Midwestern Engineers, Inc. Plan Preview
z 0 z 0 0 0 o' < w 0 0 w < w 0 w z > 0 c :5 u ;Ii > > ! le < � ��I Q -;i; ,9 Q � gi � a- "' ...... a:,� > lo§ - .w H <1ltii � ..: Q -I � -c • 9, Q "o 00 U wz z -, <i � 2,, 0N s� <c UTILITIES ELECTRICAL Utilities Dist of Western Indiana R.E.M.C. PO Box 427 1666 W. SR. 54 Loogootee, IN. 47553 Shane Smith 812-384-4446 Duke Energy 390 N Main Street Martinsville, IN. 46151 Tim Umbaugh 765-349-4012 WATER: Town of Clay City 800 Front St P.O. Box 87 Clay City, IN 47841 Chuck Strunk 812-939-2345 SEWER: Town of Clay City 800 Front St. P.O. Box 87 Clay City, IN 47841 Chuck Strunk 812-939-2345 TELEPHONE: AxiaTP 151 North Delaware Stree, Suite 1750 Indianapolis, IN 46204 317-489-5544 CABLE: JOINK LLC. 834 S. 1oth St Terre Haute, lN. 47807 Jackie McDonald 812-234-5100 GAS: Vectren 1800 W 26th St Muncie, IN. 47302 Jon Eastham 765-287-2119 HOLEY MOLEY SAYS, "CALL BEFORE YOU DIG" (TWO WORKING DAYS PLEASE) 1-800-382-5544 INSl0£ I� 1-800-428-5200 FROMOUTSIDE� EXISTING TANK No 1 75,000 GALLON ELEVATED TANK O.F. ELEVATION 723.63 6 ,, PROPOSED WATER �-PROPOSED WATER MAIN & SIZE " PROPOSED GATE VALVE EXISTING WATER ,c,.£_EXISTING WATER MAIN & SIZE e EXISTING GATE VALVE GENERAL TOPO @ SIGN • SATELLITE DISH o PROPOSED BUTTERFLY VALVE @ EXISTING BUTTERFLY VALVE t EXISTING BLOW OFF VALVE t EXISTING FLUSH HYDRANT a RIGHT OFWAY MARKER ,o MAIL BOX � PROPOSED BLOW OFF VALVE � PROPOSED FLUSH HYDRANT i PROPOSED 2 WAY HYDRANT "$° PROPOSED 3 WAY HYDRANT f EXISTING 2 WAY HYDRANT t EXISTING 3 WAY HYDRANT o POST/BOLLARD 8 SANITARY MANHOLE 8 STORM MANHOLE • PROPOSED HYDRA STOP • EXISTING HYDRA STOP ®TREE • PROPOSED INSERTA VALVE t PROPOSED LEAK DETECTION � EXISTING INSERTA VALVE � EXISTING LEAK DETECTION @ EXISTING METER WOOD I BARBED WIRE FENCE ELECTRIC/ CHAINLINK FENCE Ill PROPOSED/ RELOCATED METER g PROPOSED PRV l EXISTING PRV � HOUSE I H.T. I HOUSE TRAILER s PROPOSED CHECK VALVE * PROPOSED CUT AND CAP 0 EXISTING CHECK VALVE Y.H. '( EXISTING YARD HYDRANT ---m-- BURIED TELEPHONE CABLE -¢- LIGHT POLE SHEET 2 3 4 5-6 7 8 w EXISTING CORP. STOP �POWER POLE/ GUY WIRE GAS MAIN -·-·-·-·- TELEPHONE -•-·-·- FIBER OPTIC SHEET SCHEDULE OVERHEAD ELECTRIC DESCRIPTION COVER SHEET � SURVEY CONTROL POINT & SURVEY MONUMENT "' ELECTRIC METER PROJECT LOCATION MAP, SHEET SCHEDULE AND GENERAL NOTES il '1J7 GAS VALVE/ GAS METER EXIST(NGOVERALL SYSTEM MAP TANK SITE PLAN TYPICAL TANK DETAIL SHEETS EXISTING TANK No. 1 DEMOLITION PLAN ELECTRICAL PLAN CLAY COUNTY COMMISSIONERS BRYAN ALLENDER MARTY HEFFNER PAUL SINDERS 609 E. NATIONAL AVE., ROOM 105 BRAZIL, IN 47834 PH 812-448-9008 INDIANA DEPARTMENT OF TRANSPORTATION CRAWFORDSVILLE DISTRICT 41 WEST 300 NORTH CRAWFORDSVILLE, IN 47933 PH. 855-INDOT4U (463-6848) FAX: 765-364-9226 GENERAL NOTES 1 TOPOGRAPHY SHOWN ON PLAN SHEETS IS INTENDED TO SHOW THE GENERAL LOCATION OF FENCES, CULVERTS, DRIVES, EXISTING UTILITIES, POINTS OF CONNECTION, ETC. HOWEVER; THE EXACT LOCATION AND QUANTITIES SHALL BE VERIFIED AT THE TIME OF CONSTRUCTION. 2. THE HORIZONTAL LOCATION DATA IS BASED UPON THE INDIANA STATE PLANE COORDINATE SYSTEM (EAST ZONE) REFERENCED TO THE 1983 NORTH AMERICA DATUM (NAD83) ELEVATIONS ARE BASED UPON THE 1988 NORTH AMERICAN VERTICAL DATUM (NAVO 88) 3 4. THE CONTRACTOR SHALL CALL INDIANA UNDERGROUND SERVICES AT 1-800-382-5544 PRIOR TO ANY CONSTRUCTION TWO FULL WORKING DAYS BEFORE CONSTRUCTION IS TO BEGIN. THE LOCATION OF EXISTING UTILITIES, ETC SHOWN ON THESE PLANS ARE NOT THE EXACT LOCATIONS BUT ONLY A GENERAL LOCATION. ALTHOUGH THESE PLANS HAVE ATTEMPTED TO SHOW ALL EXISTING UTILITIES, THE CONTRACTOR SHALL NOT ASSUME ALL EXISTING UTILITIES HAVE BEEN SHOWN. THEREFORE IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO SEE THAT ALL EXISTING UTILITIES WITHIN CONSTRUCTION AREAS ARE CLEARLY MARKED IN THE FIELD PRIOR TO ANY CONSTRUCTION IN THE AREA. 5. EXACT LOCATION OF GATE/BUTTERFLY VALVES, HYDRANTS, FITTINGS, ETC TO BE DETERMINED AT THE TIME OF CONSTRUCTION. 6. DOWN TIME COORDINATION MUST BE MADE WITH THE WATER UTILITY PRIOR TO WET OR DRY TAPPING EXISTING WATER MAINS. COORDINATE WITH THE OWNER, A MINIMUM OF FIVE (5) WORKING DAYS PRIOR TO WET/DRY TAPPING OF EXISTING MAINS. 7. PROPERTY LINES, WHERE SHOWN, ARE BASED ON COUNTY PLAT RECORDS. THE SAID PROPERTY LINES ON THESE SHEETS DO NOT REPRESENT THE PROPERTY SURVEYS, BUT ARE ONLY APPROXIMATE LOCATIONS FOR REFERENCE PURPOSES ONLY. PLAN SHEET INFORMATION REVISIONS BID SET @ 2024 Midwcslem Engineers. Inc. 802 West Broadw,1y Saec1 P.O. Box 295 Loogootee. !ndian,i 47553 DATE JAN. 2024 DESIGN R.D.W. DRAWN K.J.G. /._ M.K.W. Q.C. CHECK PROJECT NUMBER 2023108-00 2 2 OF 8 FILE NUMBER 53836 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2