) • • ' ; ,, ' I ' I ' I ' I ' I ' PROPOSED OVERALL ELECTRICAL SITE PLAN SCALE, 1" = 40' I REVISIONS 9/1/2023 BID SET (t) 2023 1-Jjdwc,ternEngi�<·r,. Inc. sm IVc,1 Bro:odway su,,,·t 1'.0 ilo� "95 Loogook'<'. !ndi,ma ..\7553 DATE SEPT. 2023 DESIGN A.F.B. DRAWN C.N.M. Q.C. CHECK R.D.W. PROJECT NUMBER 2022111-00 17 17 OF 23 FlLE NUMBER 43306 I Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2