Midwestern Engineers, Inc. Plan Preview

I 0 0 ' N 0 0 C • w , [ ' � ., ;\ � " ' ' LIGHT FIXTURE SCHEDULE Type Manufacturer / Model A NEWSTAR LIGHTING - CATALOG No. VIC4N-L1-35-1C-RWC-UN-WH B HUBBELL OUTDOOR LIGHTING - CATALOG No. WGH2-LSCS Mounting Lamps SURFACE 25W LEO SURFACE 41.2W LED NOTE, CONTRACTOR SHALL PROVIDE ALL REQUIRED MATERIALS, BRACKETS, CABLES, PHOTOCELLS, ETC. FOR FULLY FUNCTIONAL SYSTEM. NOTL CONTRACTOR TO CONTACT TRAVIS BELDEN w/ ESL SPECTRUM AT (317) 800-8552 FOR LIGHT FIXTURE PRICING PRIOR TO BIO. GENERAL ELECTRICAL NOTES NO MORE THAN SIX CURRENT CARRYING CONDUCTORS (INCLUDING NEUTRAL CONDUCTORS) IN ANY ONE CONDUIT CARRYING 20-AMP LIGHTING OR RECEPTACLE LOADS WITHOUT DERATING IN ACCORDANCE w/ NEC ARTICLE 310. ALL OTHER CIRCUITS SHALL BE IN A DEDICATED CONDUIT. PROVIDE GROUND CONDUCTOR IN ALL CONDUITS. SIZE PER NATIONAL ELECTRIC CODE. ALL WIRING SHALL COMPLY w/ THE LATEST EDITION OF THE INDIANA ELECTRIC CODE AND COMPLY w/ COUNTY AND/OR LOCAL JURISDICTION HAVING AUTHORITY IN THAT AREA. ELECTRICAL CONTRACTOR SHALL COORDINATE w/ THE MECHANICAL CONTRACTOR THE EXACT LOCATION AND ROUGH-IN REQUIREMENTS FOR ALL MECHANICAL EQUIPMENT AND PIPING BEFORE ROUGH-IN. ELECTRICAL CONTRACTOR SHALL COORDINATE w/ ALL OTHER TRADES AND OWNER BEFORE WIRING IS TO BEGIN TO VERIFY ALL OTHER CONDITIONS SO THAT WIRING WILL NOT INTERFERE w/ THE OTHER TRADES. ALL ELECTRICAL SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE w/ THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE ENTIRE ELECTRICAL SYSTEM SHALL BE INSTALLED IN A NEAT ANO WORKMANLIKE MANNER. ALL MATERIALS USED IN THE WORK SHALL BE APPROVED BY THE UNDERWRITER'S LABORATORIES, INC., AND SHALL BEAR THEIR LABEL. THE CONTRACTOR SHALL, AT HIS/HER OWN EXPENSE, OBTAIN ALL PERMITS, INSPECTIONS, CERTIFICATES, ANO LICENSE REQUIRED BY LAW FOR THE EXECUTION OF WORK TO BE PERFORMED. THE ELECTRICAL CONTRACTOR, UNLESS OTHERWISE NOTED, SHALL FURNISH AND INSTALL ALL MATERIAL AND EQUIPMENT AS INDICATED ON THE DRAWINGS. ALL MATERIALS ANO EQUIPMENT SHALL BE NEW AND OF FIRST CLASS CONSTRUCTION, AND SHALL BE THE PRODUCT OF AN ESTABLISHED AND REPUTABLE MANUFACTURER, AND SHALL BE DESIGNED TO PERFORM THE SERVICE REQUIRED. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL HARDWARE, LAMPS, ACCESSORIES, ETC. AS REQUIRED FOR A COMPLETE ANO WORKING SYSTEM. MULTI-WIRE (SHARED NEUTRAL CIRCUITS) SHALL NOT BE USED. PROVIDE A NEUTRAL CONDUCTOR FOR EACH LINE-TO-NEUTRAL CIRCUIT. ALL POWER ANO CONTROL CIRCUIT WIRING USED SHALL BE '1HHN" OR ''rHWN" COPPER UNLESS OTHERWISE SPECIFIED OR REQUIRED BY CODE. PER NEC 310.10, ALL WIRING SHALL BE SIZED TO COORDINATE w/ TEMPERATURE RATINGS OF TERMINATIONS. LISTED WIRE SIZES ON PANELBOARO SCHEDULES ARE MINIMUM SIZES. SIZE WIRE TO MEET TEMPERATURE ANO VOLTAGE DROP REQUIREMENTS. PROVIDE A PULL ROPE IN ALL SPARE CONDUITS. PROVIDE ID TAG AT EACH END OF PULL ROPE IDENTIFYING LOCATION OF OPPOSITE END. ALL SAFETY SWITCHES SHALL BE "HEAVY DUTY" G� A-6,,,.,,WP - MAG LOCK w/ INTERIOR "REX" & EXTERIOR KEYPAD- (TYP. OF 4) LOW VOLTAGE .Ll� WIRING TO DOOR ,r CONTROL PANEL IN MECHANICAL ROOM UNISEX R.R.#1 "A" PANEL 400AMPERES MCBMAIN CONNECTION SI DRAGF/MECHANICAi ROOM LOCATION A 120/240VOLTS 1 PHASE SURFACE MOUN TING 1- ---SQ.D NQ PANEL, SERVICE .'iWIRE ')') KAIC S.EL ENTRANCE RATED NEMA 1 C!RCU!T ITEM FEED WIRE AMPS POLE NO. SIZE 1 HAND DRYER #1 12 20 1 3 HAND DRYER 113 12 20 1 5 INTERIOR LIGHTS & EXHAUST FANS 12 20 1 7 RESTROOM RECEPTACLES 12 20 1 9 WATER HEATER B 40 2 11 13 UNIT H�TER 12 20 1 15 CIRCULATION PUMP 12 20 1 17 SPARE 12 20 1 19 SPARE 12 20 1 21 SPARE 12 20 1 23 SPARE 12 20 1 25 SPARE 12 20 1 27 SPACE 29 SPACE 31 SPACE 33 SPACE 35 SPACE 37 SPACE 39 SPACE CU. BUS A B A B A B A B A B A B A B A B A B A B POLE AMPS WI RE SI ZE ITEM FEED CIRCUIT NO. 20 20 20 20 2 40 20 20 20 20 20 20 20 12 HAND DRYER 112 2 12 HAND DRYER /14 4 12 EX TERIOR RECEPTACLES 6 12 STORAGE/MECHANICAL RM. RECEPTS. 8 8 CONDENSING UNIT 10 � 12 12 EXTERIOR LJGHTS 14 12 MAG LOCK DOOR CONTROL PANEL 16 12 SPARE 18 12 SPARE 20 12 SPARE 22 12 SPARE 24 12 SPARE 26 SPACE 28 SPACE 30 SPACE 32 SPACE 34 SPACE 36 SPACE 38 SPACE 40 41 SPACE A SPACE 42 NOTE: INTERNAL SURGE PROTECTION DEVICE IS 80KA PER PHASE, 40KA PER MODE w/ SURGE COUNTER [:J ' ! EXTERIOR LIGHT FIXTURES ON DUSK TO DAWN CONTROL ' I �A" - -0 "A ' f 1 c'-+--------+------� 1 j' LOW VOLTAGE [ PROPOSED EXELERATOR HAND DRYER (TYP OF 4) MOTION SENSOR LIGHT SWITCHES (TYP. OF 4) - I I �LOW VOLTAGE ' 1 "A " 0- ) - ENCLOSURE, INTEGRAL SPD . . I I ;@ CONTROL PANEL IN l WIRING TO DOOR r L� - WIRING TO DOOR CONTROL PANEL IN �LOW VOLTAGE I ---�- WIRING TO DOOR � CONTROL PANEL IN I MECHANICAL ROOM A-1 - FAMILY -1,1 R.R.#1 A-2 - MECHANICAL ROOM A-3 FAMILY - R.R.#2 - . MECHANICAL ROOM A-4 -, UNISEX R.R.#2 ,--{) T I ""1<>1 --._ , •I . -,,,.-.JJ "I'I ... � I 1- GFl A-7� - - -· "A" - -i}>+-- 1 I AH-1 AH-1 () " A" ---+{ f.- - - I ( I I I , -¢- - - GFl �A-7 Al-1 I ' 1, ' I I GFI � ,A - 6 PROPOSED----1-�. , ----+�=<>- 0CCUPANCY PROPOSED AQUASTAT FOR CIRCULATION PUMP CONTROL I I I I ' - � � SENSOR. OMNI-DT-2DOO (TYP. OF 4) EF-1 /j ' -, C :L - " - - W.H. ',,.@ I A-9, 11 \ / - /,/ -....... - EF-1' "/ 1 ' •0) o ;/. I ' -'- '0 EF-1 - _..L::-:=::lE=====;:i,_- __J -1- � c=i= = �3E=.':il�'--__J " A � rlh f====r� =1Y c-/ A-15 GFlq:p A-8 A-16 / UH - 1 I A-13 d STORAGE/ MECHANICAL RO M -OH -- "A"_____ " � -H " o- NOTE, MAINTAIN NEC CLEARANCE IN FRONT OF PANEL A-5 - �PROPOSED 2 POLE I I LIGHTING CONTACTOR w/ 1 _"�I '" - �"'"1'�"' u·'*� PROPOSED 4DOA, SERVICl L;/� ENTRANCE RATED, NQ, ---=-- EF-1 = STUB UP SCH. 80 PVC CONDUITS EACH ENO FOR FUTURE USE A-8 ---�,; 12D/240V-10 PANEL "A" - iIB, ::1 °0 _L__l' =�;;��;:-�, ==E=:§3::=r!=:i:c:===·:--L� /1 ' I I" PROPOSED MAG LOCK DOOR CONTROL PANEL, SEE DOOR SCHEDULE FOR MORE INFORMATION (3) #600 MCM THWN . },J 4" SCH. 80 PVC CONDUIT / PROPOSED 400A CL320 METER BASE- I 11 A-1D�PROPOSED 6DA-2P NON FUSED DISCONNECT IN NEMA 3R ENCLOSURE [ CU-1 I PROPOSED QUAZITE PULL BOX w/ (4) 2" SPARES ANO (4) 1" SPARES, CONTRACTOR TO SIZE PER NEC. CONTRACTOR TO PROVIDE ANO INSTALL 4" SCH. _L 40 PVC BELOW GRADE, w/ 36 " LONG SWEEP ELBOWS AND PULL ROPE. CABLING, RISER ANO --------� TERMINATIONS BY CENTERPOINT ENERGY. " _L-______. ' "' TO EXISTING POWER POLE, SEE SITE PLAN FOR 1 CONTINUATION. MIN. 36" COVER w/ WARNING TAPE AT 18". L- _ #1/0 BARE CU. GND. IN JI" CONDUIT EXOTHERMICALLY WELDED TO ), (3) Jl"•x10' CU. CLAD GNO. ROOS ON 10' TRIANGULAR SPACING PROPOSED ELECTRICAL PLAN SCALE, ),'' = 1'-0" I REVISIONS ' ' BID SET Cl 2024 Mirlwc.,1�n1 Engin,·ers. Jnc. 802 West Br<1:}(l\\ay Sm,el P.O. B,,x 2').5 L<:>w•oo1,-.;. Indiana . J7.5.5J DATE AUGUST 2024 DESIGN W.A.E.i:'N.A.K DRAWN C.N.M. a.c. CHECK A.F.B. PROJECT NUMBER 2024056-00 1 1 11 DF 12 FllE NUMBER 44271 I Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2