LEGEND 1) 12" MAlN SUCTION 2) 2" AUTOMATIC AIR RELEASE VALVE 3) 2" BAU_ VALVE 4) HOSE BIBB 5) 4" GATE VALVE 6) 4" RESTRAINED FLANGED ADAPTER 7) 4" MAG METER B) B"x4" CONCENTRIC REDUCER 9) 2 1/2" METER TEST PORT 10) 8" SUCTION HEADER 11) 2" INSPECTION PORT 12) 6" BUTTERFLY VALVE • 13) 6" ELASTOMER PIPE CONNECTOR 14) 6"x5" ECCENTRIC REDUCER • s' 15) 20 HP PUMP 16) 6"x3" CONCENTRIC REDUCER - � 17) 6" RESTRAINED FLANGED ADAPTER 18) 6" CHECK VALVE 19) 6" ELASTOMER PIPE CONNECTOR (FUTURE) 20) 6"x5" ECCENTRIC REDUCER (FUTURE) 21) 20 HP PUMP (FUTURE) 22) 6"x3" CONCENTRIC REDUCER (FUTURE) 23) 6" RESTRAINED FLANGED ADAPTER (FUTURE) 24) 6" CHECK VALVE (FUTURE) 25) 8" DISCHARGE HEADER 26) 3" BUTTERFLY VALVE 27) 3" CONTROL VALVE 28) 8" BUTTERFLY VALVE 29) 8" COUPUNG 30) 8" CHECK VALVE 31) 12" MAIN DISCHARGE 32) 4" FLOOR DRAIN 33) 1 TON HVAC UNIT 34) 1 TON CRANE RAIL " ® @ Cl] @ � " ' � CJ� � [I] ® @ @ ® � @ @ = ISOMETRIC VIEW @ 11 @ © @ @ 11 11 [2] 11 N - i@ ' i CJ@ � � @ [2] @ I I i @ i @ BUILDING PLAN VIEW [I] ELECTRICAL POWER, SERVICE AND CONTROL PANELS SHALL BE WALL MOUNTED ON SUPPORT CHANNEL AND TO MEET NEC 110-26 REQUIREMENTS EACH PANEL SHALL HAVE A COMPLETELY UNOBSTRUCTED 42" ACCESS AREA IN FRONT OF THE PANEL; SUCH AREA TO EXTEND FLOOR TO CEILJNG. [l] PIPING MUST BE ARRANGED THAT A MINIMUM 27" WIDE UNOBSTRUCTED WALKUP SERVICE SPACE ON THREE SIDES OF EACH PUMP IS PROVIDED WITHOUT CLIMBING OR STEPPING OVER ANY DEVICE OR PIPING. [3J OPENING LOCATIONS ARE lYPICAL. CONTRACTOR IS TO CONFIRM ACTUAL SIZE AND LOCATION WITH BOOSTER STATION MANUFACTURER. NOTE: THIS DRAWING IS FOR INCLUSION IN BID DOCUMENTS @ COPYRIGHT EFI-Solut!ona-2025 TYPICAL PIPE SUPPORT BUllDINC W/,1..L Nl nOdTaEl,l l nnguc ovnofmn x f o r UNOER SUTlON TYPICAL GROUT DETAIL oESiGNED or, JH W[CI-WOC.',l om:m, EILCTIOCAL t------,OY P.M./C.E., CHECl(![l llY! Dl"1flN llY! MF SCAL.E;N.T.5. P.O. BOX nJ • CflflRAIJI,, l.l.N)tS 0�1 • 61��\J:il BOOSTER PUMP STATION SOUTHERN MONROE WATER .KIii R£J" NO. 5500 -. NO. P-5500-B-001. DESIGN CRITERIA CONTROLS TELEMETRY PANEL (NOT BY STATION MFR.) POWER SERVICE: 480 VOLTS, 3 PHASE, 60 CYCLE PUMP DATA TYPE PUMP: CAPACITY: SIZE: MOTOR: NOTE: HORIZ., CLOSE CPLG., END SUCTION 1 & 2 (3 FUTURE) 400 G.P.M. AT 102 FEET T.D.H. 4" X 5" X 7" 40 H.P., 3600 R.P.M. PROPOSED BOOSTER STATION No. 3 - "POINTE BOOSTER STATION" OWNER SHALL PROVIDE THE BOOSTER STATION THRU OFFSITE MANUFACTURER AND SHALL SHIP COMPLETED STATION TO THE SITE. CONTRACTOR SHALL BE REQUIRED TO INSTALL BOOSTER STATION IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. BOOSTER STATION DETAILS • - REVISIONS FOR INFORMATIONAL PURPOSES ONLY BID SET C> 1025 8M0i2d wWeesst et rBnrEo .n, dgwi n1e1 yt rS: st.r el nect . PLo0o.gBoootxee2.9I5ndian:, -'17553 DATE JUNE 2025 DESIGN RDW DRAWN MMC Q.C. CHECK EKP PROJECT NUMBER 2023076-00 9 9 Df 16 I FlLE NUMBER 44980 I Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2