Midwestern Engineers, Inc. Plan Preview
� I w� �" <o m• •om9 � N o- �l1 �§ �g _:§ � �o i:i� g-, ��u90 N "C" PHASE HIGH LEG EXISTING 1 n_ QAMPERES PANEL 120/2.!QVOLTS LP1 - , WIRE CIRCUIT! NO. I ITEM FEED 1 LAB LIGHTS NORTH WALL 3 WALL PACKS 5 HIGH LEG --�M�C=BMAIN CONNECTION -----�WWI.E_C..Ol:JTROI BlJII.D.lliG.LOCATION SIJREACE MOUNTING ---��PHASE KAIC .S.E.L. WIRE CU. WIRE SIZE AMPS POLE BUS POLE AMPS SIZE CIRCUIT ITEM FEED NO. 12 20 A 1 20 12 LAB RECEPTACLES 2 12 20 B 1 20 12 BLOWER ROOM HEATER 4 C HIGH LEG 6 7 BLOWER ROOM LIGHTS 12 20 1 A 1 20 12 POLE LIGHTS 8 �9jLA�B�R� ECCEE:P P� TA�cg, c�sjsgo�U!fTH�W� AL1L=j�12tj�2ot:b 1 =t�sjj:1j::2�otj::::i1t 2j�sP� AR�EC:::'=======P104- -WWTP SCADA PANEL 11 HIGH LEG C HIGH LEG 12 IF ALT 810 IS NOT 13 CHLORINE ROOM LIGHTS 12 20 A 1 20 12 FLOW METER 14 ACCEPTED 15 GENERATOR HEATER 17 HIGH LEG 19 SPARE 21 SPARE 23 HIGH LEG 25 SPARE 27 SPARE 29 HIGH LEG 31 SPARE 33 SPARE 1 � LPJ TRANSFORMER ,.E_ 39 41 HIGH LEG * NOTE: EATON CAT.# QBHW3090H 12 20 12 20 12 20 12 20 12 20 12 20 12 20 3 90 3 B 1 20 12 BLOWER 2 COOLING FAN 16 C HIGH LEG 18 A 1 20 12 BLOWER 1 COOLING FAN 20 B 1 20 12 SPARE 22 C HIGH LEG 24 A 1 20 12 SPARE 26 B C A B C A B C 1 20 12 SPARE 28 20 20 HIGH LEG 12 SPARE 12 SPARE HIGH LEG SPACE SPACE HIGH LEG 30 32 34 36 38 40 42 PANEL 100 AMPERES MCB MAIN CONNECTION wwre COf::lIBQI BlJII DING LOCATION LP3 120,/208 VOLTS ,, WIRE CIRCUIT I NO. ITEM FEED ,_J_ UV POWER DISTRIBUTION CENTER ..l.. 5 7 UV WP CONV. OUTLET 9 UV SYSTEM CONTROL CENTER 11 SPARE 13 SPARE 15 SPARE 17 SPARE 19 SPARE 21 SPARE 23 SPARE 25 SPARE 27 SPARE 29 SPARE 'PHASE KAIC WIRE SIZE AMPS POLE 12 15 3 12 20 1 10 20 1 12 20 1 12 20 1 12 20 1 12 20 1 12 20 1 12 20 1 12 20 1 12 20 1 12 20 1 12 20 1 SlJRFACFMOUNTING S.E.L CU. WIRE BUS POLE AMPS SIZE ITEM FEED A 3 20 10 UV HYDRAULIC SYSTEMS CENTER B C A 1 20 12 WWTP SCADA PANEL B 1 20 12 SPARE C 1 20 12 SPARE A 1 20 12 SPARE B 1 20 12 SPARE C 1 20 12 SPARE A 1 20 12 SPARE B 1 20 12 SPARE C 1 20 12 SPARE A 1 20 12 SPARE B 1 20 12 SPARE C 1 20 12 SPARE CONTROL BUILDING SCADA NOTES CIRCUIT NO. 2 � 4 � 6 8 10 12 14 16 18 20 22 24 26 28 30 1. CONTRACTOR SHALL UTILIZE OWNER'S EXISTING SCADA SYSTEM INTEGRATOR BY CONTACTING NATHEN BURKHART AT TORIC ENGINEERING AT 317-718-18DO TO PROVIDE SCADA PRICING PRIOR TO BID. PROVIDE NEW SCADA PANEL IN NEMA 1 ENCLOSURE AT EXISTING CONTROL BUILDING WITH THE FOLLOWING FEATURES: A. ALLEN BRADLEY COMPACTLOGIX PLC w/ EXPANSION 1/0 8. CONTROL RELAYS, AS NEEDED C. CONVENIENCE RECEPTACLE D. ENCLOSURE, WALL MOUNT, TYPE 12, PAINTED STEEL E. FIBER OPTIC PATCH PANEL F. MAIN CIRCUIT BREAKER G. MAPLE SYSTEMS TOUCHSCREEN, 12" H. NETWORK SWITCH, 6-ETHERNET PORTS, 2-FIBER PORTS I. POWER SUPPLY, 24VDC J. TERMINAL BLOCKS, AS NEEDED K. lVSS, 120VAC L. UPS BATTERY BACKUP M. UL 508A LISTING 2. RTU INPUTS/OUTPUTS DIGITAL INPUTS: CLARIFIER #1 HIGH TORQUE CLARIFIER #1 HIGH HIGH TORQUE CLARIFIER #1 OVERLOAD CLARIFIER #2 HIGH TORQUE CLARIFIER #2 HIGH HIGH TORQUE CLARIFIER #2 OVERLOAD RAS/WAS PUMP #1 RUN STATUS {ON/OFF) RAS/WAS PUMP #1 RUN STATUS (ALARM) RAS/WAS PUMP #2 RUN STATUS (ON/OFF) RAS/WAS PUMP #2 RUN STATUS (ALARM) RAS/WAS PUMP STATION HIGH LEVEL INFLUENT FLOW METER TOTALIZED FLOW EFFLUENT FLOW METER TOTALl2ED FLOW BLOWER VFD #1 RUN STATUS (ON/OFF) BLOWER VFD #1 RUN STATUS (ALARM) BLOWER VFD #2 RUN STATUS (ON/OFF) BLOWER VFD #2 RUN STATUS (ALARM) DIGITAL OUTPUTS: BLOWER VFD #1 START COMMAND BLOWER VFD #2 START COMMAND ALARM DIALER OUTPUT #1 ALARM DIALER OUTPUT #2 ALARM DIALER OUTPUT #3 ALARM DIALER OUTPUT #4 ALARM DIALER OUTPUT #5 ALARM DIALER OUTPUT #6 ALARM DIALER OUTPUT #7 ALARM DIALER OUTPUT #8 ANALOG INPUT: INFLUENT INSTANTANEOUS FLOW FROM EXISTING HONEYWELL CHART RECORDER EFFLUENT INSTANTANEOUS FLOW FROM OCM Ill UNLESS UV ALT BID IS ACCEPTED OTHERWISE FROM NEW VEGA MET842 TRANSMITTER BLOWER VFD #1 BLOWER VFD #2 DO PROBE ANALOG OUTPUTS: SPEED REFERENCE SPEED REFERENCE NEW SENSOR FEED FROM LP1-10 IF ALT BID IS NOT ACCEPTED 1" TO CLARIFIER #1-- - - - ---::f' CP DIGITAL I 1" TO CLARIFIER #2 f • C.P. DIGITAL I 1" TO RAS C.P. DIGITAL- -- --7 " • 1" FOR ETHERNET TO -- - -'f I uv sec I • 1" TO UV sec FOR ANALOG ;-( " • EFFLUENT FLOW SIGNAL I • 1" CONDUIT UV PDC l POWER • • 1" CONDUIT UV HSC----f • • • • POWER 1" CONDUIT UV sec___)' • • • POWER " " I • I I ; 1" CONDUIT UV WP-- 1 • • •�\.._ CONV OUTLET -1 hl ' POWER • ' ' - - ' --- CHLORINE ROOM EXISTING INFLUENT FLOW METER TOTALIZER TO REMAIN I W" ... � �� ' p ' IM h L, ' '" ' 'V'" ll " " - • l EXISTING KROHN INFLUENT • ' ' • ' . 0 " • ' FLOW METER TO REMAIN '"' 0 '" � PROPOSED 120/208V-30, 4W WYE IOOA PANEL LP3 '' '\, V I " ' LP1-35,37,39 ' --- ' --- ' I I I 1� l FIBER IN CONDUIT TO MAIN LIFT STATION I I 1 l EXISTING ALARM DIALER OFFICE/LAB r CONTROL WIRING IN CONDUIT TO SCAOA PER 1/0 LIST EXISTING HONEYWELL INFLUENT FLOW� ) CHART RECORDER TO REMAIN � ' --- � I @, r ==PROPOSED WWTP__ \ SCADA PANEL --+---->Ir LP3-8 CONTROL WIRING IN CONDUIT PER 1/0 LIST BLOWER ROOM NOTE: SEPARATE POWER AND CONTROL: DIGITAL, ANALOG, ETHERNET AND FIBER ' --- PROPOSED 30KVA LP3 TRANSFORMER ON 4" CONCRETE HOUSEKEEPING PAD EXISTING 120/240V-30, u 4W HIGH LEG DELTA IOOA PANEL LP1 EXISTING MCC1 l DIST. CONTROL WIRING IN CONDUIT TO SCADA PER 1/0 LIST I I BLOWER #2 BLOWER # 1 VFO VFO TO REMAIN DIST. MAIN & SPD EXISTING MILLTRONICS OCM Ill EFFLUENT FLOW READOUT TO REMAIN IF UV ALTERNATE BID IS NOT ACCEPTED. 1" CONDUIT FOR ANALOG TO EFFLUENT FLOW METER PIT AT UV FOR NEW RADAR LEVEL SENSOR CABLING IF UV ALTERNATE BID IS ACCEPTED. USE EXISTING CONDUIT PROVIDE NEW AS REQUIRED. E � 1" CONDUIT ANO WIRE TO DO PROBE, MIN 24" COVER BLOWER VFD #1 PACING SIGNAL BLOWER VFD #2 PACING SIGNAL EFFLUENT FLOW PACING SIGNAL TO UV VIA SPLITTER (ALT. BID ONLY) c.,_____ rn ----- rn _____.,,_ �--_J ETHERNET: 1-- UV SYSTEM CONTROL CENTER (ALT. BID ONLY) •MODIFY EXISTING HOUSEKEEPING PAD AS REQUIRED FIBER: MAIN LIFT STATION 3. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIAL, WIRING AND PROGRAMMING TO ACCOMMODATE THE NEW 1/0 AS EXISTING WWTP CONTROL BUILDING ELECTRICAL PLAN SCALE: ½" 0 I'-0" �t½:===============================================================================================================================================================� se� � • u I:: - REVISIONS 9/1/2023 BID SET ti 2023 MidW\Cstan Engi11<. --e1,. Inc. 80.l We,1 Br<�1d"'" Str�cl P.O. Box 295 Looi:0<,1c,:. ]ndian:i -17553 DATE SEPT. 2023 DESIGN A.F.B. DRAWN C.N.M. Q.C. CHECK R.D.W. PROJECT NUMBER 2022111-00 19 19 OF 23 FlLE NUMBER 43304 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2