Midwestern Engineers, Inc. Plan Preview

MARSHALL COUNTY COMMISSIONERS 112 W. JEFFERSON ST, ROOM 205, PLYMOUTH, IN 46563 PH: 574.936.4863 STAN KLOTZ, PRESIDENT MIKE BURROUGHS, VICE PRESIDENT KEVIN OVERMYER INDIANA DEPARTMENT OF TRANSPORTATION LAPORTE DISTRICT, 315 E. BOYD BLVD, LAPORTE, IN 46350, PH 219 325.7434 UTILITIES ELECTRIC: INTERNET: NIPSCO ELECTRIC 724 HOHAM DRIVE PLYMOUTH, IN 46563 WATER, SANITARY, STORM WATER, STREET DEPT. CULVER WATER DEPARTMENT 200 E. WASHINGTON STREET CULVER, IN 46511 PH: 574-372-1137 CONTACT BOB PORTER CABLE: FOURWAY.NET PH 574 292.3943 MEDIACOM, LLC 1907 S. HEATON ST KNOX IN. 46534 PH: 1-855-755-2225 12700 4Z ROAD PLYMOUTH, IN 46563 CONTACT: GAS: NIPSCOGAS 724 HOHAM DRIVE PLYMOUTH, IN 46563 PH 574-372-1137 PH 800.733.0062 MEDIACOM, LLC 215 W. WALNUT STREET WATSEKA, IL 61523 CONTACT: GARY GUDEMAN PH 844.274.6753 GENERAL NOTES= 1 TOPOGRAPHY SHOWN ON PLAN SHEETS IS INTENDED TO SHOW THE GENERAL LOCATION OF FENCES, CULVERTS, DRIVES EXISTING UTILITIES, POINTS OF CONNECTION, ETC. HOWEVER, THE EXACT LOCATION AND QUANTITIES SHALL BE VERIFIED AT THE TIME OF CONSTRUCTION 2 THE HORIZONTAL LOCATION DATA IS BASED UPON THE INDIANA STATE PLANE COORDINATE SYSTEM (WEST ZONE) REFERENCED TO THE 1983 NORTH AMERICAN DATUM (NAO 83) ELEVATIONS ARE BASED UPON THE 1988 NORTH AMERICAN VERTICAL DATUM (NAVO 88). 3 THE CONTRACTOR SHALL CALL INDIANA UNDERGROUND SERVICES AT 811 PRIOR TO ANY CONSTRUCTION TWO FULL WORKING DAYS BEFORE CONSTRUCTION IS TO BEGIN. 4. THE LOCATION OF EXISTING UTILITIES ETC. SHOWN ON THESE PLANS ARE NOT THE EXACT LOCATIONS BUT ONLY A GENERAL LOCATION ACCURACY IS NOT GUARANTEED. ALTHOUGH THESE PLANS HAVE ATTEMPTED TO SHOW ALL EXISTING UTILITIES, THE CONTRACTOR SHALL NOT ASSUME ALL EXISTING UTILITIES HAVE BEEN SHOWN. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SEE THAT ALL EXISTING UTILITIES WITHIN CONSTRUCTION AREAS ARE CLEARLY MARKED IN THE FIELD PRIOR TO ANY WORK. CONTRACTOR SHALL BE RESPONSIBLE TO PROTECT ALL UTILITIES, INCLUDING THE HOLDING OF POWER POLES, DURING CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER. 5. ANY DAMAGE TO EXISTING UTILITIES DURING CONSTRUCTION SHALL BE REPAIRED BY CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 6. THE CONTRACTOR MUST COORDINATE WITH THE UTILITY PRIOR TO SHUTTING DOWN A WATER MAIN, SEWER MAIN AND I OR LIFT STATION. A MINIMUM OF 7 - DAYS NOTICE IS REQUIRED. DOWN TIME SHALL BE KEPT TO A MINIMUM. BYPASS AND BYPASS PUMPING PLANS SHALL BE REVIEWED BY THE OWNER AND ENGINEER PRIOR TO IMPLEMENTATION. 7. PROPERTY LINES, WHERE SHOWN. ARE BASED ON COUNTY PLAT RECORDS. THE SAID PROPERTY LINES ON THESE PLANS DO NOT REPRESENT PROPERTY SURVEYS. BUT ARE APPROXIMATE LOCATIONS FOR REFERENCE PURPOSES ONLY CONTRACTOR SHALL COORDINATE WORK ON PRIVATE PROPERTY PER THE CONTRACT DOCUMENTS. 8 THE CONTRACTOR SHALL BE REQUIRED TO IMPLEMENT OUST CONTROL MEASURERS (SURFACE WETTING) AS NECESSARY TO MINIMIZE FUGITIVE OUST EMISSIONS. WATER TREATMENT PLANT- GENERAL LOCATION MAP DRAWING INDEX EXISTING WATER TREATMENT PLANT: 1 TITLE SHEET, PROJECT LOCATION MAP 2 UTILITY INDEX, GENERAL NOTES AND DRAWING INDEX 3 SITE IMPROVEMENTS PLAN 4 DEMOLITION FLOOR PLAN 5 IMPROVEMENTS FLOOR PLAN 6 SECTIONS 7 SECTIONS 8 PROPOSED ELECTRICAL SITE PLAN 9 EXISTING POWER DISTRIBUTION ONE LINE DIAGRAM 10 PROPOSED POWER DISTRIBUTION ONE LINE DIAGRAM 11 ELECTRICAL FLOOR PLAN PROPOSED WELLHOUSE 'C' 12 PLANS, SECTIONS AND DETIALS 13 ELEVATIONS AND DETAILS 14 SECTION AND DETAILS 15 DETAILS 16 ELECTRICAL FLOOR PLAN SHEET LEGEND - - �-- - Existing Water Main and Size @ :<:- Water Meter o <' c; Existing Structure 0 " Sanitary Sewer Manhole 0 '- "' □ Catch Basin 0 Storm Sewer Manhole Bm Curb Inlet O \,16 Mail Box x,· 0 G © Gas Meter � Utility Pole Guy Anchor (71 � Lamp Post 0 Utility Pole <1.'"� [:::::{{J Landscape Q Power Pole c===:::i Drainage Culvert M Gas Valve SCALE: NONE □� Telephone Pedestal ,0 '"' it Existing Light Pole 0"' D Existing Buried Tel. Vault '" �% 9 Stop Sign 4.>,; 9 Information Sign 0 f� Street Sign --Bc-- Communication Line .fi. Existing Fire Hydrant REVISIONS BID SET @2025 J\lid"e5tcrn f'nsi11eer�. l�c. P80.O2.WBeo�x12B9r5oadway .Street LoO."OOtee. lndi"na 47553 DATE Ma)'., 2025 DESIGN GAS Gas Main M.M.S. RW --------------- Highway Right-of-Way DRAWN D.A.P. Q.C. CHECK FD Fiber Optic Phone Line A.E. PROJECT NUMBER BE Buried Electric Line 2023115-01 SAN Sanitary Sewer Line STM Storm Sewer Line HE Existing Overhead Electric 2 APP. RNv Apparent Right-of-Way 2 OF 16 FILE NUMBER 44810 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2