PROPOSED WATER MAIN TO BE EXTENDED TO MARIAH HILL IN PHASE II (BY OTHERS) TO MARIAH HILL t ' • - • • • • • �I w 111 0 0 z ' " '- � • I N POINT OF CONNECTION No. 2 I �· >· lZ 0 0 CD < 0' 2" ,t U1 ' 0:: • POINT OF CONNECTION No. 1 I r • • 300 OVERALL PROJECT MAP LEGEND 00 12" t ' ♦ ,,,-112"1_ --®-- _,_ _ij_ -"1- • • ·,,,--71PROPOSED WATER MAIN FROM HOLIDAY VILLAGE PHASE I (SEE SHEETS 4-11 FOR DETAILS) 't'ELJ,JG DRIVE (C.R. 1750 N) Existing Water Main a11d Size Bxi.1·ting G.ue Valve Existing Flush Hydram Existing Fire Hydram Existing Wilter Mai11 to be Retired in Place Existing Water Merer Proposed !Vi1terReinlon;ements Proposed Cure \lalve Proposed Fire Hydrant Proposed Blow-Off Valve Proposed W.1ter Meter Ph.ue II Fmure WaterM11in (By Others) Town OfSanta Claus Coqxm1rion Limits .. ITO PLRWSD I MASTER METER PJT • NOEt UNITED METI-iOBtST. �Uaet, PLAN SHEET LEGEND: WATER ' t EXISTING 3-WAY FIRE HYDRANT AND VALVE EXISTING 2-WAY FIRE HYDRANT AND VALVE EXISTING FLUSH HYDRANT AND VALVE vf YARD HYDRANT ; & EXISTING BLOW OFF AND VALVE PRESSURE REDUCING VALVE qp EXISTING LEAK DETECTION DEVICE " WATER METER SH SPRINKLER HEAD e EXISTING GATE VALVE @ EXISTING BUTTERFLY VALVE " EXISTING CHECK VALVE "' EXISTING CURB STOP EXISTING WATER MAIN AND SIZE SANITARY SEWER --.- FORCE MAIN WARNING/ LOCATE POST � EXISTING AIR RELIEF VALVE @8 LIFT STATION AND VALVE PIT ---2 CLEAN OUT e EXISTING SANITARY VALVE 8 SANITARY MANHOLE @ SANITARY GRINDER PUeiM" SANITARY MAIN/ FORCE MAIN --SAN-- ELECTRICAL 8 ELECTRICAL PEDESTAL 10 ELECTRICAL METER -¢- lili LIGHT POLE ,,__. UTILITY POLE WITH GUY BURIED ELECTRIC ---E--- OVERHEAD ELECTRIC ----OHE---- PROPOSED 0 �-F ? ij" ~Y ·� --- PROPOSED WATER MAIN AND SIZE PROPOSED 3-WAY FIRE HYDRANT AND VALVE PROPOSED FLUSH HYDRANT AND VALVE PROPOSED BLOW-OFF HYDRANT PROPOSED WATER METER PROPOSED GATE VALVE PROPOSED BUTTERFLY VALVE PROPOSED CHECK VALVE PERMANENT WATER MAIN EASEMENT LIMITS EASEMENT LIMITS PROPOSED GRADING L -� ~ � "' ,P TELECOMMUNICATIONS --m-- TELEPHONE PEDESTAL -•0- FIBER OPTIC WARNING/ LOCATE POST 1!'1 TELEVISION PEDESTAL BURIED TELEPHONE -----T - - GAS -"<,'- GAS WARNING/ LOCATE POST li EXISTING GAS VALVE ;;, GAS METER GAS MAIN AND SERVICE LINE -----G-- - - - SURVEY SURVEY POINT/ BENCH MARK SURVEY MONUMENT HIGH WATER MARK STORM SEWER ®' illll STORM STRUCTURES >-''�"'-< CULVERT TYPE AND SIZE 8 STORM MANHOLE MISCELLANEOUS ® SIGN ' SATELLITE DISH El RIGHT OF WAY MARKER □ 0 I§ • -a I H.T. [jJ MAIL BOX POST MANHOLE REDUCER CAP TREE WOOD FENCE _, __ ,_ WIRE FENCE -,- -,- ELECTRIC FENCE ,--- CHAIN LINK FENCE -- oc-- oc-- HOUSE HOUSE TRAILER EASEMENT NUMBER 100 50 0 100 HEVRON ROAD BLOW UP OVERALL PROJECT MAP REVISIONS 8/1 /25 BID SET C 2025 Midwestern Engineers. Inc. 802 West Broadway Street P.O. Boi 295 Loogootee, Indiana 47553 DATE AUG. 2025 DESIGN C.W.R. DRAWN J.A.J. a.c. CHECK E.K.P PROJECT NUMBER 2024080-00 3 3 Df 13 I Fll£ NUMBER 45151 I Do Not Use Plan Previews for Take Off
RkJQdWJsaXNoZXIy NjAyODM2