Midwestern Engineers, Inc. Plan Preview
PUTNAM COUNTY HIGHWAY DEPARTMENT HIGHWAY ENGINEER/ SUPERINTENDENT JIM PECK jim.peck@co.putnam.in.us PH: 765-655-5004 PUTNAM COUNTY COMMISSIONERS COMMISSIONER'S OFFICE 1 COURTHOUSE SQUARE, SUITE 20 GREENCASTLE, IN 46135 PH: 765-653-5992 DAVID BERRY RICK WOODALL THOMAS HELMER INDIANA DEPARTMENT OF TRANSPORTATION CRAWFORDSVILLE DISTRICT DEBBIE CALDER, DEPUTY COMMISSIONER 41 WEST 300 NORTH CLOVERDALE SUB-DISTRICT 10 NORTH HIGH ST. CLOVERDALE, IN 46120 DISTRICT PERMIT MANAGER JUSTIN PATTERSON PH: 1-765-376-6769 DISTRICT PERMIT INSPECTOR AFTON TRIBBY PH: 1-765-230-7496 CRAWFORDSVILLE, IN 47933 PH: 1-855-463-6848 EMAIL: dcalder@indot.in.gov SHEET SCHEDULE 1. COVER SHEET 2. PROJECT INFORMATION AND OVERALL MAP 3. EXISTING HYDRAULIC PROFILE 4. PROPOSED IMPROVEMENTS AND EXISTING HYDRAULIC PROFILE 5. EQUALIZATION BASIN - SITE PLAN 6. EQUALIZATION BASIN - CROSS SECTIONS 7. EQUALIZATION BASIN - CROSS SECTIONS AND DETAILS 8. EQUALIZATION BASIN - AERATOR ASSEMBLY DETAILS 9. TYPICAL DETAILS 10. WASTEWATER TREATMENT PLANT - EXISTING SITE PLAN 11. WASTEWATER TREATMENT PLANT - BEAM DEMOLITION DETAILS 12. WASTEWATER TREATMENT PLANT - BEAM REPLACEMENT PLAN 13. WASTEWATER TREATMENT PLANT - BEAM REPLACEMENT DETAILS 14. WASTEWATER TREATMENT PLANT - NEW U.V. STRUCTURE PLAN 15. WASTEWATER TREATMENT PLANT - NEW U.V. STRUCTURE DETAILS 16. WASTEWATER TREATMENT PLANT- NEW U.V. STRUCTURE DETAILS GENERAL NOTES: EMAIL: jpatterson1@indot.in.gov 17. PROPOSED OVERALL ELECTRICAL SITE PLAN EMAIL: atribby@indot.in.gov 18. PROPOSED WASTEWATER TREATMENT PLANT ENLARGED ELECTRICAL SITE PLAN 19. EXISTING WASTEWATER TREATMENT PLANT CONTROL BUILDING ELECTRICAL PLAN 20. NEW U.V. STRUCTURE ELECTRICAL PLAN 21. PROPOSED WASTEWATER TREATMENT PLANT AND MAIN LIFT STATION POWER DISTRIBUTION ONE-LINE DIAGRAM 22. PROPOSED ENLARGED ELECTRICAL SITE PLAN 23. MAIN LIFT STATION ELECTRICAL PLAN 1. TOPOGRAPHY SHOWN ON PLAN SHEETS IS INTENDED TO SHOW THE GENERAL LOCATION OF FENCES, CULVERTS, DRIVES, EXISTING UTILITIES, POINTS OF CONNECTION, ETC. HOWEVER; THE EXACT LOCATION AND QUANTITIES SHALL BE VERIFIED AT THE TIME OF CONSTRUCTION. 2 THE HORIZONTAL LOCATION DATA IS BASED UPON THE INDIANA STATE PLANE COORDINATE SYSTEM (WEST ZONE) REFERENCED TO THE 1983 NORTH AMERICA DATUM (NAD83) ELEVATIONS ARE BASED UPON THE 1988 NORTH AMERICAN VERTICAL DATUM (NAVO 88). 3. THE CONTRACTOR SHALL CALL INDIANA UNDERGROUND SERVICES AT 1-800-382-5544 PRIOR TO ANY CONSTRUCTION TWO FULL WORKING DAYS BEFORE CONSTRUCTION IS TO BEGIN. 4. THE LOCATION OF EXISTING UTILITIES ETC. SHOWN ON THESE PLANS ARE NOT THE EXACT LOCATIONS BUT ONLY A GENERAL LOCATION ALTHOUGH THESE PLANS HAVE ATTEMPTED TO SHOW ALL EXISTING UTILITIES, THE CONTRACTOR SHALL NOT ASSUME ALL EXISTING UTILITIES HAVE BEEN SHOWN. THEREFORE IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO SEE THAT ALL EXISTING UTILITIES WITHIN CONSTRUCTION AREAS ARE CLEARLY MARKED IN THE FIELD PRIOR TO ANY CONSTRUCTION IN THE AREA. 5. EXACT LOCATION OF MANHOLES, LATERALS, CLEANOUTS, ETC. TO BE DETERMINED AT THE TIME OF CONSTRUCTION. 6. DOWN TIME COORDINATION MUST BE MADE WITH THE SEWER UTILITY PRIOR TO TEMPORARILY SHUTTING DOWN A SEWER MAIN AND/OR LIFT STATION. A MINIMUM OF TEN (10) WORKING DAYS NOTIFICATION IS REQUIRED. COORDINATE WITH NICK MILLER AT 765-522-1532. 7. PROPERTY LINES, WHERE SHOWN, ARE BASED ON COUNTY PLAT RECORDS. THE SAID PROPERTY LINES ON THESE SHEETS DO NOT REPRESENT PROPERTY SURVEYS, BUT ARE ONLY APPROXIMATE LOCATIONS FOR REFERENCE PURPOSES ONLY. 8. IF ANY ARCHEOLOGICAL ARTIFACTS OR HUMAN REMAINS ARE UNCOVERED DURING CONSTRUCTION, THE CONTRACTOR SHALL STOP ALL EXCAVATION WORK AND CONTACT THE INDIANA DEPARTMENT OF NATURAL RESOURCES, DIVISION OF HISTORIC PRESERVATION AND ARCHEOLOGY, PHONE No. 317-232-1646. NO ADDITIONAL EXCAVATION WORK SHALL BE DONE WITHOUT RECEIVING THEIR APPROVAL. 9. THE CONTRACTOR SHALL BE REQUIRED TO IMPLEMENT DUST CONTROL MEASURE (SURFACE WETTING) AS NECESSARY TO MINIMIZE FUGITIVE DUST EMISSIONS. 10. IF CAVERNS OR SPRINGS ARE ENCOUNTERED DURING EXCAVATION, WORK SHALL STOP IMMEDIATELY AND THE INDIANA DEPARTMENT OF NATURAL RESOURCES OR THE U S. FISH & WILDLIFE OFFICE SHALL BE CONTACTED CONCERNING PROPER MITIGATION MEASURES. UTILITIES WATER, WASTEWATER STORMWATER: TELEPHONE: TOWN OF ROACHDALE 205 N. INDIANA ST. ROACHDALE, IN 46175 CONTACT: NICK SMITH PH: 1-765-522-1532 COMMUNICATIONS CORPORATION/ TDS TELECOM 525 JUNCTION RD MADISON, WI 53717 CONTACT: BRIAN RESCH PH: 1-608-664-0148 EMAIL: brian.resch@tdstelecom.com CONTACT: JEFF STANLEY PH: 1-765-522-0113 EMAIL: jeff.stanley@tdstelecom.com Q d 111111- I 711..•·••·••LZ....... GAS: ELECTRIC: CENTERPOINT ENERGY (SOUTH) 1800 W. 26TH ST MUNCIE, IN 47302 CONTACT: JON EASTHAM PH: 1-765-287-2119 EMAIL: publicproject@centerpointenergy.com PANHANDLE EASTERN PIPELINE 8910 PURDUE RD. INDIANAPOLIS, IN 46268 CONTACT: JOEL NORTON PH: 1-317-879-3039 EMAIL: joel.norton@energytransfer.com DUKE ENERGY 100 S MILL CREEK RD. NOBLESVILLE, IN 46062 CONTACT: DON MCDUFFY PH: 1-317-776-5320 EMAIL: dei-dline-coord@duke-energy.com r;; I I PROPOSED EQ BASINL---r-'j�f'; PROPOSED BEAM REPLACEMENT AND NEW U.V. STRUCTURE PROJECT LOCATION ROACHDALE WASTEWATER TREATMENT PLANT I I I I ,as I I I "' � I . I I : I __ _,. .93 .. " D ci r � - " 59 • • 58 . ' I -7 ""� '�1 "" ---1 57 I " - .)4 _. I " I "· 1/:: I 56� I I , 'I r 250 500 , .- , --, ::�· ., ,·�-=,._=,_,_ , ... ,,.,... � ..------.�_-"'. ~-:--· _, 92 f' "• i;JI,' -.:,e ,,._ �. • n 'l 67 68 ' • 103 107S! 105S 106S"" E. CO. RD. 1225 N 4Q "<f. - .. �� 38- � ... - • " , .. �·- - 53 55 ,, • > - • ,,_- f . � - ... - . " ... 15 " E. CO. RD. 1220 N .. • PROJECT INFORMATION AND OVERALL MAP REVISIONS BID SET C 20D Midwe.1tem Engineers. Inc. 802 Wost Broadway Strcci P.O. Box 295 Loogootee, Indiana 47553 DATE SEPT. 2023 DESIGN R.D.W. DRAWN M.M.C. Q.C. CHECK PROJECT NUMBER 2022111-00 2 2 OF 23 I FlLE NUMBER 43321 I Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2