0 z " z w " � w .; " ,_ w " < .:,-f "' w Q ' w � w � ' � z > ' 8 ;; vii 0 .. �o = :.:.. cu < � No "o � Q • rn lol �;; :i: 0" "'" :<:: � mw •" -w �� -� Qo "u "' 1.1' - I w � � 0 N_ � "J 5i <c GENERAL ELECTRICAL NOTES ALL WORK SHALL COMPLY WITH INDIANA ELECTRICAL CODE, CURRENT EDITION. PROVIDE ALUMINUM UNI-STRUT AND ACCESSORIES AS REQUIRED TO MOUNT ELECTRICAL EQUIPMENT. ALL HARDWARE SHALL BE STAINLESS STEEL. ALL BURIED CONDUIT SHALL BE SCHEDULE 80 PVC, ALUMINUM FOR EXPOSED UNLESS OTHERWISE NOTED. GROUT AROUND ALL PENETRATIONS INTO CONCRETE STRUCTURES. TYPICALLY USE LONG SWEEP ELBOWS. SEPARATE ALL POWER AND CONTROL INTO DEDICATED CONDUITS. ALL ENCLOSURES SHALL BE NEMA 4X STAINLESS STEEL UNLESS OTHERWISE NOTED. ALL ENCLOSURES SHALL HAVE A HASP AND STAPLE FOR PADLOCK. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONDUIT, WIRING. OTHER MATERIAL, AND INSTALLATION FOR A COMPLETE AND FUNCTIONAL SYSTEM. CONTRACTOR TO LOCATE ALL UNDERGROUND UTILITIES PRIOR TO EXCAVATION. SEED, STRAW OR STONE ALL SURFACES TO PRE-DISTURBED CONDITION. CONTRACTOR TO REMOVE UNUSED ELECTRICAL EQUIPMENT AS A RESULT OF THE PROJECT. OWNER RESERVES THE RIGHT TO ANY REMOVED EQUIPMENT. ANY UNWANTED EQUIPMENT, MATERIAL, CONDUCTORS, ETC. SHALL BE DISPOSED OF BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. ENSURE 5' MIN. BETWEEN WETWELL VENT AND JUNCTION BOX. LOCATE NEW JUNCTION BOX AT A MIN. OF 18" ABOVE TOP OF WELL. CONTRACTOR TO VERIFY CONDUIT SIZE BETWEEN JUNCTION BOX AND PUMPS IN WET WELL TO ACCEPT PUMP POWER CABLES (PER NEC). ALL UTILITY FEES WILL BE PAID BY OWNER IN FULL PRIOR TO CONSTRUCTION. CONTRACTOR TO CONTACT JASON FLOCK w/ HARRISON CO. REMC AT 812-738-4115 A MIN. OF THREE WEEKS PRIOR TO COORDINATE SWITCH OVER. NOTIFY OWNER OF ALL REQUIRED OUTAGES A MIN. OF 48 HOURS IN ADVANCE. POWER FOR TEMPORARY BYPASS PUMPING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL COORDINATE THE EXACT LOCATION OF ELECTRICAL EQUIPMENT WITH THE OWNER IN THE FIELD DURING CONSTRUCTION PRIOR TO INSTALLATION. CONTRACTOR SHALL PROVIDE CONDUIT AND WIRE AS NECESSARY TO ACQUIRE THE FOLLOWING DIGITAL INPUTS WIRED TO COMMON ALARM INTO THE BEACON, 120V INPUT, SITE POWER FAIL DRY CONTACT, WETWELL HIGH LEVEL PUMP #1 ALARM PUMP #1 SEAL LEAK PUMP #1 OVERTEMP PUMP #2 ALARM PUMP #2 SEAL LEAK PUMP #2 OVERTEMP I -- ----is-- ---- ' ... � \ : - . - - I � .. LENGTH OF STAND x 4' DEEP ALUMINUM ANGLE WELDED TO ALUMINUM BASE PLATE (4) Y," STAINLESS STEEL ALL-THREADS IN CONCRETE 4"x4"xl/4." ALUM. ANGLE Y," ALUM. BASE PLATE BASE DETAIL JUNCTION BOX STAINLESS STEEL CABLE ACCESS ALUMINUM 1 • CONTINUOUS PIANO HINGE NOT TO SCALE FRONT VIEW RIGHT SIDE LEFT SIDE VIEW VIEW i,...::::' :.....,i -n,;. FACE-MOUNT PADLOCKABLE HASP LOUVER PLATES STAINLESS STEEL NOTE, JUNCTION BOX DIMENSIONS SHOWN ARE FOR REFERENCE ONLY, CONTRACTOR TO SIZE FOR APPLICABLE PUMP APPLICATION. JUNCTION BOX DETAIL NOT TO SCALE .. .... .... ·-·- - s - - .- . SETTLERS TRACE 0 •----�•--1-- w ---w--- w 0 �L� - �J ATION ELECTRICAL SITE PLAN LEGEND ·//// EXISTING EQUIPMENT TO BE REMOVED AND/OR • REPLACED PER PROPOSED ONE LINE DIAGRAM. - - - - EXISTING CONDUIT, WIRING, AND EQUIPMENT PROPOSED CONDUIT, WIRING, AND EQUIPMENT I EXISTING 120/240V-3•,----f"" � 7 4W ELECTRIC SERVICE BY HARRISON co. L ,r)1"'1, J REMC TO REMAIN r-=: 1 - = � EXISTING ELECTRIC METER----.r;, #216320125 BY HARRISON CO. REMC TO REMAIN EXISTING WESTINGHOUSE-- - -/ DISCONNECT AND GROUNDING ELECTRODE SYSTEM TO BE REMOVED PUMP CONTROL PANEL, CONDUIT AND WIRE TO-<------./ BE REMOVED IN THEIR p ENTIRETY, GROUT WETWELL PENETRATIONS AS REQUIRED FOR WATER TIGHT FINISH L/ -c /_/--,,f--;'¼ �� PUMP #1 24DV-3• 22 FLA PUMP #2 24OV-30 22 FLA EXISTING ELECTRICAL ONE LINE DIAGRAM NOT TO SCALE CONTRACTOR TO PROVIDE AND INSTALL FOUR ,- CONDUITS BETWEEN JUNCTION BOX AND PUMP CONTROL PANEL EACH w/ CLASS I DIV. I SEAL OFFS, TYP. USE MYERS HUBS. -(1) 2" PUMP #1 POWER 1) f RIGID ALUMINUM CONDUIT -(1) 2'' PUMP #2 POWER -(1) 1" DIGITAL CONTROL 3"x3" ALUMINUM ANGLE -(1) 1" SPARE METER BASE AND METER I EXISTING 120/240V-3•,---, � 7 4W ELECTRIC SERVICE BY HARRISON co. REMC L � J � 1__: = £ 'c: EXISTING ELECTRIC METER-----r;t � #216320125 BY HARRISON � co. REMC TO REMAIN CD (i) (4) #3/0 THWN IN 2" CONDUIT 0 200A-3P SERVlCE ENTRANCE RATED CIRCUIT BREAKER DISCONNECT IN NEMA 4X S.S. ENCLOSURE BY SQ.D. OR ENGINEER APPROVED EQUAL 0 (1) #4 CU. GND. EXOTHERMICALLY WELDED TO (3) ¾" CU. CLAD GND. RODS ON 1D' TRIANGULAR SPACING 0 (4) #3/0 THWN, (1) #6 CU. CLAD GND. IN 2" CONDUIT ® PROPOSED PUMP CONTROL PANEL IN NEMA 4X S.S. ENCLOSURE, SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION 0 0 )-200A-3P ® (3) #1D THWN, (1) #10 CU. GND. IN 2" CONDUIT HANDLETIE 0 (j) FIELD LOCATE PROPOSED JUNCTION BOX w/ OWNER DURING CONSTRUCTION PRIOR TO INSTALLATION LIFT STATION PUMP CONTROL PANEL �_ , 100A-3P )-60A-3P )-60A-3P l NEMA l NEMA 1ODA APPLETON RECEPTACLE, POWERTITE w/ MOUNTING BOX, 4W, 4P, STYLE 1. REVERSE SERVICE, CAT. #ADJA1D44RS w/ HUB SIZE AND POLARIZATION AS REQUIRED CHOSEN BY CONTRACTOR 100A-3P SIZE 1 SIZE 1 CABLES PROVIDED BY--------1 PUMP MANUFACTURER, � ' � • ti ' - @11= INSTALLED BY CONTRACTOR 7.5HP 7.5HP � ll= PUMP #1 240V-3• 22 FLA PUMP #2 240V-3• 22 FLA PROPOSED ELECTRICAL ONE LINE DIAGRAM NOT TO SCALE LEO DUSK TO DAWN LIGH T ON WP SWITCH NEW ALUMINUM UNI-STRUT RACK IN PLACE DF WOODEN STAND ' LIFr - STATION -FIELD VERIFY NEW VENT, HOIST #216320125 BY HARRISON SOCKET AND JUNCTION BOX LOCATION PUMP � PROPOSED OMNI SITE BEACON UNIT PROPOSED GENERATOR RECEPTACLE, FIELD VERIFY OWNERS PLUG CONFIGURATION PRIOR TO ORDERING. CHECK ROTATION AT COMPLETION OF PROJECT. CO. REMC TO REMAIN ,_. CONTROL w/ OWNER DURING CONSTRUCTION SERVICE ENTRANCE RATEo-----"'" v PANEL PRIOR TO INSTALLATION 200A-3P CIRCUIT BREAKER DISCONNECT IN m "'" i:;' NEMA 4X S.S. ENCLOSURE (� 4"x4" ALUMINUM ANGLE NEMA 4X S.S. µ w w •• ANCHOR JUNCTION BOX, 1 � STAND TO CONCRETE LID, EXISTING UNDERGROUND CORE DRILL ENTRY TO FEED TO REMAIN, WETWELL SUPPORT AS REQUIRED • • � • � ,\I - ,_, . . . � . ;: ' • .J... � .. • ' •• J ! • . • • . . ' . • j • • • .; • � k E ="' " V ( \ .. , (2) 7.5 HP 240V-3• 22 FLA • � • • • -. { � MIN. 1 B" . . . • . ; ; • , .. . . ; . . • ' • FOUR (4) CONDUITS w/- . • LONG SWEEP ELBOWS ; BETWEEN PUMP CONTROL PANEL ANO JUNCTION BOX, SIZE AS INDICATED • \\ 9, • • • • • • • • ; \----,4-::._I---NEW FLOATS, TYP. OF 4 . - . j •' . �. • ;.• • , .. .. - • . . • ' • '· . . . , • • . . ; . . . • • X . . · .. . • • .1· .. � • . • ' • • -1. •• ' . •" • . • •f j • . . -GROUNDING ELECTRODE SYSTEM PER ONEUNE DIAGRAM -SEE CONCRETE BASE DETAIL THIS SHEET FOR MORE INFORMATION LIFT STATION ELECTRICAL RISER NOT TO SCALE REVISIONS 4/12/24 BID SET C 21)24 Midwestern Engineas. Inc. 802 w�st Broadwuy Street ?.O. Box 295 Loogootee. In,1iana 47553 DATI APRIL 2024 DESIGN A.F.B. DRAWN C.N.M. a.c. CHECK PROJECT NUMBER 2024049-00 5 5 OF 5 I FllE NUMBER Y 4 l\?Y I Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2