Midwestern Engineers, Inc. Plan Preview

TAJ � C 0 0 a 0 0 C w' N 0 0 ... w N oc 0 o' "' C 0 I N 00 C 0 w a :I': w w , w C 0, o, :; 'i' .0 N9 ow NW 'O "• =N •o 2w •• Ow -a Qc "' ,o �u �z 0 ;;1 -< �� LN �£ , . s C 2 3 4 IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT ALL R.R. FIXTURES ARE INSTALLED PER THE CURRENT EDITION OF THE ADA STANDARDS FOR ACCESSIBLE DESIGN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY INSTALLATION KITS, MOUNTING SCREWS, & ANCHORING DEVICES NOT LISTED FOR THE SPECIFIED EQUIPMENT, AS WELL AS PROVIDING ANY ADDITIONAL REINFORCEMENT REQUIRED TO INSTALL PER THE MFGR's RECOMMENDATIONS. RESTROOM ELEVATIONS MAY NOT REPRESENT ACTUAL FIXTURES USED BUT ARE SHOWN TO REPRESENT REQUIREMENTS PER ADA STANDARDS. BASIS-OF-DESIGN PRODUCTS, SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS AS INDICATED IN R.R. FIXTURE SCHEDULE FOR TOILET ACCESSORIES OR COMPARABLE PRODUCTS. ITEM No. DESCRIPTION MFGR MODEL No SIZE TAI SOAP DISPENSER BRADLEY CORP. 6562 40 oz TA2 FIXED TILT MIRROR BRADLEY CORP. 740-018360 18" X 36" TA3 ELECTRIC HAND DRYER XLERATOR XL-SB 12"W x 12"H x TA4 TOILET TISSUE DISPENSER BRADLEY CORP. 5402 (2)-5"¢ ROLLS 6"0 TA5 BABY CHANGING STATION KOALA KARE KB300-00 36"W x 22"H x 4"D / 50LB GBI 1)<;''¢ HEAVY DUTY GRAB BAR BRADLEY CORP. 812-001-036 1Yz"¢ X 36"L GB2 1),"¢ HEAVY DUTY GRAB BAR BRADLEY CORP. 812-001-054 1),"¢ x 54"L GB3 1),"¢ HEAVY DUTY GRAB BAR BRADLEY CORP. 812-001-018 1/f'¢ X 18"L NOTES, I) SEE SHEET "12" FOR PARTITION SPECIFICATIONS. •1•1 .J�.t • j1lffi - OPENING DOOR / FRAME HEAD JAMB SILL HARDWARE SET KEY # REMARKS No WINDOW DTL DTL DTL ROOM NAME FLOOR BASE WALLS CEILING I01 DI FI/H.M. HI JI SI I Kl SEE DOOR HARDWARE NOTE I MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH 102 DI Fl/H.M. HI JI SI 1 Kl SEE DOOR HARDWARE NOTE I 103 01 Fl /H.M. HI JI SI 1 Kl SEE DOOR HARDWARE NOTE I 104 DI Fl/H.M. HI JI S1 1 K1 SEE DOOR HARDWARE NOTE 1 105 01 Fl /H.M. HI JI SI 1 K1 SEE DOOR HARDWARE NOTE 2 DOOR SCH. NOTES, I) SEE SHEET "6" FOR DOOR DETAILS. HARDWARE SET No. 1 MFGR / MODEL No. 3 DOOR HINGE ANSI A156.1 US32D/630 IVES/ 5BB-1-HW-4.5x4.5-NRP UNISEX #1 X X X ENTRY MORTISE LEVER LOCK ANSI A156.2 US32D/630 SCHLAGE / LV9056-XL13-439 06A UNISEX #2 X X X DOOR BOTTOM SHOE w/ RAIN DRIP ANSI A156.22 MILL ALUMINUM PEMKO / 21OAV FAMILY #1 X X X OFFSET ADA THRESHOLD ANSI A156.21 MILL ALUMINUM PEMKO / 158A FAMILY #2 X X X PERIMETER SELF-ADHESIVE SEAL ANSI A156.22 BLACK PEMKO / S88BL STOR/MECH X X X DOOR CLOSER ANSI A156.4 689 LCN / 4030 SERIES DOOR HARDWARE NOTES, 1. CONTRACTOR SHALL PROVIDE ALL MATERIALS AND LABOR NECESSARY FOR A COMPLETE & FUNCTIONAL SYSTEM, INCLUDING BUT NOT LIMITED TO, LOW VOLTAGE WIRING, PVC CONDUIT, & DOOR HARDWARE AS FOLLOWS:. DOORS 101-104 SHALL EACH BE EQUIPPED w/ A 12/24 voe. 500mA/250mA MAGNETIC LOCK BY "SECO-LARM" MODEL#: E-941SA-1200 COMPLETE w/ "POK" OUTDOOR KEYPAD, & (REX) INDOOR BUTTON & MOTION SENSOR. INTEGRATE ALL EQUIPMENT VIA "POK" DOOR CONTROLLER LOCATED IN STORAGE ROOM. MAG LOCK, REX, & KEYPAD TO BE RELAYED THROUGH 24 HR TIMER. CONTRACTOR SHALL CONTACT ASTRO SECURITY INC. OF JASPER IN (PH, 812.389.1111) FOR PREFERRED SETUP. SUBMIT ALL EQUIPMENT TO OWNER FOR VERIFICATION BEFORE ORDERING. 2 NO MAGNETIC LOCK, USE STOREROOM MORTISE LOCK BY SCHLAGE LV9480 06A w/ IVES LATCH PROTECTOR MODEL#, LG1-US320 FINISH SPECIFICATIONS: 1. EPOXY FLOOR COATING, HIGH SOLIDS EPOXY COATING CONCRETE FLOORING SYSTEM SHALL BE AS MANUFACTURED BY SHERWIN WILLIAMS COMPANY. PROVIDE A 6"x6" MOCK-UP TO OWNER FOR APPROVAL. APPLY MOCKUPS TO VERIFY SELECTIONS MADE UNDER SAMPLE SUBMITTALS AND TO DEMONSTRATE AESTHETIC EFFECTS AND SET QUALITY STANDARDS FOR MATERIALS AND EXECUTION. APPLY FULL THICKNESS MOCKUPS ON 16 SQ FT AREA SELECTED BY OWNER. MOCKUP SHALL DEMONSTRATE DESIRED SLIP-RESISTANCE FOR REVIEW AND APPROVAL BY OWNER'S REPRESENTATIVE IN WRITING. INSTALL ALL PRODUCTS AS RECOMMENDED BY MANUFACTURER. HIGH SOLIDS EPOXY COATING FLOORING SYSTEM SHALL INCLUDE THE FOLLOWING, X X X X X X X X X X X X X X X X X X X X GENERAL FINISH NOTES: 1. SUBMIT COLOR AND TEXTURE SAMPLES OF ALL FINISHES ANO PRODUCTS FOR APPROVAL BY OWNER. X X X X X 2. PREPARE ALL SURFACES AND APPLY ALL PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 3. PAINTING CONTRACTOR SHALL CAULK ALL DISSIMILAR SURFACES PRIOR TO FINISHING WALLS WITH A PAINT ACCEPTING CAULK. COLOR SHALL BE WHITE U.N.O. 30'-o" [0/0 CMU] 4. ALL DOORS & FRAMES TO BE PAINTED IN FIELD FOLLOWING INSTALLATION. ' I <D ::) :,; 0 0 ' 0 ' ro <D n I "' ...... / � B "' 6 g" 7·-,r 7'-1j" - [8}-- TREATED 6x6 SYP#2 [gJ I I POST (TYP. OF 5) I I I I I I I 12" I I @ A @) I I LI' J ,-<.a . TA3 TAI - TA3 � £ = TAI ' ' �� ' FAMILY ' R.R.#1 LAV....� ---=- I TA2 '. l§ UNISEX - f-- . R.R.#1 , B A) 8-----1 �F.O. TA5 .· C ,.;.;;; 8" 1 5'-10" 18" 6'-3" I ' . I - f-- �F.O. I GB1 ,;:::: ,. I ' I UR.(� 0 N B 0 .:::. GB2 GB3 TA4 • v --- ---- --- - - - -- ---- -C- � -- �-- - � - e= ' - - � 2'-8" � / I , I GB1 STORAGE/ MECH. I ' ROOM 0 I I I "' I �'� 0 GB2 � I 6'-4" I TYP. ' ! I ' , I , , � �/A\ N �� FLOOR PLAN SCALE, 1/2" - 1'-0" i ' [gJ �C.O. � 18" - -- � � I � h TAI f : : � " . � ' ro I - GB1 (pw2 ' /, ,, ------- ' , ' . • <D �F.O. ' N I ..,. 3'-4" EA. EXTR. DOOR rf. � @ �c.o. 7'-lj" (@ 1J FAMILY R.R.#2 �F.D. 6'-3" @} �)?� ' 6'-4" 1 GB2 - - [gJ - L ,-. 18" - - . - 6 ' · 7'-1j" GB , ., ·U L TA3 � TAI - ' @� LAV I \ � f-- UNISEX R.R.#2 f---@J 5'-10" ' f-- - �F.D. 1---. i .J I� � �UR. -- -------------- ' - l 2'-8" GB1 0 I "' g" [gJ I fs"l • � I C ' -� ' i, �!37 ' I • ' 1, .. ,, ' . , ' , ,, ENER§ X.{<;Qc5 E[COMPLIA PER 2010 INDIANA CONSERVATION ENERGY CODE BASED ON _ _J NCE o. 1st COAT, ARMORSEAL 1000 HS, REDUCED TO 10% (2.0 MIL OFT/CT) b. 2nd COAT, ARMORSEAL REXTHANE I (3.0 MIL OFT/CT) c. SLIP-RESISTANCE: ARMORSEAL HI-WEAR ADDITIVE INTEGRATED w/2nd COAT @ 3 LB/GAL. d. TOPCOAT, ARMORSEAL REXTHANE I (3.0 MIL DFT/CT) e. COLOR, SELECTED BY OWNER FROM MANUFACTURER'S STANDARD COLORS. 2. RESILIENT WALL BASE, RESILIENT BASE SHALL BE MANUFACTURED BY SHAW CONTRACT. TRADITIONAL TOE COVE 4" HIGH, I /8" THICK, THERMOPLASTIC VINYL, COLOR SELECTED BY OWNER. ' GB11--11=> ' m " 56" MIN. ' ..,. I C INTERIOR R.R. ELEVATION SCALL 1/2" - 1'-0" TAI 1·-10" 1'-1 " 18" MIN. I .30" MIN CLEAR. I FLOOR AREA ' � GFI TA5 4'- " 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY MOISTURE TESTING FOR ALL FLOOR SLABS SCHEDULED TO RECEIVE EPOXY COATING. CONTRACTOR TO PROVIDE MOISTURE MITIGATION AS REQUIRED BY MANUFACTURES WRITTEN RECOMMENDATIONS BEFORE INSTALLING SCHEDULED MATERIAL. 6. SURFACES TO RECEIVE FINISHES SHALL BE THOROUGHLY CURED ANO DRY, AND FREE OF DIRT, GREASE, AND OIL. ALL CRACKS, HOLES ANO VOIDS IN MASONRY AND CONCRETE SURFACES SHALL BE FILLED & GROUND SMOOTH. 7. PRIME CONCRETE AND CMU WALLS ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS. 8. CONCRETE FLOORS NOT RECEIVING EPOXY COATING SHALL BE CURED & SEALED. B CLEAR 1 AREA UNDER SINK I II 48" MIN. '-1 " V'l."- " I /1 ' / .,\ '/ / J '.11" 6V " ; TAI INTERIOR R.R. ELEVATION SCALE, I /2" - 1'-0" 6" GB3r-_,.., - I ' � " M N. CLEAR FLOOR AREA TA4 z :, ' ASHRAE 90.1-2007 TABLE 5.5-4 WHERE BUILDINGS ARE LOCATED IN CLIMATE ZONE 4A ICATEO BELOW, SHALL MEET THE MINIMUM "R" VALUES OR "U" VALUES AS IND ROOF - R-38 WALLS ABOVE GRADE - R-13 WALLS BELOW GRADE - NR FLOORS "UNHEATED" - NR SWINGING DOORS - U-0.70 A INTERIOR R.R. ELEVATION SCALE, 1/2" - 1'-0" FLOOR PLAN REVISIONS BID SET (Cl 21J!4 ,\frhw:<1e111 Engineers. lnc. 8(1! West Broadwa) Street P.O. [l(>X 2<15 Loo,'.Oolrc. lndian;i 47553 DATE AUGUST 2024 DESIGN T.M.K. DRAWN S.L.H. Q.C. CHECK C.W.R. PROJECT NUMBER 2024056-00 4 4 OF 12 I FILE NUMBER I 44278 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2