KNOX COUNTY HIGHWAY ENGINEER/SUPERINTENDENT 1472 N STATE ROAD 67 VINCENNES, IN 47591 P 812-882-2884 COMMISSIONERS KELLIE STREETER, PRESIDENT T.J. BRINK, VICE-PRESIDENT TRENT HINKLE COUNTY COMMISSIONER OFFICE 111 NORTH 7TH ST VINCENNES, IN 47591 PH: 812-660-1407 IN IANA DEPARTMENT OF TRANSPORTATION VINCENNES DISTRICT 3650 SOUTH U.S. 41 VINCENNES, IN 47591 PH 1-800-279-5758 FAX: 1-812-895-7479 DISTRICT PERMIT MANAGER SARA POLMANTER DISTRICT PERMIT INSPECTOR MARIA WALKER PH 1-812-381-4566 PH: 1-812-486-6347 EMAIL: spolmanter@indot.in.gov EMAIL: marwalker@indot.in.gov EMAIL: swincommunications@indot.in gov UTILITIES ELECTRIC: DUKE ENERGY 100 S. MILL CREEK RD. NOBLESVILLE, IN 46062 PH: 317-776-5320 ATTN. DON MCDUFFY EMAiL: dei.dline-coord@duke-energy.com : 1 :1 � N �:�� - �1 M.C VINCENNES, IN 47591 PH· 812-882-5140 ATTN· BRUCE GILL EMAIL: bruceg@winenergyremc.com 1a a,...- EXISTING 2 MG BUNKER HILUARMO TANK No. 4 WATER VINCENNES WATER UTILITY. 403 BUSSERON ST VINCENNES, IN 47591 PH 812-882-6620 ATTN: ANDREW HUTCHISON EMAIL: ahutchison@vinutilities.com SEWER VINCENNES SEWER UTILITY. 403 BUSSERON ST. VINCENNES, IN 47591 PH: 812-316-0273 TREATMENT PLANT ATTN: JOSH MOORE EMAIL: jmoore@vinutilities.com COLLECTION SYSTEM ATTN STAN ECK EMAIL: staneck@vinutilities.com R"- 1t10 , 111-\/0 ,, , I I , '\ • , , , , ;' ii , GAS CENTERPOINT ENERGY (SOUTH) 1800 W 26TH ST. MUNCIE, IN 47302 PH: 765-287-2119 PH 1-800-227-1376 ATTN: JON EASTHAM TELEPHONE: AT&T DISTRIBUTION EMAIL: g09871@att.com WINDSTREAM COMMUNICATIONS 1450 N. CENTER POINT RD. HIAWATHA, IA 52233 PH: 1-800-289-1901 EMAIL: locate.desk@windstream.com ° c ' i I FIBER OPTIC: METRO FIBERNET, LLC ENGINEERING 3701 COMMUNICATIONS WAY EVANSVILLE, IN 47715 PH: 812-213-1050 EMAIL: 811design@metronet.com CABLE TV SERVICES: CABLEONE, INC. OBA SPARKLIGHT (FORMERLY NEW WAVE COMM) PH 877-570-0500 !ZONE 2! EXISTING 2 MG ELEVATED WATER STORAGE TANK No. 5 OF. ELEV. 660.00' PROJECT LOCATION DIVISION I - INDUSTRIAL PARK WATER MAIN EXTENSION SEE SHEETS 3 THRU 7 FOR DETAILS PROJECT LOCATION ESSEX ROAD WATER MAIN EXTENSION SEE DIVISION II FOR DETAILS PROJECT LOCATION MAP SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 U.S. 50 LEGEND: SHEET SCHEDULE DESCRIPTION COVER SHEET OVERALL PROJECT LOCATION MAP, GENERAL NOTES AND SHEET SCHEDULE OVERALL WATER MAP WATER PLAN SHEET WATER PLAN SHEET WATER PLAN SHEET WATER PLAN SHEET BORE PROFILES POINTS OF CONNECTION, CONTROL VALVE ANO METER DETAILS STORMWATER PREVENTION PLAN NARRATIVE TYPICAL WATER DETAILS TYPICAL WATER DETAILS TYPICAL EROSION CONTROL DETAILS QLO US 50 -1- 2"D.I -- EX. WATER MAINS ------ PROPOSED WATER MAINS - DIVISION I PROPOSED WATER MAINS - DIVISION II GENERAL NOTES 1 TOPOGRAPHY SHOWN ON PLAN SHEETS IS INTENDED TO SHOW THE GENERAL LOCATION OF FENCES, CULVERTS, DRIVES. EXISTING UTILITIES, POINTS OF CONNECTION, ETC. HOWEVER; THE EXACT LOCATION AND QUANTITIES SHALL BE VERIFIED AT THE TIME OF CONSTRUCTION. 2. THE HORIZONTAL LOCATION DATA IS BASED UPON THE INDIANA STATE PLANE COORDINATE SYSTEM (WEST ZONE) REFERENCED TO THE 1983 NORTH AMERICA DATUM (NAD83) ELEVATIONS ARE BASED UPON THE 1988 NORTH AMERICAN VERTICAL DATUM (NAVO 88) 3 THE CONTRACTOR SHALL CALL INDIANA UNDERGROUND SERVICES AT 1-800-382-5544 PRIOR TO ANY CONSTRUCTION TWO FULL WORKING DAYS BEFORE CONSTRUCTION IS TO BEGIN 4. THE LOCATION OF EXISTING UTILITIES, ETC. SHOWN ON THESE PLANS ARE NOT THE EXACT LOCATIONS BUT ONLY A GENERAL LOCATION. ALTHOUGH THESE PLANS HAVE ATTEMPTED TO SHOW ALL EXISTING UTILITIES, THE CONTRACTOR SHALL NOT ASSUME ALL EXISTING UTILITIES HAVE BEEN SHOWN. THEREFORE IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO SEE THAT ALL EXISTING UTILITIES WITHIN CONSTRUCTION AREAS ARE CLEARLY MARKED IN THE FIELD PRIOR TO ANY CONSTRUCTION IN THE AREA. 5. EXACT LOCATION OF MANHOLES, LATERALS, CLEANOUTS, AIR RELIEF VALVES, ETC. TO BE DETERMINED AT THE TIME OF CONSTRUCTION. 6. COORDINATION MUST BE MADE WITH THE WASTEWATER COLLECTION SYSTEM MANAGER AT 1-812-881-6590 (CELL), A MINIMUM OF FIVE (5) WORKING DAYS PRIOR TO BEGINNING CONSTRUCTION. 7. EXACT LOCATION OF PROPOSED GATE VALVES, HYDRANTS, FITTINGS, ETC. TO BE DETERMINED AT THE TIME OF CONSTRUCTION. THE CONTRACTOR SHALL BE REQUIRED TO FIELD VERIFY EXISTING STRUCTURE AND PIPE DATA AND REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO ORDERING NEW STRUCTURES. 8 DOWN TIME COORDINATION MUST BE MADE WITH THE WATER UTILITY PRIOR TO WET OR ORY TAPPING WATER MAINS COORDINATE WITH ANDREW HUTCHISON, DRINKING WATER OPERATIONS MANAGER, AT 1-812-882-6620, A MINIMUM OF FIVE (5) WORKING DAYS PRIOR TO WET/DRY TAPPING OF MAINS. 9 PROPERTY LINES, WHERE SHOWN, ARE BASED ON COUNTY PLAT RECORDS. THE SAID PROPERTY LINES ON THESE SHEETS DO NOT REPRESENT THE PROPERTY SURVEYS, BUT ARE ONLY APPROXIMATE LOCATIONS FOR REFERENCE PURPOSES ONLY. 10. IF ANY ARCHAEOLOGICAL ARTIFACTS OR HUMAN REMAINS ARE UNCOVERED DURING CONSTRUCTION, THE CONTRACTOR SHALL STOP ALL EXCAVATION WORK AND CONTACT THE INDIANA DEPARTMENT OF NATURAL RESOURCES, DIVISION OF HISTORIC PRESERVATION AND ARCHEOLOGY AT 1-317-232-1646. NO ADDITIONAL EXCAVATION WORK SHALL BE DONE WITHOUT RECEIVING THEIR APPROVAL. 11 THE CONTRACTOR SHALL AVOID IN CHANNEL WORK (AT STREAM CROSSINGS) DURING THE FISH SPAWNING SEASON (APRIL 1 THROUGH JUNE 30) WITHOUT PRIOR WRITTEN APPROVAL OF THE INDIANA DEPARTMENT OF NATURAL RESOURCES - DIVISION OF FISH & WILDLIFE. 12. THE CONTRACTOR SHALL BE REQUIRED TO IMPLEMENT DUST CONTROL MEASURES (SURFACE WETTING) AS NECESSARY TO MINIMIZE FUGITIVE DUST EMISSIONS 13. IF CAVERNS OR SPRINGS ARE ENCOUNTERED DURING EXCAVATION, WORK SHALL STOP IMMEDIATELY AND THE INDIANA DEPARTMENT OF NATURAL RESOURCES OR THE U.S FISH & WILDLIFE OFFICE SHALL BE CONTACTED CONCERNING PROPER MITIGATION MEASURES 14. ALL SINKHOLES THAT OCCUR IN CONSTRUCTION AREAS SHALL BE LEFT UNDISTURBED ALONG WITH A 25 FOOT BUFFER AROUND THE HIGHEST CLOSED CONTOURS OF THE SINKHOLE. EXISTING VOLUME OF SURFACE DRAINAGE TO SINKHOLES SHALL BE MAINTAINED AND DRAINAGE FROM CONSTRUCTION SITES WILL BE FILTERED OR TREATED PRIOR TO ENTERING A SINKHOLE 15. BITUMINOUS RESURFACING WILL BE PAID BY THE LINEAR FOOT UNIT PRICE SUBMITTED WHEN CENTERLINE OF PIPE IS INSTALLED WITHIN lWO (2) FEET OF THE EDGE OF A PAVED COUNTY ROAD OR TOWN STREET AND RESURFACING IS COMPLETED. BITUMINOUS RESURFACING WILL NOT BE A PAY ITEM BY LINEAR FEET WHENEVER CENTERLINE OF THE PIPE IS INSTALLED MORE THE lWO (2) FEET FROM THE EDGE OF A PAVED COUNTY ROAD OR TOWN STREET HOWEVER, CONTRACTOR(S) WILL BE RESPONSIBLE TO REPLACE ANY ASPHALT DAMAGED IN THOSE AREAS. 16. STONE RESURFACING WILL BE PAID AT THE UNIT PRICE PER TON SUBMITTED WHEN THE WATER MAIN IS INSTALLED UNDER A STONE DRIVE OR ROAD STONE RESURFACING WILL NOT BE A PAY ITEM WHEN THE WATER MAIN IS NOT INSTALLED UNDER A STONE DRIVE OR ROAD. HOWEVER, THE CONTRACTOR(S) WILL BE RESPONSIBLE TO REPLACE ANY STONE TO BRING THE DRIVE OR ROAD BACK TO ORIGINAL CONDITION. LEGEND EXISTING SANITARY SEWER FORCE MAIN WARNING/ LOCATE POST EXISTING AIR RELIEF VALVE LIFT STATION AND VALVE PIT CLEAN OUT e EXISTING SANITARY VALVE 8 SANITARY MANHOLE @ SANITARY GRINDER PUMP --M,-- SANITARY SEWER MAIN -- FIM-- SANITARY FORCE MAIN • • EXISTING 3-WAY FIRE HYDRANT AND VALVE EXISTING 2-WAY FIRE HYDRANT AND VALVE EXISTING FLUSH HYDRANT AND VALVE YARD HYDRANT EXISTING BLOW OFF AND VALVE PRESSURE REDUCING VALVE EXISTING LEAK DETECTION DEVICE WATER METER SPRINKLER HEAD EXISTING GATE VALVE @ EXISTING BUTTERFLY VALVE EXISTING CHECK VALVE EXISTING CURB STOP EXISTING WATER MAIN AND SIZE PROPOSED WATER .../9.._ -- _t_ -- ----� -- ----� -- - - ----9-- - - ---------- - - ---0------ - - - - ---0-- - - PROPOSED WATER MAIN AND SIZE PROPOSED 3-WAY FIRE HYDRANT AND VALVE PROPOSED FLUSH HYDRANT AND VALVE PROPOSED BLOW-OFF AND VALVE PROPOSED WATER METER PROPOSED GATE VALVE PROPOSED BUTTERFLY VALVE PROPOSED CHECK VALVE TELECOMMUNICATIONS TELEPHONE PEDESTAL FIBER OPTIC WARNING / LOCATE POST TELEVISION PEDESTAL BURIED TELEPHONE __ _ , __ _ GAS GAS WARNING / LOCATE POST EXISTING GAS VALVE GAS METER GAS MAIN AND SERVICE LINE SURVEY ♦ SURVEY POINT / BENCH MARK &. SURVEY MONUMENT './ HIGH WATER MARK STORM SEWER ®l lllll STORM STRUCTURES :JT..�< CULVERT TYPE AND SIZE El STORM MANHOLE MISCELLANEOUS • ' e " 0 @ • a _, _ _ ,_ -•--•- -•--•- -•-•- � GD ELECTRICAL 8 • --0"'-- SIGN SATELLITE DISH RIGHT OF WAY MARKER MAIL BOX POST MANHOLE REDUCER CAP TREE WOOD FENCE WOVEN WIRE FENCE ELECTRIC FENCE CHAIN LINK FENCE HOUSE HOUSE TRAILER ELECTRICAL PEDESTAL ELECTRICAL METER LIGHT POLE UTILITY POLE WITH GUY BURIED ELECTRIC OVERHEAD ELECTRIC OVERALL PROJECT LOCATION MAP, GENERAL NOTES AND SHEET SCHEDULE REVISIONS 08/01/2025 BID SET C 2025 Midweskm En_gineers. Inc. 802 West [lrn:tdway Street P 0. Box 2'}5 Loogootec. [mliana 47553 DATE AUGUST 2025 DESIGN E.K.P. DRAWN M.M.C. a.c. CHECK PROJECT NUMBER 2023054-00 2 2 OF 13 I FllE NUMBER I 45109 Do Not Use Plan Previews for Take Off
RkJQdWJsaXNoZXIy NjAyODM2