Midwestern Engineers, Inc. Plan Preview
• z - � 0 � - , u < � ol :i: D w D D �· w < D � �� ...,_ - �o ,1 �S'. ' 8::- "7 � � �o •• 2 w " �- .. w < - fr Q Q� "o ,u oz 8� a� ON £ .::I 0 • <c MAIN LIFT STATION SCADA NOTES 1. CONTRACTOR SHALL UT I L I ZE OWNER'S EX I STING SCADA SYSTEM INTEGRATOR BY CONTACTING NATHEN BURKHART AT TORIC ENGINEERING AT 317-718-1800 TO PROV I DE SCADA PRICING PRIOR TO BID. PROVIDE NEW SCADA PANEL IN NEMA 1 ENCLOSURE AT EXISTING CONTROL BUILDING WITH THE FOLLOWING FEATURES: A. ALLEN BRADLEY COMPACTLOG I X PLC w/ EXPANSION 1/0 B. CONTROL RELAYS, AS NEEDED C. CONVEN I ENCE RECEPTACLE 0. ENCLOSURE, WALL MOUNT, lYPE 12, PA I NTED STEEL E. FIBER OPT I C PATCH PANEL F. I NTRINSICALLY SAFE BARR I ER, ANALOG, 1 CHANNEL, QUANTllY OF TWO (2) G. INTRINSICALLY SAFE BARRIER, DIGITAL, 2 CHANNEL, QUANTllY OF TWO (2) H. MAIN C I RCUIT BREAKER I. MAPLE SYSTEMS TOUCHSCREEN, 12" J. NETWORK SWITCH, 6 ETHERNET PORTS, 2 FIBER PORTS K. POWER SUPPLY, 24 voe L. TERMINAL BLOCKS, AS NEEDED M. TVSS, 120VAC N. UPS BATTERY BACKUP 0. UL 698A LIST I NG 2. RTU INPUTS/OUTPUTS DIGITAL INPUTS: AERATOR MOTOR RUN STATUS (ON/OFF) AERATOR MOTOR RUN STATUS (ALARM) EQ BASIN INFLUENT FLOW METER TOTAL I ZED FLOW MAIN LIFT STAT I ON PUMP #1 RUN STATUS (ON/OFF) MAIN LIFT STAT I ON PUMP #1 RUN STATUS (ALARM) MAIN L I FT STAT I ON PUMP #1 SEAL LEAK MAIN L I FT STAT I ON PUMP #1 OVERTEMP MAIN L I FT STATION PUMP #2 RUN STATUS (ON/OFF) MA I N L I FT STAT I ON PUMP #2 RUN STATUS (ALARM) MA I N L I FT STAT I ON PUMP #2 SEAL LEAK MA I N L I FT STAT I ON PUMP #2 OVERTEMP MA I N L I FT STAT I ON HIGH LEVEL ALARM NEW FLOAT D I GITAL OUTPUTS: AERATOR MOTOR RUN COMMAND MAIN L I FT STAT I ON PUMP #1 RUN COMMAND MAIN LIFT STATION PUMP #2 RUN COMMAND EQ BASIN I NFLUENT VALVE OPEN COMMAND EQ BASIN INFLUENT VALVE CLOSE COMMAND EQ BASIN EFFLUENT VALVE OPEN COMMAND EQ BASIN EFFLUENT VALVE CLOSE COMMAND ANALOG I NPUT: EQ BASIN I NFLUENT VALVE POS I TION FEEDBACK EQ BASIN EFFLUENT VALVE POS I TION FEEDBACK EQ BAS I N I NFLUENT FLOW METER I NSTANTANEOUS FLOW EQ BASIN LEVEL NEW PRESSURE TRANSDUCER MAIN LIFT STAT I ON WETWELL LEVEL NEW RADAR LEVEL SENSOR ANALOG OUTPUTS: EQ BASIN INFLUENT VALVE POSIT I ON COMMAND (NORMALLY CLOSED, ENERGIZE TO OPEN) EQ BASIN EFFLUENT VALVE POSIT I ON COMMAND (NORMALLY OPEN. ENERGIZE TO CLOSE) ETHERNET: SCREEN CONTROL PANEL F I BER: WWTP CONTROL BUILDING 3. CONTRACTOR SHALL PROV I DE ALL EQUIPMENT, MATERIAL, W I RING ANO PROGRAMMING TO ACCOMMODATE THE NEW 1/0 AS NEEDED FOR A FULLY FUNCTIONING SYSTEM. s is � RELOCATED LIFT STATION PUMP CONTROL PANEL CONTROL W I RING IN CONDUIT TO SCAOA PER 1/0 L I ST PROPOSED AERATOR MOTOR STARTER ' ' ---I LPL1-16,18,2D TO AERATOR AT EQ BAS I N, SEE ONE LINE AND SITE PLAN FOR MORE INFORMATION f------PROPOSED MA I N L.S. SCADA PANEL LPL1-26 ' �(2) 1" CONDU I TS w/ SEAL OFFS I 1- TO PUMP CONTROL PANEL TO n•, RECONNECT 240V-3¢ POWER r (l) 1" CONDUIT w/ SEAL OFF TO MAIN L I FT STATION SCADA PANEL FOR FLOAT CONTROL ,• EX I STING 120/240V-3¢,------I 4W 200A PANEL LPL1 � EXIST I NG UNIT HEATER TO REMAIN EXISTING MOTOR STARTER/DISCONNECT TO REMAIN " (1) 1" CONDUIT w/ SEAL OFF TO MAIN L I FT STATION SCAOA PANEL FOR RADAR LEVEL TO REMA I N (,) AERIAL w/ STRAIN REL I EF n G\------ " 0 ±====r- " 0 ANO CARRIER W I RE FROM eo -<OH!---- eo-�- - eo _J lFI BER FROM WWTP SCADA PANEL I N CONDU I T WWTP SCADA PANEL I ! � CO� NT,_ , ;_ O_L_W_ I_R- I N_G _ I_N _ C_ O_ N� DUIT EX I ST I NG SCREEN CONTROL PANEL TO REMAIN TO SCADA PER 1/0 L I ST I-- -PROPOSED JUNCT I ON BOX, SEE DETAIL SHT. 17 CONTROL W I R I NG IN CONDUIT TO SCAOA PER 1/0 L I ST MAIN LIFT STATION PROPOSED ELECTRICAL PLAN SCALE: ½" = 1'-0" EXISTING 200 AMPERES PANEL ----12ll,i24D. VOLTS LPL1 4WIRE CIRCUIT NO. ITEM FEED __!_ SCREEN 3 5 _J_ HEATER 9 11 HIGH LEG 13 SCREEN CONTROL PANEL SPARE 17 19 EQ BASIN MAG MITER 21 EQ BASIN INFLUENT CONTROL VALVE 23 HIGH LEG 25 EQ BASIN EFFLUENT CONTROL VALVE 27 SPARE 29 HIGH LEG 31 SPARE 33 SPARE 35 HIGH LEG 37 SPARE 39 SPACE 41 HIGH LEG s MCB MAIN CONNECTION MAI� IIFT STATIQt-J BUI.LD.illG.LOCATION WIRE SIZE 12 12 12 12 12 12 12 12 12 12 ') PHASE SURFACE MOUNTING KAIC AMPS 20 20 20 20 20 20 20 20 20 20 S.E.L. POLE cu. POLE AMPS WIRE ITEM FEED BUS SIZE 3 A 1 20 12 RECEPTACLES 8 1 20 12 EXHAUST FAN C HIGH LEG 2 A 1 20 12 PUMP CONTROL PANEL 8 1 20 12 LIGHTS C HIGH LEG 3 A 1 20 12 HEAT TRACE 8 3 40 10 AERATOR MOTOR STARTER C 1 A 1 B 1 20 12 SPARE C HIGH LEG 1 A 1 20 12 MAIN L.S. SCADA PANEL 1 B I 20 12 SPARE C HIGH LEG I A 1 20 12 SPARE 1 B 1 20 12 SPARE C HIGH LEG 1 A 1 20 12 SPARE B SPACE C HIGH LEG ! EXISTING WALL TO BE I BLOCKED UP BY THE OWNER EXISTING CURB TO BE REMOVE0---I BY OWNER TO FLUSH w/ FLOOR CIRCUIT NO 2 4 6 8 10 12 14 _1_6_ _1_6_ 20 22 24 26 28 30 32 34 36 38 40 42 EXISTING 120/240V-3¢,-----j 4W 200A PANEL LPL1 TO REMA I N I �EX I STING UNIT HEATER TO REMAIN TO REMAIN dli � -- ---- ��EXISTING SCREEN CONTROL PANEL TO REMAIN c--- -EXISTING LIFT STAT I ON PUMP CONTROL PANEL TO BE RELOCATED BY CONTRACTOR AS INDICATED ON DRAWINGS EXISTING MAIN LIFT STATION ELECTRICAL PLAN SCALE: ½" = I'-0" • - REVISIONS 9/1/2023 BID SET � 2023 �ljdwc,1m1 Engincc1,. l11c. 801 Wc,t Broadwa� S11w1 P.O. Bo, 195 LO[l�<>ot�e. Indian" 47553 DATE SEPT. 2023 DESIGN A.F.B. DRAWN C.N.M. Q.C. CHECK R.D.W. PROJECT NUMBER 2022111-00 23 23 OF 23 FlLE NUMBER 43300 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2