Midwestern Engineers, Inc. Plan Preview

" N 0 N 0 N ' I ':, ' ' � ' ' ' ·, • I ' .. � " " = , , ITEM EF-1 ITEM UH-1 I FIXTURE WC-1 UR-1 L-1 SH-1 HB-1 HYD-1 ' GENERAL CAPACITY DIMENSIONS ITEM AREA MANUFACTURER MODEL EER I I WEIGHT (MBH) L w H 6.7 (HEAT) AH-1 RESTROOM TIRANE TPKFYPD06LM1408 6.0 (COOL) 30.4. 9S 11.a· 24.5 13.8 CU-1 OUTSIDE tm:MSH36A142M 45.0 (HEAT) 41.3. 18" 52.3" TIRANE CMY-Y64-G-E 36.0 (COOL) 278 EXHAUST FAN SCHEDULE GENERAL FAN DATA ELECTRICAL LOCATION MANUFACTURER MODEL WEIGHT CFM S.P. RPM SONES VOLTS PHASE MCA MOCP (IN} I I I RESTROOM GREENHECK SP-B110ES 10 100 0.25 650 2.0 120 1 0.25 15 ELECTRIC UNIT HEATER SCHEDULE GENERAL RESISTANCE HEAT ELECTRICAL DIMENSIONS LOCATION MANUFACTURER MODEL WEIGHT SIZE OUTPUT VOLTS PHASE MCA MOCP L I w I H (KW) (MBH) STORAGE Q'l<RK QMKC2513W-TA2AW 36" 2-7/8" 6-3/4" 9 I 0.75 2.56 I 120 1 6.5 15 PLUMBING FIXTURE ROUGH-IN SCHEDULE & MOUNTING HEIGHTS ROUGH-IN SIZES DESCRIPTION I I MOUNTING HEIGHT cw HW TRAP WASTE VENT WATER CLOSET - FLUSH VALVE, AfJA 1• - - 4• 2· 17• TO SEAT URINAL - AfJA 3/4" - - 2· 1 1/2" 17" TO RIM LAVATORY - WALL HUNG, AfJA 1/2" 1/2" 1 1/4" 1 1/2" 1 1/2" 34" TO DECK SHOWER 1/2" 1/2" - I - - 72" HEAD, 24" FOOT SPRAY, 42" V&VE HOSE BIBB 3/4" - - - - 24" WALL HYDRANT 3/4" - - - - 18" ABOVE GRAOE PLUMBING MATERIAL SCHEDULE DOMESTIC WATER SANITARY WASTENENT SANITARY WASTENENT SYSTEM ABOVE GRADE ABOVE GRADE BELOW GRADE HARD COPPER TUBE HARD COPPER TlJBE PVC PVC MATERIAL TYPE 'L' TYPE 'L' SCHEDULE 40 SCHEDULE 40 ASTM 888, NSF 61 ASTM 888, NSF 61 ASTM D1784 ASTM 01784 SIZE 1/2" THRU 4" 1/2" THRU 4" 1-1/2" THRU 6" 2" THRU 6" FITTINGS WROUGHT COPPER COPPER/EPDM PVC OVN PVC DVN f,,SME 816.22 ASME B16.51 ASTM D2665 ASTM 02665 LfAD-FREE SOLDER PRESS-CONNECT SOLVENT CEMENT SOLVENT CEMENT JOINTS ASTM 832 IAPMO PS-117 ASTM 02564 ASTM 02564 COMPLY WITH GOA'S JOIN TUBE AND COMPLY Wffil ASTM COMPLY WITH ASTM INSTAUATION FITTINGS WITH TOOLS 02665 ANO D2855, 02321. SANITARY TEES "COPPER TUBE REQUIREMENTS HANDBOOK" RECOMMENDED BY NOT PERMITTED IN AND SHORT-SWEEP FITTING MFR. RETURN AIR PLENUMS FITTINGS NOT PERMITTED - COMPLY WITH MSS-SP-58 COMPLY WITH MSS-SP-58 1/2" THRU 3/4" C 5' SPACING, 3/8" ROD 1-1/2" THRU 2"@ 5' SPACING, 3/8" ROD 1• THRU 1-1/4• 0 6' SPACING, 3/8• ROD 3• 0 5' SPACING, 1/2" ROD HANGERS 1-1Jr THRU 2- 0 8' SPACING, 3/8• ROD 4" Cl 5' SPACING, 5/8" ROD NOT APPLICABLE 2-1Jr THRU 4" 0 1O' SPACING, 1/2� ROD 6" 0 5' SPACING, 7/8" ROD VERTICAL P!PE O 10' SPACING VERTICAL PIPE C 1O' SPACING COMPLY WITH ASTM E84 INSULATION 1" PREFORMED FIBERGLASS WITH PSJ NOT REQUIRED NOT APPLICABLE ASTM C552, TYPE n, CLASS 2 -- TEST WITH WATER AT 10' TES'TING TEST WITH WATER AT 50 PSI ABOVE WORKING TEST W\TH WATER AT 1O' HEAD FOR 2 HOURS. PRESSURE FOR 24 HOURS AIR TEST NOT PERMITTED. HEAD FOR 2 HOURS. AIR TEST NOT PERMITTED. FLUSH WITH POTABLE WATER. FlLL SYSTEM I REMOVE DIRT AND DEBR!S WITH WATER/CHLORINE SOLUTION AT 50 PPM REMOVE DIITT AND DEBRIS AS WORK AS WORK PROGRESSES. CLEANING FOR 24 HOURS. FLUSH WITH POTABLE WATER. PROGRESSES. PLUG OPEN ENOS EACH DAY PLUG OPEN ENDS EACH DAY SUBMIT WATER SAMPLES TO IDOH. REPEAT I WHEN WORK STOPS. WHEN WORK STOPS. UNTIL SATISFACTORY RESULTS ARE OBTAINED. SPLIT SYSTEM SCHEDULE INDOOR UNIT OUTDOOR UNIT ELECTRICAL PIPING NOISE HEAT HEAT COOL COOL CFM LIQUID/SUCTION EAT EAT EAT EAT CONTROLLER CFM NOISE REFRIGERANT SUPPORT VOLTS PHASE MCA MOCP (IN) (OBA) (DB) (WB) (DB) (WB) (OBA) TAC-Yf 53CRAU-J 191 (HIGH) 0.25/0.50 31 (HIGH) 70.0 70.0 80.0 67.0 SIMPLE MA CONTROU.ER - - - - CLEAR CO VER GUARD - � 240 1 36.0 40 ' I ' QSMS1202M - - - - - - - - 3885 I 49/53 R410A 12• HIGH STAND PLUMBING EQUIPMENT SCHEDULE ELECTRICAL DATA ITEM DESCRIPTION BASIS OF DESIGN I I CAPACITY INSTALLATION NOTES EQUAL MANUFACTURERS LOAD VOLTS PHASE l ELECTRIC WATER HEATER I I TERMINATE T&P RELIEF OVER FLOOR WH LOCHINVAR 4.5 KW 240 1 I 19 GPH RECOVERY AT 100'F RISE DRAIN, SET OUTLET TEMPERATlJRE A.O. SMITH, BRADFORD WHITE, LES-408-DAK 40 GALLONS STORAGE RHEEM, STATE --- ._hT 140'F THERMOSTATIC MIXING LAWLER 5.5 GPM AT 10 PSI MAX. J f 140"F HOT WATER, COLD WATER BRADLEY, LEONARD, POWERS, TM\/ - - - V&VE 61-15 PRESSURE DROP, � GPM MIN. !NLETS, ,If 120"F HOT WATER OUTLET SYMMONS TACO ARMSTRONG, BELL & GOSSETT, CP CIRCULATION PUMP 0.54 A 120 1 2.0 GPM AT 10 FEET HEAD FURNISH WITH AQUASTAT I 007E-SF4 GRUNDFOS AMTROL I ' BELl & GOSSETT, TACO, EXPANSION TANK + - I - 2.0 GALLONS TANK VOLUME f f SYSTEM CONNECTION ST-5 CALEFACTIO I I 7'I THERMOSTATIC ZONE VALVE THERMOMEGA TECH I N/A N/A CS-1/2-120-TW - - APPROVED EQUAL ' PLUMBING FIXTURE SPECIFICATIONS FIXTURE BASIS OF DESIGN DESCRIPTION EQUAL MANUFACTURERS WC-1 UR-1 L-1 SH-1 HB-1 HYD-1 F0-1 co WHA Af'F AG AR AfJ &T BAS BF BG BFP BOP BTU BTIUH CB Cl co COND CP csw ()/ cw OF DIA OS ON ow EC ET EWC EWH FD FS GPM GC GFWH GR HB HR HW HWR HYO ' FIXTURE: AMERICAN STANDARD 3451.001 FIXTURE: FLOOR MOUNT, BOTIOM OUTITT, WHITE VITREOUS CHINA, 1.28 GPF, ELONGATED BOWL FIXTURE: ZURN, KOHLER, SLOAN FLUSH VALVE: SLOAN SOUS 8111-1.28 I FLUSH VN....VE: EXPOSED BRASS BODY, SENSOR OPERATED, SOLAR POWERED, 1.28 GPF, 1• SPUD FLUSH VALVE: APPROVED EQUAL SEAT: BEMIS 1655SSCT SEAT: MOLDED SOLID PLASTIC, OPEN FRONT, ELONGATED, EXTRA HEAVY DUTY, SELF-SUSTAINING HINGE SEAT: CHURCH, OLSONITE FIXTURE: AMERICAN STANDARD 6590.001 FIXTURE: WALL MOUNT, BACK OUTLIT, WHITE VITREOUS CHINA, 0.5 GPF, WASHOUT FLUSH ACTION, CONCEALED CARRIER FlXTURE: ZURN, KOHLER, SLOAN FLUSH VALVE: SLOAN SOUS 8186-0.5 FLUSH VALVE: EXPOSED BRASS BODY, SENSOR OPERATED, SOLAR POWERED, 0.5 GPF, 3/4- SPUD FLUSH VALVE: APPROVED EQUAL FIXTURE: AMERICAN STANDARD 0355.012 FIXTURE: WALL MOUNT, WHITE VITREOUS CHINA, CONCEALED ARM CARRIER, THREE HOLES ON 2• CENTERS FIXTURE: ZURN, KOHLER, SLOAN FAUCET: SLOAN EFX-275-4-SOL-BOM-CP-1.5 FAUCET: DECK MOUNT, SOLID BRASS, CHROME PLATE, 1.5 GPM, SENSOR OPERATED, SOLAR POWERED, 4• TRIM PLATE FAUCET: APPROVED EQUAL FIXTURE: FRONT MOUNTED BUILT-IN SHOWER, STAINLESS STEEL WALL PANELS WITH VANDAL RESISTANT HARDWARE, FlXTURE: WILLOUGHBY INDUSTRIES (2) SINGLE TEMP PNEUMATIC MITTRING VALVES, VALVE MANIFOLD, 2.0 GPM, (2) CHROME PLATED ANGlE FIXTURE: APPROVED EQUAL WSIS-FA-L-PML1-MA2-PBH-2.0-LRSH-TESH-TMV SHOWER HEADS, INUNE THERMOSTATIC MIXING VALVE +- FlXTURE: WOODFORD MODEL 26 FlXTURE: BRASS BODY, CHROME PLATE, ASSE 1052, HOSE THREAD OUTLET, METAL WHEEL HANDLE I FIXTURE: J.R. SMITH, ZURN, JOSAM I -- - � FIXTURE: WOODFORD MODEL 67 FlXTURE: BRASS BODY, CHROME PLATE, SEPI\RATE DRAIN TUBE, ASSE 1052, HOSE THREAD OUTLET, WAl..1 CLAMP FlXTIJRE: J.R. SMITH, ZURN, JOSAM � I FIXTURE: J.R. SMITH 2041S-A FIXTURE: CAST IRON, SIDE SPIGOT OUTLET, INTEGRAi.. TRAP, CLEANOUT, ADJUSTABLE ROUND NICKEL BRONZE TOP FIXTURE: ZURN, JOSAM 1 FIXTURE: J.R. SMITH 4101S (CONCRETE) FIXTURE: CAST IRON, SPIGOT CUTI.ET, BRONZE PLUG WITH GASKET, ROUND SCORIATED NICKEL BRONZE COVER FIXTURE: ZURN, JOSAM FIXTURE: J.R. SMITH 5005 FIXTURE: J.R. SMITH 5010 FIXTURE: J.R. SMITH 5020 FlXTIJRE: J.R. SMITH 5030 ABBREVIATIONS ABOVE FINISHED FLOOR 1MB ABOVE GRAOE INV ACCESS PANEL L AREA DRAIN LT ALTERNATE MBH BUILDING AUTOMATION SYSTEM MC BELOW FLOOR MH BELOW GRADE MS BACKFLOW PREVENTER NPW BOTTOM OF P!PE ,ITT BRmSH THERMAL UNIT ORO BTlJ PER HOUR OSD CATCH BASIN PRV CAST IRON RD CLEANOUT RPZ CONDENSATE SAN CIRCULATION PUMP SE COLD SOFT WATER SF CONTROL VALVE SH COLD WATER SK DRINKING FOUNTAIN SP DIAMETER ss DOWNSPOUT ss OOWN ST DISHWf,,SHER no ELECTRICAL CONTRACTOR TM\/ EXPANSION TANK TOP ELECTRIC WATER COOLER 1YP ELECTRIC WATER HEATER UR FLOOR DRAIN V FLOOR SINK VB GALLONS PER MINUTE VCP GENERAL CONTRACTOR vs GAS FIRED WATER HEATER VTR Gf,,S REGULATOR WB HOSE B!BB WC HOSE REEL wco HOT WATER WHA HOT WATER RETURN ws WALL HYDRANT 7'I - FlXTIJRE: STAINLESS STEEL BEllOWS, FACTORY PRESSURIZED, POI-A, 3/4• CONNECTION, 1-11 FU RATING FIXTURE: STAINLESS STEEL BELLOWS, FACTORY PRESSURIZED. PDl-8, 1• CONNECTION, 12-32 FU RATING FlXTURE: STAINLESS STEEL BELLOWS, FACTORY PRESSURIZED, PDI-C, 1• CONNECTION, 33-60 FlJ RATING FlXTURE: STAINLESS STEEL BELLOWS, FACTORY PRESSURIZED, POI E, 1• CONNECTION, 61 113 FU RATING PLUMBING SYMBOLS AND ABBREVIATIONS PLUMBING SYMBOLOGY ICE MAKER BOX --M- SHUTOFf VALVE r ELBOW INVERT ELEVATION LAVATORY f-- ANGLE VALVE 1+1 TEE LAUNDRY TUB -lOI-- BALANCING VALVE cJ PIPE TURNING DOWN THOUSANDS OF BTIJ PER HOUR MECHANICAL CONTRACTOR f BALL VALVE - P1PE TIJRNJNG UP MANHOLE MOP SINK I� BUfilRFL Y VALVE ---<p-- TEE UP NON-POTABLE WATER NOT TO SCALE --i'-J- CHECK VALVE T TEE DOWN OVERFLOW ROOF DRAIN ---4- CONTROL VN....VE -a-- DROP AND RUN OPEN SITE DRAIN f PRESSURE REDUCING VALVE PLUG VALVE --I>- REDUCER ROOF DRAJN --0-- --ilf-- REDUCED PRESSURE BFP PRESSURE REDUCING VALl/f. UN!ON SANITARY DRAIN SOLENOID VALVE ',j STRAINER -- SEWAGE EJECTOR FlXTURE: ZURN, JOSAM SIOUX CHIEF I DRAWING SYMBOLOGY - -- - - - csw --14- - --14... A G D -- COLO WATER HOT WATER HOT WATER RETURN COLO SOFT WATER 140' HOT WATER 140" HOT WATER RETURN COMPRESSED AIR NATURAi.. Gf,,S DRAIN/RELIEF - - DEMOLmON SQUARE FOOT 'f- SAFETY RELIEF VALVE SUSPENDED CLEANOUT ------ - VENT SHOWER SINK -=- BACKFLOW PRE.VENTER • PIPE CAP II SANITARY (ABOVE GRADE} SUMP PUMP HOSE BIBB - - PIPE SLEEVE '7 SANITARY (BELOW GRAOE) SAFETY SHOWER q STAINLESS STEEL WALL HYDRANT PIPE ANCHOR STORM DRAIN 9 I STORM {ABOVE GRADE) PRESSURE GAUGE --=- FLEXIBLE CONNECTION TRENCH DRAIN / STORM (BELOW GRADE) THERMOSTATIC MIXING VALVE � THERMOMETER FLOW ARROW TOP OF PIPE Ill ACID (ABOVE GRAOE) lYPICAL ---0-- PUMP = PIPE SLOPE DIRECTION URINAL 0- ACID (BELOW GRAOE) -f"l- AUTOMATIC AIR VENT €) FLOOR DRAIN VENT 0 VACUUM BREAKER jcMI G>S METER ,a FLOOR SINK PLAN NOTE VITRIFlED CLAY PIPE VENT STACK @ WATER METER 0 CLEANOUT EB DET.AJL NUMBER VENT TI--IRU ROOF DET�L/SECTION CLOTHES WASHER BOX WATER CLOSET DRAWING SHEET WALL CLEANOUT WATER HAMMER ARRESTER WASTE STACK ZONE CONTROL VALVE GENERAL PLUMBING & HVAC NOTES 1. THESE NOTES APPLY TO All PLUMBING ANO HVAC DRAWINGS. ADDmONAL GENERAL NOTES SPECIFIC TO A PARTICULAR DRAWING ARE SHOWN ON THOSE SHEETS. 2. All PLUMBING SYSTEMS TO BE INSTALLED TO MEET THE REQUIREMENTS OF THE INDIANA PLUMBING CODE, 2014 (INTERNATIONAL PLUMBING CODE, 2006 WITH INDIANA AMENDME"1S). COMPLY WITH ADA ANO ACCESS\BIUTY LAWS AND REGULATIONS AND ALL OTHER AUTHORmES HAVING JURISDICTION. 3. ALL HVAC SYSTEMS TO BE INSTAllfD TO MEET THE REQUIREMENTS OF THE INDIANA MECHANICAL CODE, 2014 (INTERNATIONAL MECHANICAL CODE, 2012 WITH INDIANA AMENDMENTS). 4. WORK INCLUDES FURNISHING Ali LABOR, MATERIALS, APPLIANCES, EQUIPMENT, TOOLS, TRANSPORTATION, SUPERINTENDENCE, CLEAN-UP, ANO SERVICES REQUIRED TO CONSTRUCT ANO INSTALL A COMPLETE FULlY OPERATIVE PLUMBING ANO HVAC SYSTEM FOR THE PROJECT. 5. Ali NEW WORK IS DRAWN DARK. ALL ITEMS DRAWN LIGHT ARE EXISTING. EXISTING ITEMS SHALL REMAIN UNLESS SPECIFlCAU.Y NOTED OTHERWISE. 6. CONTRACTORS SHALL PROTECT Ali EXISTING OWNER FACIUTIES DURING CONSTRUC110N. ANY ITEM DAMAGED OR DISCONNECTED BY CONTRACTOR OPERATIONS SHALL BE FUllY RESTORED TO PREVIOUS OPERATING AND APPEARANCE CONDITION. PROVIDE PLATING AS REQUIRED TO PROTECT SURFACE OF EXISTING PARKING LOT INCLUDING UNDER WHEELS OF DUMPSTER, LIFTING DEVICES AND OTHER EQUIPMENT THAT COULD SINK INTO ASPHALT. 7. ALL UNDERLINED EQUIPMENT lS SCHEDULED, SEE SCHEDULE SHEETS. B. CONTRACTOR SHALL COORDINATE WORK WITH ALL OTHER TRADES AND STRUCTlJRAL CONOmONS PRIOR TO INSTAl.l.ATION. CONTACT ENGINEER WITH CONFIJCTS OR DISCREPANCIES. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR CORE OR1WNG Al'lD ClITTING HOLES THRU WALLS ANO FLOORS AS REQUIRED TO INSTALL NEW PIPING WHETHER SHOWN OR NOT. 10. UNLESS OTHERWISE NOTED, INTERIOR DRAINAGE PIPING SHALL BE INSTALLED AT J f PER FOOT SLOPE. 11. PIPE AND DUCTWORK ROUTINGS SHOWN ON DRAWINGS ARE DIAGRAMMATIC ANO ARE A SUGGESTED METHOD FOR DES!GN. CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL COORDINATION, LAYOUT, AND CODE COMPLIANCE. 12. SCAl.£S INDICATED ARE FOR ARCHITECTURAL REFERENCE ONLY. DO NOT SCALE DRAWINGS. rT IS NOT INTENDED THAT THE DRAWINGS SHOW EVERY PIPE, DUCT, FITTING, SUPPORTS, ETC., ANO fT IS UNDERSTOOD THAT THE DRAWINGS MUST BE FOLLOWED AS CLOSELY AS CIRCUMSTANCES Will PERMIT, THE PROPER INSTAl.l.ATION ACCORDING TO THE TRUE INTENT AND MEANING OF THE DRAWINGS, LOCAL CODES AND STANDARD PRACTICES SHAU BE PROVIDED. 13. ALL FLOOR MOUNTED EQUIPMENT SHALL BE MOUNTED ON A CONCRITT HOUSEKEEPING PAD. 14. CONTRACTOR SHALl. FJELD VERIFY EXISTING PIPE AND EQUIPMENT SIZES, LOCATIONS, ELEVATIONS, MATERIALS, ETC. BEFORE BIDOJNG OR BEGINNING WORK. 15. CONTRACTOR SHALL COORDINATE SHUT DOWN OF AfN MECHANICAL SYSTEM WITH THE OWNER, OCCUPANTS OF THE AFFECTED AREA, ANO AfN OTHER AUTHORfIY HAVING JURISDICTION. 16. REMOVE ALL PIPING, VALVES, EQUIPMENT, ETC. MADE OBSOLITT f,,S A RESULT OF NEW CONSTRUCTION. 17. THOROUGHLY REVIEW ALL DRAWINGS PRIOR TO ANY DEMOUTION WORK. ANY DEVICES REMOVED ACCIDENTALLY Will BE REPLACED AT NO ADDmONAL COST TO OWNER. 18. DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL, STATE, ANO FEDERAL REGULATIONS. 19. PIPING SUPPLIES TO FIXTURES ARE SAME SIZE AS INDICATED IN ROUGH-IN SCHEDULE UNLESS OTHERWISE NOTED ON DRAWINGS. 20. FURNISH AND INSTAl..1 ALL ITEMS NECESSARY TO MEET THE REQUIREMENTS OF THE UTILITY COMPANY WHETHER INDICATED 1N DRAWINGS AND SPECIFICATIONS OR NOT. VERIFY PIPING ROUTING AND RUNS, TAP LOCATIONS, ANO INVERT ELEVATIONS REQUIRED PRIOR TO COMMENCING WORK. 21. COORDINATE DELIVERY ANO STORAGE OF MATERIALS WITH THE OWNER. 22. FURNISH ALL CERTIFICATES OF APPROVALS BY THE BUILDING INSPECTOR ANO BOARD OF HEALTH. REVISIONS 23. MAINT.AJN A MINIMUM CLEARANCE OF THREE FEET IN FRONT OF ELECTRICAL PANELS ANO ONE FOOT EITHER SIDE WITH PIPE. 24. INCLUDE IN BIO, ALL LICENSE, PERMIT, INSPECTION ANO OTHER FEES REQUIRED TO COMPLETE WORK. 25. DUR!NG CONSTRUCTION PROCEDURES, THE ENTIRE WORK AREA SHALL BE CLEAN OF ALL DUST, DIRT AND OTHER DEBRIS BEFORE APPLICATION OF AfN NEW MATERIALS. 26. ALL PIPING ANO DUCTWORK SHALL BE CONCEALED ABOVE CEILINGS AND WITHIN WALLS UNLESS OTHERWISE NOTED. 27. ALL WALL THERMOSTATS SHALL BE APPROXIMATELY 4'-6• ABOVE FINISH FLOOR TO BOTIOM AND BE LINED UP HORIZONTALLY WITH LIGHT SWITCHES, UNLESS NOTED. THERMOSTATS IN PUBLIC AREAS SHALL HAVE CLEAR LOCKING COVERS. 8/8/24 BID SET C 2024 )..'\idwe,1em Engineers. Inc. S02 Wt<! Ur<);,dway Str�et P.O. Box 295 LoopJ<Jtcc. !n.Jlain;i 47553 DATE AUGUST 2024 DESIGN W.A.E i'.'.NAK. DRAWN C.N.M. Q.C. CHECK A.F.B. PROJECT NUMBER 2024056-00 1 0 10 OF 12 I F1LE NUMBER I 44272 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2