Midwestern Engineers, Inc. Plan Preview

P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street 20 Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern BID SET Author: DPATTERSON, Plot Date: 4/2/2025 7:54 AM Path: Z:\CAD_INCOMPLETE\2024094-00_AKRON_PUBLIC WATER SYSTEM IMPROVEMENTS\025_PRODUCTIONDWG\DIVISION II\03 EAST_WEST WELLHOUSEIMPS.DWG WASTEWATER TREATMENT PLANT FACILITY PHOSPHORUS REMOVAL IMPROVEMENTS FOR THE CITY OF PLYMOUTH, MARSHALL COUNTY, INDIANA GENERAL NOTES : 1. CONTRACTOR TO REMOVE BUILDING ROOF AND REMOVE EXISTING WELL PUMP. 2. CONTRACTOR TO CLEAN AND REDEVELOP EXISTING WELL. 3. CONTRACTOR TO REINSTALL WELL PUMP AND REPLACE ROOF STRUCTURE. 4. NEW AIR RELEASE VALVE DRAIN LINE TO BE CONNECTED TO EXISTING DRAIN LINE. 5. RECONNECT ALL TUBES AND PIPING ASSOCIATED WITH PUMP OPERATION. 6. THE PROPOSED PIPE AND FITTING LAYOUT SHALL MATCH THE EXISTING LAYOUT. USE OF 6" SPOOL PIECES SHALL BE USED TO SPACE OUT THE REMOVAL OF THE EXISTING FLOW METERS. LEGEND EXISTING ITEM TO BE REMOVED WELLHOUSE I PIPING DEMOLITION DETAIL SEE GENERAL NOTE 2 SEE GENERAL NOTE 1 FILTER TANK EQUIPMENT KEY NUMBER PIPING SCHEDULE 1 Existing Pump Motor to be Pulled 2 Existing Discharge Head to be Pulled 3 Existing Pressure Gauge and Tubing to be Replaced as needed 4 Existing 6" x 2" DI ARV Tap to be Removed 5 Existing 11 2" x 1 2" Threaded Sample Tap to be Removed 6 Existing 11 2" Isolation Valve to be Removed 7 Existing ARV to be Removed 8 Existing 1" ARV DI Drain w/ Backflow Prevention Valve to be Removed 9 Existing 6" Flow Meter to be Removed 10 Existing 6" Check Valve to be Removed 11 Existing 6" Gate Valve to be Removed 12 Existing 6" DI Spool Piece to be Removed 13 Existing 6" DI Tee w/ Blind Flange to be Removed 14 Existing Pipe Stanchion to be Removed 15 Existing 6" DI Discharge Floor Pipe to Remain in Use. 16 Proposed 6" x 4" DI Tee w/ Threaded 11 2" Tap for New ARV Connection 17 Proposed 2" x 1 2" Sample Tap w/ Isolation Valve 18 Proposed 2" Isolation Valve and Threaded Pipe to New ARV 19 Proposed 2" ARV w/ 1" Drain Line and New Backflow Prevention Device 20 Proposed 6" DI Pipe 21 Proposed 6" Flowmeter 22 Proposed Check Valve 23 Proposed 6" Gate Valve 24 Proposed 6" DI 90° Bend 25 Provide Adjustable Pipe Support Stanchion as Needed. 26 Proposed ARV Drain line to Connect to Existing w/ Threaded Companion Flange 1 2 3 3 4 8 SEE GENERAL NOTE 1 1 2 3 3 4 SEE GENERAL NOTE 2 5 6 9 7 8 14 10 11 12 13 15 7 9 10 11 13 14 15 3 3 SEE GENERAL NOTE 3 19 17 16 23 22 21 20 18 24 25 SEE GENERAL NOTE 3 15 15 3 16 17 18 19 19 SEE GENERAL NOTE 4 SEE GENERAL NOTE 4 23 24 21 22 20 25 SEE GENERAL NOTE 5 EXISTING CONCRETE BASE (EXISTING WALL) (EXISTING WALL) (EXISTING WALL) (EXISTING WALL) EXISTING CONCRETE BASE EXISTING CONCRETE BASE SEE GENERAL NOTE 3 (EXISTING WALL) (EXISTING WALL) (EXISTING WALL) (EXISTING WALL) (EXISTING WALL) (EXISTING WALL) (EXISTING WALL) WELLHOUSE I PIPING IMPROVEMENTS - PLAN VIEW 3 3 19 16 20 23 22 21 24 26 1 3 1 3 PIPING IMPROVEMENTS SECTION VIEW 1 WELLHOUSE I I PIPING DEMOLITION DETAIL 3 (EXISTING WALL) 26 SEE GENERAL NOTE 5 SEE GENERAL NOTE 3 SEE GENERAL NOTE 3 SEE GENERAL NOTE 3 SEE GENERAL NOTE 3 WELLHOUSE I I PIPING IMPROVEMENTS - PLAN VIEW PIPING IMPROVEMENTS SECTION VIEW 2 2 3 2 3 ALUMINUM CONDUIT ALUMINUM CONDUIT 24 23 22 21 16 20 19 (EXISTING WALL) EXISTING CONCRETE BASE EXISTING CONCRETE BASE ALUMINUM CONDUIT EXISTING CONCRETE BASE 1 14 RAW WATER PRODUCTION WELL I AND WELL II IMPROVEMENTS 25 3 STATE OF No. PE60920059 MARK M. SULLIVAN PROFESSIONAL ENGINEER REGISTERED INDIANA

RkJQdWJsaXNoZXIy NjAyODM2