Midwestern Engineers, Inc. Plan Preview
WATER METER AND PRESSURE REDUCING VALVE COMBINATION AS SHOWhl SHALL BE INSTALLED Oi� ALL SERVICES WHERE STATIC PRESSURE EXCEEDS 75 PSI ¾' OR 1 "PRESSURE REDUCING �- -- VALVE MODEL 9R4 WITH A --i·>-.J REDUCED OUTLET PRESSURE RANGE OF 15 ,·o 150 PSI AS MANUFACTURED BY WILKINS (A ZURN COMPANY) OR ENG!NEER APPROVED EQUAL ANGLS DUAL CHECK VALVE YOKE WITH BRACING EYE-----· SEE SPECIFICATIONS -- METER YOKE TO EXTEND THRU WALL -· --WITH¾" COPPER DUAL PURPOSE OUTLET CONNECTION / I I \ I I I ' I • f118H STRENGTH POLYPRO�V��NS METER BOX FRAME Al'lD COVER 20' I.D. HOPE METER PIT 30'' DEEP SEE SPECIFICATiOi\S - ANGLE BALL VALVE BRASS NIPPLES METER COPPER SETTER SEE SPECIFICATIONS METER SEE SPECIFICATIONS :"".:,,.._,,,r-+-- ¾" OR 1" HOPE SDR-9 CTS SERI/ICE FROM MAIN c;,----,f--- 16" LONG SCH. 60 RIGID PVC PIPE BRACE,½" DIA. STANDARD I.D. HDPE 1\/�TER P'T 30" DEEP SEE SPECIFICATIONS PRESSURE GAUGE -� STANDA'-'iD COPPER METER IDLER -WITH 0-20J PSI TAPPED PRESSURE GAUGE. GAUGE SHALL BE o;: MATERIAL SUITABLE FOR GROUND WATER COc-.JDITIONS. TO DETERMINE EXACT FLOW LOSSES,%" x¾" WATER METER SHALL BE INSERTED IN PLACE OF IDLER FORD No. W-82-12 WITH FULL PORT WING BALL STOPS ON BOTH ENDS AND BRACII\G EYE OR ENGINEER APPROVED EQUAL ¾ " TYPE K SERVICE TUBE --- ------------ =- )) 11 I I /,f'�/, � i--- 6" PVC SDR·35 PIPE ··· GATE VALVE WATER MAIN i6" LONG R!GJD PVC PIPE BRACE.J;i" DIA. '-- D.I. TEE PRESSURE REDUCING VALVE AND \!\/ATER METER LEAK DETECl-lON DE'✓iCE INSTALL VALVE WITH \ PLUG AND CONG. •HRUST BLOCK FOR HYDRANT AT END OF UNE CONC. THRUST BLOCK �YJ I " I I I I I I • I '0 � NOTE: VALVE BOXES SHALL BE SCREW TYPE 2-PIEC:c OR 3-PIECE CAST IRON WITH CAST IRON L!D IN ALL S:ONE, ASPHAlT OR CONCRETE SURFACE AREAS ANCHOR COUPLiNG j FLUS H HYDRANT i WITH MECHANIC AL JOINT CONNF.CT' ON .rr:� NOTE: USE R.EDUCII\IG TEF IF REQUIRED FLUSH HYDRANT CONNECTION APPROX. ?'.Q'' OR AS , C'RECTED f!Y ENGINEER __________ , ______ ,_,_ VALVE BOX -· \ COVER \ �� FLUSH HYDRANT SEE SPECIFICATIONS ANCHOR cm;pu:�G on --� FOS:ER ADAPTER VALVE WITH MECHANICAL JOIN• RESTRAINED TO PIPE SY USE OF MEGALUG BY !:BM IRON, iNC. c_; �- '" �] C :::tt-, ls � GATE VALVE, IF REQUIRED STONE CONCRETE THRUST BLOCK - >'fi. , ;' NOTE: BLOW-OFF VALVE &ACCESSORIES FOR 12" MAINS &SMALcER SHALL BE SAME SIZE AS MAIN. BLOW-OFF VALVE AND ACCESSORIES FOR MAl�JS OVER 12 " SHALL BE 12" DI ?IPE FROM MAINS. ALL FITTINGS & PIPE SHALL SE MECHANICAL JOINT. VALVE BOX --.____ COVER � ALUMINUM __.../ VALVE BOX TOP 6"PVC----,,_, SOR-35 PIPE D.I. TEE #5 REBAR 8" O,C --· LONGITUDINAL ONLY r SUTTER VALVE I i- lli6GAUGE I ,,- GRADE - MEGALUG 1 ,,,,,,.- PERFORATED¼" OPENING, ! / TOTAL OPENING AREA NOT ••l1Jti! TO BE MORE THAN 1 SQ. INCH I >"- : Jir--- \MASHED #5 STON:: •'°'""" 18" AROUND PIPE D .i'< "' MEGALUG · :� PLACE CONC BETWEEN . � .- PIPE AND UNDiSTURBED I_. ANCH:JR EARTH COUPLING BLOW-OFF \/ALVE DETAIL --- D.L OR PVC MAIN LINE PIPE (TYPICAL) 11------- BELL RESTRAINT HARNESS MEGALUG BY EBAA IRON, INC. REQUIRED FOR 2 JOINTS BEYOND Fl-:-TING /VALVE EACH WAY VALVE WITH MECHANICAL JOINT RESTRA!NED TO p1PE BY USE OF MEGALUG BY EBAA IRON, INC. � . / · :,c . v,, 1 1 ·:>'>::.>>':: ',(;:�•·� '.";��:%>;;., '-;_'.-:',•-.(,.--, )�t 1 , ,, BELL RESTRAINT HARNESS MEGALUG BY EBM IRON INC, REQ'D FOR 2 cOINTS BEYOND FITilNG, EAC!; WAY I PER TABLE lr>J SPECS. , a VALVE BOX ------ COVER � 6' ' PVC ----1 SDR-35 PIPE NOTE: VALVE BOXES SHALL BE SCREW TYPE, 2·PIECE OR 3·PIECE CAST IRON WITH CAST IRON LID IN ALL STONE, ASPHALT OR CONCRETE AREAS. VALVE BOX �� COVER 1C::]" 116REINFORCING RODS (2 REQUIRED) 0 , 0 0 0 '---' o '"" r-.=-i o . ' BUTTERFLY VALVE MUELLER LINESEAL XP (250 PSI), THE HENRY PRATT OR ENGINEER APPROVED EQUAL ' '- CONC. PAD MIN. SIZE 4'x4' x4' THICK --' SET FLLiSH WITH PAVEMENT OR GROUND SURFACE 6" PVC SDR-35 PIPE BUTTERFLY VALVE DETP,IL to D.I. FITTING WITH MECHAJIIICAL JOINT RESTRAINED TO PIPE BY USE OF A MEGALUG BY EBAA IRON, INC. . ,-s,,v;;:_::f 0' ; .;u. ll.,_�r;:[l TABLE IN SPECS, l�]�l :P O f z r BELL RESTRAINT HARNESS MEGALUG 3Y EBA-'\ IRON, INC. REQ'D FOR 2 JOINTS BEYOND FITTiNG. EACH WAY • -� , 0 a,• .�':: -·. -1 ' ANCHOR COUPLING OR FOSTER ADAPTER , , "•.·•. � :, - '-� .:· ,., l.-· -·--� - , ,_ STONE BED y�"'"½"-..¾W,,,Mt � '. *'"��.7'.,;,._ ,,,�:-"--- �� j STONE BED APFROK 7'·0'' CR AS DIRECTED BY ENGINEER BRANCH CONNECTlON FOR DUCTILE, CAST IRON OR PLASTIC PlPE VERTICAL • SEE SPECIFICATIONS HORIZONTAL TYPICAL THRUST BLOCK DETAIL NOTE: VAL\IE BOXES SHALL BE SCREWTYPE, 2-PIECE OR 3·PIECE CAST IROI� WITH CAST IRON LID IN ALL STONE, ASRHALT OR CONCRETE AREAS. VALVE BOX 1rl;;J 11 / COVER 1 ALUMINUM VALVE BOX TO TOP 6"PVC ______, SDR-35 PIPE GATE VALVE � MAIN "'1 D.i. TEE ANCHOR COUPLING - 2'-0" V!lf'J. 6' 'D.I. PIPE ,_____ FIRE HYDRANT SEE SPECIF CAT,Ol,S PRECAST C:JNC . SLABS OR STONE W EDGE BETWEEt>; HYDRANT A.ND flRi\� FACE OF TREl',i C:-,l 6CJBIC FEET OF WASHED GRAVEL OR WASHED STONE i/5 HYDRAN"T SETTING □ E-1 AIL VALVE BOX COVER GRADE� B" OR LESS 1 0" OR 12" 16" AND UP -,-- ------.,.,,,.,,,- , ---,-, -+- 1 , � 3 '<"; 1 -r 8 '.,.;; M :::_: A · ' �· · � '7 - � - --- •1 ' I • UL,.... l�::.::::: -:- . ==r ...=:!J " --, , �·- "OPEN LEFT' oR �c:;---,--k: 1 , / "OPi'�J R!GHT" l e" . : ['(;! : , , 0 / INDICATOR AlUMIN . JM -- 'I�. !I, : ·- \/Al\lE BOX 1 '-' ------ DUCTILE iRON ' ' ' ,!f TI OPERAT:NG NUT , - - 1 �--- l wao:o --==== -_ · . 1 I ' . I 1 _ � _ - 'i SIZE I : l ti:l i VR8 VR-D VR-E STEEL ALIGl\;MENT WASHER VALVE ,=-11 :,,_I �i BOX ½" LE . "'S _ _If' ;:,I fil� A-10'8 COLD ROLLED STEL 1----i-c;----l fHANw • "'T STEM AS MANUF. BY GENEGO VALVE 1.D. '.Q I PRODUCTS OR ENGINEERED 6' ' PVC ---SDR·35 PIPE WELDED - ¾"'STEE.. PIN AT EACH END SPOT WELD I VA a VE _,A SET SCREW VALVE STEM EXTEf\JSION i'=' : APPROVED EQUAL ,� z · DUCTILE IRON SOCKET 100" 1.25" 1.50" STAINLESS STEEL TAPPING ,EE WITH STAINLESS STEEL FLANGED OUTLET MUELLER #i"1·3C4SS OR ENGINEER APPROVED EQUAL EXISTING MAIN � EXISTING MAIN r TAPPING G . ATE VAlllE MUELLER FLxr✓iJ OR ENGINEER APPROVED EQUAL NEW MAIN WET TAP CONNECTION TO EXISTING �/lAIN CUT-IN SLEEVE ---_ MUELLER #H·840 \ OR ENGINEER \ APPROVED EQUAL EXISTING MAIN / GATE VALVE MUELLER FLxMH OR ENGINEER APPROVED EQUAL EXISTING MAIN CUT-IN SLEEVE FOR VALVE OR TEE TO EXISTING MAIi\! I I I j REVISIONS >''if¾ '½,'' .. - _,;;,,,,,, \� .;::.,,/t frra� -, 'la.�.,, ,,.., bi BID SET � :OZ.i \!ici,n."�tc·rn Et1G'.;1�er,. Inc. SO_:> \Ve',! Brom\1>,.1, ',u·oc,�t PO. BP.\ _:,95 Luo;;u,�\<'t, �cdi,ni:i -t'7''.':.:- DA1E 2023 , 01:SIGN R.D.W, DRAW<'N K.J.G. Q.C. CHECK PROJECT NUM�ER 2023063-·00 9 CF _1 _1 _ RU: NUMBER 43329 I I I I ·;, I I Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2