Midwestern Engineers, Inc. Plan Preview
0 0 w 0 g is 0 0 w ,., � z I � �" << " oO "oc i:i ---- �8 rl M• N" ---- Oo 1: ..-j g� • �§ u r. .w " -� � •w 0� ~• � i:i Q� ol "o �" oz g~ � SI "\l "� == , . <c PROPOSED MODIFICATIONS BUBBLE NOTES 0 THE EXISTING ONE LINE DIAGRAM IS SHOWN FOR REFERENCE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID. 0 0 0 0 0 0 0 @ ® THE CONTRACTOR SHALL PROVIDE DEDICATED CONTROL CONDUITS ANO WIRING FROM SCADA TO THE EXISTING VFDS TO ACQUIRE MONITORING ANO CONTROL VIA THE SCADA SYSTEM AS INDICATED ON THE 1/0 LIST. THE CONTRACTOR SHALL PROVIDE AND INSTALL A NEW 90A-3P BRANCH CIRCUIT BREAKER CAT# QBHW3090H INTO THE EXISTING 100A EATON PANELBOARD LP1 IN THE EXISTING CONTROL BUILDING ELECTRICAL ROOM, THEN FEED THE PROPOSED 30KVA THREE PHASE TRANSFORMER PRIMARY AS INDICATED. PROVIDE UPDATED, TYPED AND LAMINATED PANEL SCHEDULE AT COMPLETION OF PROJECT. (3) #3 THWN (1) #8 CU. GNO. 1) f ' CONDUIT. (4) #3 THWN (1) #8 CU. GNO. 1½" CONDUIT 30KVA TRANSFORMER, 240V-3¢ f,, PRIMARY TO 12D/208V-3¢ WYE SECONDARY, COPPER WINDINGS, NEMA 1 ENCLOSURE INSTALLED ON 4" CONCRETE HOUSEKEEPING PAD SQ. 0 NQ PANELBOARD IN NEMA 1 ENCLOSURE, SURFACE MOUNT, INTEGRAL SPD, 1ODA MAIN CIRCUIT BREAKER, 120Y/208V-30, 4W. PROVIDE OVERCURRENT PROTECTION PER UV MANUFACTURER'S RECOMMENDATIONS AND APPROVED SHOP DRAWINGS. PROVIDE TYPED AND LAMINATED PANEL SCHEDULE AT COMPLETION OF PROJECT. THE CONTRACTOR SHALL PROVIDE AND INSTALL NEW CIRCUIT BREAKERS AS REQUIRED FOR FULLY FUNCTIONAL SYSTEM. PROVIDE UPDATED, TYPED AND LAMINATED PANEL SCHEDULE AT COMPLETION OF PROJECT. THE CONTRACTOR SHALL RELOCATE EXISTING MAIN LIFT STATION PUMP CONTROL PANEL INTO EXISTING ELECTRICAL BUILDING AS SHOWN, THEN RECONNECT ALL POWER ANO CONTROL WIRING IN CONDUIT AS REQUIRED FOR FULLY FUNCTIONAL SYSTEM. REPLACE EXISTING JUNCTION BOX WITH NEW AS SHOWN TO RECONNECT EXISTING AND PROPOSED POWER AND CONTROLS. CONTRACTOR TO PROVIDE ANO INSTALL NEW MAIN LIFT STATION SCAOA SYSTEM PLC, SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. SEE SCADA NETWORK DIAGRAM FOR ADDITIONAL INFORMATION. ALL LOCAL FIBER, ETHERNET, DIGITAL AND ANALOG SHALL BE SEPARATED INTO DEDICATED CONDUITS WIRED PER 1/0 LIST INDICATED ON DRAWINGS. CONTRACTOR TO PROVIDE AND INSTALL NEMA RATED, SIZE 1, ACROSS THE LINE MOTOR STARTER IN NEMA 1 ENCLOSURE w/ AMBIENT TEMPERATURE COMPENSATING THERMAL OVERLOADS, SQ. 0 CLASS 8536. COORDINATE ALL NECESSARY AUX CONTACTS FOR SCADA CONTROL /MONITORING AS INDICATED. (3) #1D THWN (1) #1D CU. GND. 1" CONDUIT 240V-30 TO SURFACE AERATOR PER NEC AND MANUFACTURERS RECOMMENDATIONS 30A-3P NON-FUSIBLE, HEAVY DUTY SAFETY SWITCH IN NEMA 4X S.S. ENCLOSURE (2) #12 THWN (1) #12 CU. GND. 1" CONDUIT ELECTRICAL CONNECTIONS IN VALVE VAULT TO BE CLASS I DIV. I PER NEC, USE ALUMINUM CONDUIT AND FITTINGS. EXISTING AUTOMATIC-� TRANSFER SWITCH 240V-3¢, 400A TO REMAIN I ,� 1 'r�j = 1 • EXISTING 120/240V-3¢, 4W HIGH LEG DELTA ELECTRIC SERVICE BY DUKE ENERGY TO REMAIN 1 � � '----EXISTING METER #334 974 545 '-1- TO REMAIN � -f I • I 400A '-- - EXISTING 400A, 240V-30 SERVICE ENTRANCE RATED FUSIBLE DISCONNECT #1 TO REMAIN .i.� - J = t 4W, BODA IN EXISTING WWTP CONTROL BUILDING LEGEND NEW CONDUIT, WIRING, AND EQUIPMENT EXISTING CONDUIT, WIRING, AND EQUIPMENT 200A-3P I /I EXISTING MOTOR CONTROL CENTER "MCC1" 240V-30, is ECTION -1- -- -- -- -- -- -- -- 1 ���::7 1111 �-\ . ! ;-"'Y"-' ,----'-1 _4 □ A 3P l5EcT10N2 - - - - - - - - - - - - 7sEcT10N3 - 7sEcT10NT - l5ECTION5 - - - - - I EMERGENCY -p-m GENERATOR 120/240V-3¢, 4W I I I • - --- r- )- r QPli] - r- - I-- 1 - >- 20A-3P )-20A-3P I T T I _j_ _j_ -• - - ! )-20A-3P _j_ i---r--I---r- - L )-20A-3P )-20A-3P )-20A-3P )-3 □ A-3P i i i i I I I I I I -r - - L-r--L - I--7 )-100A-3P I )-100A-3P I )-100A-3P )-1OOA-3P 1 I 1 I 1 i VFD I I I VFD I I I I I I I I 1 f I 10 -- -- _l__ f__ : _ J_ I __ I __ I ___ I __ L 01 10 _I __ L_J__L _l __ j___ _J EXISTING 200A, 240V-3¢>---I ➔ - I DISCONNECT #2 FOR MAIN I L.S. FEED TO REMAIN I 200A '--- - J l * g; g; � � ) ) � H � � H � SRP #1 240V-3¢ 4.2 FLA SRP #2 240V-30 4.2 FLA g; � ) � H � CT PUMP 240V-30 4.2 FLA t t 1�1 1 -+ 11 '--J J I I _i 1L1 I 2KW I '--- J UH-1 240V-3¢ 6 FLA I' NORTH I CLARIFIER 240V-3¢ 4.2 FLA I EXISTING 12D/240V-30, 4W 200A MCB PANEL "LPL1" IN EXISTING MAIN LIFT STATION BUILDING (HIGH LEG) ,;--------------------- 1 200A-3P SUB-FEED SOUTH CLARIFIER 240V-30 4.2 FLA t � I 1 1 '-I J I RAS PUMP I I CONTROL PANEL J J --.t ) ) �� �� RASP #3 RASP #4 240V-3¢ 240V-3¢ 6.8 FLA 6.8 FLA BLOWER #1 240V-3¢ 80 FLA 26 1 i � _I_ _j _ ,,.-- � I LP1 I I LP2 I fO -::S_ HP 0 LIGHTING LIGHTING PANEL j PANEL j '--- ,-- '--- - BLOWER #2 240V-30 80 FLA -7 0 PANEL LP1 PANEL LP2 120/240V-30 120/240V-30, 4W, 100A 4W, 100A 0 • •;,; ..l. � -� ONLY IF UV ALT. BID IS ACCEPTED +- ,.-l-,_ 1,3,5 13,15,17 LUGS 16,18,20 19 21 25 I • •- r -- r -7--- - 7 --------- r -- 1 -- i- -- r - 7 I )- )-20A-3P )-20A-3P SEE PANEL )-150A-3P )-4 □ A-3P )-20A-1P )-20A-1P )-20A-1P )-20A-1Pj 0 ' ' I j i i SCHEDULE i FOR 120V (o'\ LOADS 1-V � D J I I I I_ - - - - - - - - - - - - - - - - - - - i J i 1�11 I SCREEfl I T I E � l :: � � 3 � 1FT STATION CONTROL PANEL i I CONTROL L " I I PANEL I I� - r - 7 I I I_1 '--- I - I 0 1 80A-3P 1 80A-3P I I I I NEMA 2 l NEMA 21 I I I L �ARTER START� - _J I � JUNCTION BOX I J: > �� SCREEN MOTOR 240V-3o 6.25 FLA ,Y � T--:f ) ) ) �� r� � 2 � SCREEN PUMP #1 PUMP #2 MOTOR 240V-3¢ 240V-3¢ 240V-3¢ 31.5 FLA 31.5 FLA 6.25 FLA @ -- � NEMA 1 STARTER I 5HP >--.-< AERATOR 24OV-30 15.2 FLA ® EQ BASIN MAG METER 12ov-1• ® EQ BASIN INFLUENT CONTROL VALVE 12ov-1• @ EQ BASIN EFFLUENT CONTROL VALVE 12ov-1• MAIN L.S. SCADA PANEL 12ov-1• I _J 0 LP3 LIGHTING PANEL PANEL LP3 120/208V-3¢, 4W 100A PROPOSED WWTP AND MAIN LIFT STATION POWER DISTRIBUTION ONE LINE DIAGRAM NOT TO SCALE • - REVISIONS 9/1/2023 BID SET (ti 2023 /'>·Iidwe<temEngin�"'"· !nt. 802 \Vc,1 Broac\way Sired P.O. Box 295 Loogootc�. lmli,ma 4755] DATE SEPT. 2023 DESIGN A.F.8. DRAWN C.N.M. Q.C. CHECK R.D.W. PROJECT NUMBER 2022111-00 2 1 21 OF 23 FIL£ NUMBER 43302 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2