� 0 � 0 0 0 ,, 0 <> �w <w ;,: oa 11 -· ! oo :;:;� N • Q ON N t- -0 Q � re «t w <t g � ' •" rj -W ., = ow i.l £� � NO ,u - 0 zZ l,l 8a � �· a� CN �-" . <• 30 15 0 30 LEGEND ----EX PROPERTY LINES --PROP. SITE BOUNDARY -PROP. RIGHT OF WAY - -PROP. BUILDING SETBACK lllil!ll!IPROP STREET t·c·-",1PROP. CONCRETE c::::::::::JPROP. BUILDING SITE LAYOUT PLAN NOTES 1. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE fESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECT THAT RESULTS IN A CONFLICT WITH THE PROPOSED DEVELOPMENT SHALL BE THE RESPONSIBILITY OF THE pEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED SHALL BE RELOCATED WITH IN ONE FOOT f)F THE PROPOSED RIGHT OF WAY LINE. 2. DEPTHS OF ALL EXISTING ONSITE UTILITIES SHALL BE VERIFIED BY THE 1 CONTRACTOR PRIOR TO CONSTRUCTION TO CONFIRM THERE ARE NO CONFLICTS WITH OTHER UTILITIES, STORM SEWERS, OR STREETS. ANY CONFLICT FOUND AFTER THE BEGINNING F CONSTRUCTION ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR 3. ALL PAVING WITHIN THE EXISTING AND PROPOSED TOWN RIGHT OF WAY SHALL CONFORM TO THE REQUIREMENTS OF THE TOWN. THE CONTRACTOR SHALL CONTACT THE TOWN TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE TOWNS CONSTRUCTION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK, AND TO REVIEW THE AUTHORJTY OF THE TOWN.AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT OF WAY. 4. pAMAGE TO EXISTING RIGHT OF WAY SHALL BE RESTORED/REPAIRED �0 THE SATISFACTION OF THE TOWN AT THE COMPLETION OF THE PROJECT THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT OF WAY WITHIN THE TOWN PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT OF WAY. / KEY MAP NT PR-A Number Radius Length Line/Chord Direction Pl PC PT Chord Length I L1 404.82 N89° 57' 50.00"W 0+00.00 Cl 42.50 67.18 N44° 40' 40.S0"W 4+47,75 4+04.82 4+72.01 60.40' L2 470.03 NO' 36' 29.00"E 4+72.01 C2 50.00 39.92 N22° 16' 00.S0"W 9+63.14 9+42.04 9+81.97 38,87' 0 � w "' 0 0 0 z b0 N � b 0 N � b0 N � I I I I I I I I N 89° 51' 30" E 218.59' ,----------------------------------, . . I I �l��il:ii?i:fJ?l!f�f-: r. LOT NO. 20 0.260 ACRES :�· / !� ' "' J m· ,. ,o \N t;i \ co o I 0"' II II ---' o: I f:-:/••t';'•;r·'-a;'j_•,:,: � I .:_1;{,;::ffk.;t..{·-;�\ '.. ., ___________________________________________________ ., 155.25' ---- r··----------------------------------------------------- LOT NO. 19 0 297 ACRES :- - ----- - -- ---------------------------------------------, - ! lifttH}\!:fJ�f?J ! ,� I LOT NO 18 0.306 ACRES b 0 ,1/': .;/:� .•,.�.•,; .. ' ,.,,, .,.. f-''"';; , _;:;,ts,,:.�?-�-�_,.,; .: . ,y/.i: ·1 L_____________________________________________________________, ��.J ,'-:,,:r:�1.--::::,..:.: ;�. �-.; :,' •;: 185 34' I ---- ----------------------------------- 184. 99' LOT NO. 17 0 306 ACRES LOT NO. 16 0 305 ACRES b0 N � w > -0::: <( o • 0 8: • • 0::: w • <( zIO ...J 0::: 0 N ---' ,9 1,9, 0 <D in N :,; 0 0 (f) ';';;'. h-c-----.........11.--..L--.....1.U...- MA TCHLI NE STA. 6+90 CONT'D ON SHEET 7 SITE LAYOUT PLAN • u 0 1--( REVISIONS 4/25/25 7 .a u BID SET 0 2025 Miciwcslem Engineers, Inc. 802 Wes1 Broadway Slrccl P.O. Box 295 Loogoo!ee. lndi�na 47553 DATE APRIL 2025 DESIGN CWRi'.EKPi'.BDH DRAWN DRKi'.MKW Q.C. CHECK PROJECT NUMBER 2024072-02 8 8 OF 45 I FILE NUMBER I 44747 Do Not Use Plan Previews for Take Off
RkJQdWJsaXNoZXIy NjAyODM2