Midwestern Engineers, Inc. Plan Preview
• UTILITIES GENERAL NOTES SHEET INDEX - TOPOGRAPHY SHOWN ON PLAN SHEETS IS INTENDED TO SHOW THE GENERAL LOCATION OF FENCES, SHEET NO DESIGNATION Electric: Gas: 1 CULVERTS, DRIVES, EXISTING UTILITIES, POINTS OF CONNECTION, ETC HOWEVER; THE EXACT LOCATION -- 1 COVER Centerpoint Energy {South Electric) Community Natural Gas Company, Inc. AND QUANTITIES SHALL BE VERIFIED AT THE TIME OF CONSTRUCTION 1800 W. 26th Street 933 W 3rd Street THE HORIZONTAL LOCATION DATA IS BASED UPON THE INDIANA STATE PLANE COORDINATE SYSTEM 2 INDEX AND GENERAL NOTES Muncie, IN 47302 Mt. Carmel, IL 62863 2 (WEST ZONE) REFERENCED TO THE 1983 NORTH AMERICAN DATUM (NAO 83) ELEVATIONS ARE BASED ON PH: 765-287-2119 Contact: Dean Kieffer 3 TYPICAL SECTIONS AND OVERALL MAP pubIicproject@centerpolntenergy.com PH· 618-263-3328 THE 1988 NORTH AMERICAN VERTICAL DATUM (NAVO 88). LOCATION CONTROL ROUTE SURVEY PLATS 4 dean@communitynaturalgas.com 3 THE CONTRACTOR SHALL CALL INDIANA UNDERGROUND SERVICES AT 811 PRIOR TO ANY CONSTRUCTION Southern Indiana Power TWO FULL WORKING DAYS BEFORE CONSTRUCTION IS TO BEGIN. 5 MAINTENANCE OF TRAFFIC OVERALL P.O. Box 219 Water I Sewer: THE LOCATION OF EXISTING UTILITIES ETC SHOWN ON THESE PLANS ARE NOT THE EXACT LOCATIONS 6 ALIGNMENT GEOMETRY Tell City, IN 47586 Town of Santa Claus BUT ONLY A GENERAL LOCATION ALTHOUGH THESE PLANS HAVE ATIEMPTED TO SHOW ALL EXISTING Contact Todd Hammond P.O. Box 92 UTILITIES, THE CONTRACTOR SHALL NOT ASSUME ALL EXISTING UTILITIES HAVE BEEN SHOWN. 7 PLAN AND PROFILE - LINE PR-1, E C.R. 1450 N / CLUB HOUSE ROAD PH: 812-547-2316 90 North Holiday Blvd. 4 THEREFORE IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO SEE THAT ALL EXISTING UTILITIES 8 PLAN AND PROFILE - LINE PR-2, OLD S.R. 245 thammond@southernindianapower.com Santa Claus, IN 47579 WITHIN CONSTRUCTION AREAS ARE CLEARLY MARKED IN THE FIELD PRIOR TO ANY CONSTRUCTION IN PH: 812-544-3329 THE AREA 9 PAVEMENT MARKING & SIGNAGE PLAN Communications: Contact: Russell Luthy Perry-Spencer Rural Telephone russ.Iuthy@townofsantaclaus.com THE CONTRACTOR SHALL BE REQUIRED TO IMPLEMENT DUST CONTROL MEASURES (SURFACE WETIING) 10 TYPICAL DETAILS 11877 East State Road 62 5 AS NECESSARY TO MINIMIZE FUGITIVE DUST EMISSIONS. ALL AREAS DISTURBED BY CONSTRUCTION 11 CROSS SECTIONS - LINE PR-1, C.R. 1450 N / CLUB HOUSE ROAD P.O.Box 126 SHALL BE SEEDED OR SODDED, UNLESS OTHERWISE SHOWN St. Meinrad, IN 47577 THE CONTRACTOR SHALL NOTIFY, IN WRITING, THE ENGINEER OF ANY CHANGES, OMISSIONS, OR 12 CROSS SECTIONS - LINE PR-2, OLD S.R. 245 Contact: Jim Ferguson 6 ERRORS FOUND ON THESE PLANS. PH: 812-357-2123 ALL CONSTRUCTION METHODS & MATERIALS MUST CONFORM TO CURRENT STANDARDS AND jferguson@pscfiber.net 7 SPECIFICATIONS OF THE FEDERAL, STATE, COUNTY, CITY/TOWN, OR LOCAL REQUIREMENTS, WHICHEVER HAS JURISDICTION FINAL GRADES AT THE PROJECT BOUNDARY SHALL MATCH EXISTING ELEVATIONS UNLESS OTHERWISE REVISIONS 8 SHOWN. SHEET NO DATE REVISED I 9 WHEN PERFORMING GRADING OPERATIONS DURING PERIODS OF WET WEATHER, PROVIDE ADEQUATE DEWATERING DRAINAGE AND GROUND WATER MANAGEMENT TO CONTROL MOISTURE OF SOILS AFTER STRIPPING TOPSOIL, THE SUBGRADE SHOULD BE PROOF-ROLLED WITH AN ADEQUATELY LOADED ra. a r,l11l1a811�1112,...111, VEHICLE SUCH AS A FULLY LOADED TANDEM-AXLE DUMP TRUCK TO DETERMINE LOCATIONS OF ANY 10 POCKETS OF UNSUITABLE MATERIAL AREAS EXCESSIVELY DEFLECTING SHOULD BE DELINEATED. RECOMMENDATIONS FOR DRYING, AMENDING, AND/OR REMOVAL OF ANY UNSUITABLE MATERIAL WITHIN THE PROPOSED PAVED AREAS WILL BE DETERMINED AT THE TIME OF CONSTRUCTION BY THE CONTRACTOR'S GEOTECHNICAL TESTING REPRESENTATIVE. IT IS THE CONTRACTOR AND OWNERS RESPONSIBILITY TO PREPARE AND FILE FOR A CONSTRUCTION 11 STORMWATER GENERAL PERMIT (CSGP) TO IDEM IF SOIL DISTURBANCE IS GREATER THAN ONE(1) ACRE. CSGP MUST BE OBTAINED PRIOR TO SOIL DISTURBANCE, IF REQ'D 12 CONTRACTOR/OWNER SHALL OBTAIN A COUNTY HIGHWAY PERMIT FOR ALL WORK WITHIN SPENCER LOCAL AGENCIES COUNTY, IN RIGHT OF WAY. 13 ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE SEEDED OR SODDED UNLESS OTHERWISE SHOWN. INDIANA DEPARTMENT OF TRANSPORTATION SPENCER COUNTY HIGHWAY DEPARTMENT PROVIDE POSITIVE DRAINAGE WITHOUT PONDING, IN ALL AREAS, AFTER INSTALLATION, CONTRACTOR TO Vincennes District Dale Kenney, Highway Superintendent 14 TEST FOR, AND CORRECT, IF ANY, "BIRD BATH" CONDITIONS. 3650 U.S. Highway 41 920 E 800 N Vincennes, IN 47519 Chrisney, IN 47611 PH: 812-882-8330 PH: 812-362-8331 swincommunications@indot.in.gov AUDITOR District Permit Manager Melissa Bunner Sara Polmanter 200 Main Street, Courthouse Rm 6 PH: 812-381-4566 Rockport, IN 47635 spolmanter@indot.in.gov PH; 812-649-6004 en rJ'.J 0 I- ;:) <( z < ow � <( 0:: :!!: u z W W <( en > < i5 ::, 0 z E-< 0 0:: > J: a. w z .... Ill � � z � < :::, � ::, z 0 rJ'.J .J 0 � u (J - t:.. a:: - I- 0 w It) (J u st w z z w N en D- 0 0:: � "' .J w 0 I- 0 z - E-< SPENCER COUNTY COMMISSIONERS James Seiler - District 1 2467 N Orchard Road Rockport, IN 47635 PH: 812-686-3102 Heather Gries - District 2 REVlSIONS 4970 E CR 2100 N Dale, IN 47523 PH: 812-630-5113 Thomas Brown - District 3 6378 E CR 700 N Grandview, IN 47615 PH: 812-686-6251 LEGEND WATER ELECTRICAL STORM SEWER t EXISTING 3-WAY FIRE HYDRANT AND VALVE E3 ELECTRICAL PEDESTAL qjD llID STORM STRUCTURES l EXISTING 2-WAY FIRE HYDRANT AND VALVE '" ELECTRICAL METER 12"VCP >-----< CULVERT TYPE AND SIZE t EXISTING FLUSH HYDRANT AND VALVE .¢-� LIGHT POLE 8 STORM MANHOLE yf YARD HYDRANT - UTILITY POLE WITH GUY 1/10/2025 ; EXISTING BLOW OFF AND VALVE BURIED ELECTRIC MISCELLANEOUS EARTHWORK QUANTITIES g PRESSURE REDUCING VALVE UIE OVERHEAD ELECTRIC "' SIGN CUT (cy) FILL (cy) NET (cy) [!J EXISTING LEAK DETECTION DEVICE OHE SATELLITE DISH • BID SET 592.64 452.99 139.64 @ WATER METER RIGHT OF WAY MARKER E3 SH SPRINKLER HEAD TELECOMMUNICATIONS MAIL BOX NOTE: 9 EXISTING GATE VALVE ...._ TELEPHONE PEDESTAL EARTHWORK QUANTITIES ARE 0 POST EXISTING BUTIERFLY VALVE -Fo� FIBER OPTIC WARNING/ LOCATE POST UNADJUSTED. CONTRACTOR TO ® El MANHOLE COORDINATE WITH OWNER FOR 0 EXISTING CHECK VALVE I"] TELEVISION PEDESTAL REDUCER • DISPOSAL OF EXCESS MATERIAL. C 1025 Midwestern Engineers. Inc. 802 We.st Bro:adway S1rcc1 P.O. Box 295 Loogootee. Indianu 47553 DATE � EXISTING CURB STOP BURIED COMMUNICATION LINE CAP COMM EXISTING WATER MAIN AND SIZE @ TREE w \_4" GAS WOOD FENCE I JANUARY 2025 DESIGN C.W.R. f_ B.D.H. SANITARY SEWER 4r GAS WARNING/ LOCATE POST WIRE FENCE DRAWN X ....,,._ FORCE MAIN WARNING/ LOCATE POST 3 EXISTING GAS VALVE ELECTRIC FENCE � EXISTING AIR RELIEF VALVE 'ijl GAS METER E CHAIN LINK FENCE ', @@) LIFT STATION AND VALVE PIT GAS MAIN AND SERVICE LINE Cl GAS [oo] __S) CLEAN OUT HOUSE I HOUSE TRAILER 9 EXISTING SANITARY VALVE SURVEY I H.T. I M.M.C. Q,C, CHECK PROJECT NUMBER 2024062-00 8 SANITARY MANHOLE • SURVEY POINT/ BENCH MARK RIGHT OF WAY RJW @) SANITARY GRINDER PUMP & SURVEY MONUMENT PROPERTY LINE ' SANITARY MAIN/ FORCE MAIN ,PL V HIGH WATER MARK SAN F/M - < ' 2 2 OF 12 ' INDEX AND GENERAL NOTES I ALE NUMBER I 44559 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2