I w w 0 � 0 oo' 0 z i'i ! �1 .� <o Q --.._ - oc Q r-J �9 "" N• � 0 - s::q::;: � �o u w -� � w � �Iii a" Q -� "• :I! �o >- 0 az o-, �" 0',,! CN � j; , . <� UV SYSTEM INTERCONNECTION NOTES DESCRIPTION FROM TO POWER DISTRIBUTION CENTER (PDC) 208V-3¢ LP3 IN PDC POWER SUPPLY CONTROL BLDG. 208V-3¢, 3 WIRE + GROUND 3.1 KVA/PDC POWER DRAW 9 AMPS MAX. CURRENT/PHASE SYSTEM CONTROL CENTER (SCC) 12OV-10 LP3 IN sec ·,oucH SMART PLUS" POWER SUPPLY CONTROL BLDG 12DV-1¢, 2 WIRE + GND. 1.44 KVA, 12 AMPS HYDRAULIC SYSTEMS CENTER (HSC) 208V-3• LIGHTING PANEL HSC POWER SUPPLY LP3 IN CONTROL BLDG. 208V-3¢, 3 WIRE + GND. 2.5 KVA, 7 AMPS FLOW METER EFFLUENT FLOW METER sec 4-20mA, DC ANALOG INPUT SIGNAL FROM PLANT SCADA PANEL GROUND LINK sec PDC THRU 12 AWG TYPE TWH STRANDED MODBUS sec PDC THRU 1 SHIELDED TWISTED PAIR LEVEL CONTROL BOX (LCP) PDC LCP POWER SUPPLY 24 voe, 2 CONDUCTORS DISCRETE LOW LEVEL SENSOR LOW LEVEL SENSOR PDC 24 voe, 2 CONDUCTORS DISCRETE WATER LEVEL SENSOR LCP PDC 24 voe, 2 CONDUCTORS HSC HSC MODBUS ETHERNET (PLC) COMMUNICATION sec PLANT SCADA 1" CONDUIT AND WIRE TO NEW TRANSMITTER IN LAB, MIN. 24" COVER ' 1 w + ! ' I - i H t ' I ,.L � .+ l ··� I ' ! ,, I I I I I I t- ' ' -� � 1 1< � -; ' � "'t +· t i j . ' . " ' ' '' ' I , I \t!ttHr "' < /\ ? I ' I ' I ,! " I ' I : I I' I I . I . , , LOW LEVEL SENSOR LEVEL SENSOR CONTROL BOX (LCP) CONTRACTOR TO PROVIDE AND INSTALL NEW VEGA C21 RADAR LEVEL TRANSDUCER, CLASS I DIV I RIGID CONDUIT AND CABLING WITHOUT SPLICES BACK TO READOUT IN LAB UTILIZE VEGA MET842 TRANSMITTER, NO EQUAL. I I , I I ALUMINUM UNI-STRUT 4"x4" ALUMINUM ANGLE EFFLUENT FLOW FRO PLANT SCADA ETHERNET TO PLANT SCADA M • - SYSTEM CONTROL CENTER (sec) .!.! r- LP3-9 TO HSC � j7 .. HSC � PDC 0 0 .. P3-1,3.' LP3-2,4,6 - CONTRACTOR TO PROVIDE ANO INSTALL 208V, 30A-3P NON-FUSED DISCONNECT IN NEMA 4X S.S. ENCLOSURE. CONTRACTOR TO PROVIDE AND INSTALL 208V, 30A-3P NON-FUSED DISCONNECT IN NEMA 4X S.S. ENCLOSURE. WEATHERPROOF CONV. OUTLET (LP3-7) TO PDC SEE BASE DETAIL UV UNISTRUT STAND DETAIL NOT TO SCALE I I I I FOR CABLE ROUTING OPENING IN GRATING \ \ ' " " ' 1· 11 I -� "'-Li. .;l- I 'I I ' I DISCRETE LOW LEVEL SIGNAL AND 24V DC POWER SUPPLY IN CONDUIT (3) #12 THWN (1) #12 CU. GND. 1" CONDUIT LP3-7 ( - � " , I - - - " " 0 (PDC) w/ HYDRAULIC MANIFOL / POWER DISTRIBUTION CENTER D I II I ' I, JL ' . , } h i f! I I \ - ,.It I ' , ,, 0 ' , I I 11 4"¢ ,HYDRAULIC DUCTING ' MODBUS COMMUNICATION SIGNAL I U GROUND LINK WIRING IN CONDUI � • � HYDRAULIC SYSTEMS • CENTER (HSC) I - BY CONTRACTOR WIRING IN CONDUIT T GROUND LINK =� WP CONV OUTLET iu I U "'I .. l O 0 WIRING IN CONDUIT (l:J i i LP3-1,3,5 LP3-2,4,6 UV STRUCTURE ELECTRICAL PLAN i LP3-9 □ MODBUS COMMUNICATION SIGNAL WIRING IN CONDUIT L> SYSTEM CONTROL CENTER (sec) NOTE, IF UV ALTERNATE BID IS NOT ACCEPTED, CONTRACTOR TO STILL INSTALL ALL ASSOCIATED POWER AND CONTROL CONDUITS TO PULL BOX FOR FUTURE UV SYSTEM. ID ALL CONDUITS w/ PULL ROPE TO LAB/ELECTRICAL ROOM AT CONTROL BUILDING SCALE, ½" ~ 1'-0" WASTEWATER TREATMENT PLANT- U.V. STRUCTURE ELECTRICAL RE\IISIONS 9/1/2023 BID SET 0 2023 Midw,-,i-·rn Enuinecr.,. Inc. 801 W�,1 llroa,lway S11ret P.O. Bo, 10� Lc�>goo1ee. lndiam .i755; DATE SEPT. 2023 DESIGN A.F.B. DRAWN C.N.M. Q.C. CHECK R.D.W. PROJECT NUMBER 2022111-00 20 20 DF 23 FILE NUMBER 43303 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2