Midwestern Engineers, Inc. Plan Preview

- EXISTING VALVE VAULT EXISTING SITE (LOOKING SOUTHEAST) GRASS I I I I \ I / / I \ / ' / \ ELIXF.T4S" TFA/MTITOON ENXo.. 5 / / / / \ \ \ \ ' / / / I I I I I J I I I \ \ ' ,--,--,--,--,--,--,--,--, ---- '- ' '- I / - STONE I I I I I ! \ I I I \ \ '- '- I I I I I I I I \ \ \ '- '- I I EXISTING SITE (LOOKING NORTHWEST) I I ERXIMISETLINEGV: V4A9L0V.9E5'VAULT BTM ELEV: 486.93' ( I I I / ✓ REXI MISETLINEGV: W49E2T.6W0'E L L BTM ELEV: 477.22' EXISTING VALVE VAULT EXISTING SITE (LOOKING NORTH) • �FROMEX. < MH1105 • 1 4C- I1T0Y- 2O5 F- 3 W0 4A- 0S4H5I .N0 G0 0T- O0 1N7 I EX. MH1444 I ----------RIM ELEV: 490.51' e-- I I NN V V . . 4 4 8 8 1 1 . . 9 81 1 ' ' ( ( O IN U ) T) :·A·. �w . EE QX IUSITPIMN GE NETL ERCA CT RKI C A L GRASS / / I I I I I I I I 10 / / 5 0 '••� .,,--/// --EXISTING TRANSFORMER "'· / � / / ----------""'<¼�,-,.-----;I----- � EX. MH1442 RIM ELEV: 489.92' IINNVV.. 447799..12T2' ((IONU) T) STONE I I I I 10 EXISTING VALVE VAULT 1 3 AIR RELEASE VALVE BYPASS PUMP CONNECTION L ____ .J EXISTING STEEL VALVE VAULT BYPASS PUMP CONNECTION VALVE VAULT PLUG VALVE / •JI .... REPLACE EXISTING PUMPS 4" PLUG VALVE (TYP.) WITH NEW PUMPS. SEE SPECS 4" CHECK VALVE (TYP.) N 0 PLAN 4" PLUG VALVE (TYP.) . . . AIR RELEASE VALVE f TOP OF VALVE VAULT ELEV. 490.95' • 4" F/M OUTLET PIPE (NE) TOP 487.80' BTM OF VALVE VAULT ELEV: 486.93' NOTES: EXISTING STEEL VALVE VAULT VALVE VAULT 4" CHECK VALVE (TYP.) ELE 4" FORCE MAIN ELEV. 490.70' . REMOVE EXISTING PUMPS, PUMP BASES, VERTICAL DISC. PIPES, r�1-:,1--.1:1, FITTINGS, AND APPURTENANCES FROM EX. WET WELL. PROVIDE AND INSTALL TWO (2) NEW SUBMERSIBLE PUMPS, PUMP BASES, 2" S.S. LIFTING RAILS, S.S. CHAINS, 4" D.I. CL 350 PIPE, D.I. FITTINGS, AND RELATED EQUIPMENT PER THE SPECIFICATIONS. WET WELL WET WELL EXISTING WET WELL 8" INLET PIPE N INV. 481.85' EXISTING 6-0' DIA. CONC. WET WELL 8" INLET PIPE SE !NV. 478.75 36"x36" HATCH .. I ,. .. TOP OF STATION f ELEV. 492.60' GRADE VARIES ELEV. 490.49' - 490.90' EXISTING 6-0' DIA. CONC. WET WELL 8" INLET PIPE (N) FROM MH 1444 INV. 481.85' • 8" INLET PIPE (SE) FROM MH 1442 INV. 478.75. BOTTOM OF WET WELL qt ELEV. 477.22' 1. THE EXISTING LIFT STATION SHALL REMAIN IN SERVICE DURING THE ENTIRETY OF THE PROJECT. THE CONTRACTOR SHALL PROVIDE ANY ANO All TEMPORARY BYPASS PUMPING WHILE THE UFT STATION IMPROVEMENTS ARE TAKING PLACE. DURING ANY BYPASS PUMPING, THE CONTRACTOR SHALL BE REQUIRED TO KEEP A SPARE BYPASS PUMP AVAILABLE. CONTRACTOR SHALL DEVELOP AND SUBMIT ANY BYPASS PLANS TO OWNER & ENGINEER, PRIOR TO IMPLEMENTATION, FOR REVIEW. 2. STATION DOWNTIME SHALL BE KEPT TO A MINIMUM. 3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT ALL AFFECTED UTILITIES PRIOR TO THE BEGINNING OF PUMP REPLACEMENT. 0 SECTION 1 ---- NOTTO SCALE 4. SEE ELECTRICAL PLANS FOR IMPROVEMENTS INCLUDED WITHIN THE SCOPE OF THIS PROJECT. 5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROTECT THE EXISTING LIFT STATION AND ALL EQUIPMENT DURING CONSTRUCTION. 6. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DISPOSE OF ALL DEMOLISHED MATERIALS. THE DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS 7. THE OWNER HAS RIGHTS TO ALL DEMOLISHED MATERIALS (PUMPS, VALVES, PIPING, ETC.) CONTRACTOR TO COORDINATE SALVAGED ITEMS WITH OWNER PRIOR TO DEMOLITION WORK. SALVAGED ITEMS SHALL BE DELIVERED BY THE CONTRACTOR TO A PLACE SPECIFIED BY THE OWNER (LOCATION TO BE WITHIN THE CITY OF WASHINGTON). SITE PLAN AND RENOVATION DETAILS • RE\r1SIONS BID SET C 2025 Midwestern Engineers, Inc P80.O2.WBoe>xt2fl9r5oadway Sui;:et Loogootee, Indiana 47553 DAT£ JULY 2025 DESIGN R.D.W. DRAWN J.A.J. Q.C. CHECK PROJECT NUMBER 2024042-04 3 3 OF 4 I FllE NUMBER I 45095 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2