Midwestern Engineers, Inc. Plan Preview

P.ATOKA RIVER ' / 12" 12'' ii , • . . '1" ¥",'-, ' • � ... ' ���'!-:��� f I - '===�,, '" FEOX IRSCTEI NMG A1I0N" 1/ 10" F™ � ,., EEXFFI SLTUIENNGT1 2F"OWRCWETPMAIN " ._ ' FEOX IRSCTEI NMGA1I2N" PROJECT LOCATION MAP PA ANTDOSKEAWLEARK ED IRSET GR II OC TN A( PL LWR WA TSEDR) WASTEWATER TREATMENT PLANT 3098 N. STATE ROAD 545 DUBOIS, IN 47527 -- EEQXIUSATLINIZGATION TANK l"';j' c-.- .. PROPOSED I EXISTl�,G .,. ADMINISTRATION A [ D MC OI NNl STTRROALT/J @ N EB XU TI LEDNI NS GI O N r I BUILDING EX!STTRINEA�TMENKTAGE PLANT No. 1 E X I STTRI NE AGTPMAEC�KTA G E PLANT No. 2 --■f � E U X LT IS R T A IN .V G IOLET DISINFECJION 1---· '\_EXISTING EL IFFFTLSUTEANTTI O N EX t G DRY EDS � ESXLIUS DT IGNEG D E W&APTUEMRPI N G BUILDING PROJECT OVERALL MAP f PROJECT LOCATION • SCA!..£: 1" • 1000'- 10·-- r FEOX IRSCTEI NMGA1I0N" GENERAL NOTES: 1. TOPOGRAPHY SHOWN ON PLAN SHEETS IS INTENDED TO SHOW THE GENERAL LOCATION OF FENCES, CULVERTS, DRIVES, EXISTING UTILITIES, POINTS OF CONNECTION, ETC. HOWEVER; THE EXACT LOCATION AND QUANTITIES SHALL BE VERIFIED AT THE TIME OF CONSTRUCTION. 2. THE HORIZONTAL LOCATION DATA IS BASED UPON THE INDIANA STATE PLANE COORDINATE SYSTEM (WEST ZONE) REFERENCED TO THE 1983 NORTH AMERICA DATUM (NAD83) ELEVATIONS ARE BASED UPON THE 1988 NORTH AMERICAN VERTICAL DATUM (NAVO 88) 3. THE CONTRACTOR SHALL CALL INDIANA UNDERGROUND SERVICES AT (800) 382-5544 PRIOR TO ANY CONSTRUCTION TWO FULL WORKING DAYS BEFORE CONSTRUCTION IS TO BEGIN. 4. THE LOCATION OF EXISTING UTILITIES, ETC. SHOWN ON THESE PLANS ARE NOT THE EXACT LOCATIONS BUT ONLY A GENERAL LOCATION. ALTHOUGH THESE PLANS HAVE ATTEMPTED TO SHOW ALL EXISTING UTILITIES, THE CONTRACTOR SHALL NOT ASSUME ALL EXISTING UTILITIES HAVE BEEN SHOWN. THEREFORE IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO SEE THAT ALL EXISTING UTILITIES WITHIN CONSTRUCTION AREAS ARE CLEARLY MARKED IN THE FIELD PRIOR TO ANY CONSTRUCTION IN THE AREA. 5. DOWN TIME COORDINATION MUST BE MADE w/ THE SEWER UTILITY PRIOR TO TEMPORARILY SHUTTING DOWN/ CONNECTING TO EXISTING EQUIPMENT AND FACILITIES. COORDINATE w/ JOSH WALKER, WASTEWATER SUPERINTENDENT, AT (812) 678-5171, A MINIMUM OF FIVE (5) WORKING DAYS PRIOR TO TEMPORARILY SHUTTING DOWN ANY EQUIPMENT OR FACILITIES. 6. PROPERTY LINES, WHERE SHOWN, ARE BASED ON COUNTY PLAT RECORDS. THE SAID PROPERTY LINES ON THESE SHEETS DO NOT REPRESENT THE PROPERTY SURVEYS, BUT ARE ONLY APPROXIMATE LOCATIONS FOR REFERENCE PURPOSES ONLY. 7. IF ANY ARCHAEOLOGICAL ARTIFACTS OR HUMAN REMAINS ARE UNCOVERED DURING CONSTRUCTION, THE CONTRACTOR SHALL STOP ALL EXCAVATION WORK AND CONTACT THE INDIANA DEPARTMENT OF NATURAL RESOURCES, DIVISION OF HISTORIC PRESERVATION AND ARCHEOLOGY AT (317) 232-1646. NO ADDITIONAL EXCAVATION WORK SHALL BE DONE WITHOUT RECEIVING THEIR APPROVAL. 8. THE CONTRACTOR SHALL BE REQUIRED TO IMPLEMENT DUST CONTROL MEASURE (SURFACE WETTING) AS NECESSARY TO MINIMIZE FUGITIVE DUST EMISSIONS. 9. IF CAVERNS OR SPRINGS ARE ENCOUNTERED DURING EXCAVATION, WORK SHALL STOP IMMEDIATELY AND THE INDIANA DEPARTMENT OF NATURAL RESOURCES OR THE U.S. FISH & WILDLIFE OFFICE SHALL BE CONTACTED CONCERNING PROPER MITIGATION MEASURES. UTILITIES ELECTRIC: TELECOMS: WATER: SEWER: DUBOIS REC 1400 ENERGY DRIVE JASPER, IN. 47547 (812) 482 - 5454 ATTN: GREG DILGER FRONTIER COMMUNICATIONS 505 NEWTON STREET JASPER, IN. 47547 PATOKA LAKE REGIONAL WATER & SEWER DISTRICT 2647 N. SR 545 PATOKA LAKE REGIONAL WATER & SEWER DISTRICT 3098 N. S.R. 545 (812) 634 - 0335 DUBOIS, IN 47527 DUBOIS, IN. 47527 ATTN: SCOTT SHIELDS (812) 678 - 5781 (812) 678 - 5171 ATTN: DANIEL HALL ATTN: JOSH WALKER EMAIL: DANIEL@PLRWS.NET EMAIL: JOSHW@PLRWS.NET LEGEND: SURVEY SAN IT ARY SEWER TELECOMUNICATIONS � SURVEY POINT/ BENCH MARK & SURVEY MONUMENT ..,.__ FORCE MAIN WARNING/ LOCATE POST ---m-.- TELEPHONE PEDESTAL � EXISTING AIR RELIEF VALVE ~rn~ FIBER OPTIC WARNING/ LOCATE POST 'v HIGH WATER MARK MUNICIPAL BOUNDARY ---- WATER t EXISTING 3-WAY FIRE HYDRANT AND VALVE l EXISTING 2-WAY FIRE HYDRANT AND VALVE t EXISTING FLUSH HYDRANT AND VALVE Y◊H YARD HYDRANT ; EXISTING BLOW OFF AND VALVE !; PRESSURE REDUCING VALVE c:i EXISTING LEAK DETECTION DEVICE " WATER METER s• SPRINKLER HEAD " EXISTING GATE VALVE ® EXISTING BUTTERFLY VALVE 0 EXISTING CHECK VALVE "' EXISTING CURB STOP EXISTING WATER MAIN AND SIZE --W---W---W�\_,, SHEET INDEX 1 COVER SHEET 2 INFORMATION SHEET 3 SITE PLAN @0 LIFT STATION AND VALVE PIT _JJ CLEAN OUT " EXISTING SANITARY VALVE 8 SANITARY MANHOLE i§ SANITARY GRINDER PUMP SANITARY MAIN/ FORCE MAIN ELECTRICAL "1 ELECTRICAL PEDESTAL '" ELECTRICAL METER <?- lili LIGHT POLE - UTILITY POLE WITH GUY BURIED ELECTRIC OVERHEAD ELECTRIC 4 PROPOSED ADMIN. BUILDING ADDITION - FLOOR PLAN 5 PROPOSED ADMIN. BUILDING ADDITION - ELEVATIONS 6 PROPOSED ADMIN. BUILDING ADDITION - SECTIONS AND DETAILS 7 PROPOSED ADMIN. BUILDING ADDITION - ARCHITECTURAL SPECIFICATIONS 8 PROPOSED ADMIN. BUILDING ADDITION - FIRE AND LIFE SAFETY PLAN "" TELEVISION PEDESTAL BURIED TELEPHONE --T---T-- GAS � GAS WARNING/ LOCATE POST ii EXISTING GAS VALVE 'iY GAS METER GAS MAIN AND SERVICE LINE --CAS�-0'5--0'5 -- \_, .. STORM SEWER ® rnJ STORM STRUCTURES :,.'!:>'�-< CULVERT TYPE AND SIZE 8 STORM MANHOLE 9 PROPOSED ADMIN. BUILDING ADDITION - GENERAL STRUCTURAL SPECIFICATION AND NOTES 10 PROPOSED ADMIN. BUILDING ADDITION - STRUCTURAL LOADING REQUIREMENTS 11 PROPOSED ADMIN. BUILDING ADDITION - TYPICAL STRUCTURAL DETAILS 12 PROPOSED ADMIN. BUILDING ADDITION - TYPICAL STRUCTURAL MASONRY DETAILS 13 PROPOSED ADMIN. BUILDING ADDITION - TYPICAL STRUCTURAL LUMBER DETAILS 14 PROPOSED ADMIN. BUILDING ADDITION - STRUCTURAL FOUNDATION PLAN 15 PROPOSED ADMIN. BUILDING ADDITION - STRUCTURAL ROOF FRAMING PLAN 16 PROPOSED ADMIN. BUILDING ADDITION - STRUCTURAL BUILDING SECTIONS 17 PROPOSED ADMIN. BUILDING ADDITION - STRUCTURAL FOUNDATION DETAILS 18 PROPOSED ADMIN. BUILDING ADDITION - STRUCTURAL ROOF DETAILS 19 PROPOSED ADMIN. BUILDING ADDITION - HVAC PLAN 20 PROPOSED ADMIN. BUILDING ADDITION - ELECTRICAL PLAN Know what's below . Call before you dig. MISCELLANEOUS " SIGN o SATELLITE DISH El RIGHT OF WAY MARKER a MAIL BOX o POST @ MANHOLE • REDUCER CAP TREE WOOD FENCE WIRE FENCE ELECTRIC FENCE CHAIN LINK FENCE [ooJ HOUSE H.r. I HOUSE TRAILER INFORMATION SHEET REVISIONS Blq SET C 2025 �b1�:::;ltt:;;�::· P.O. Box 2951 Loogoo1ee, l�iana 47553 ' ' OAlE JULY �025 DESIGN I T.M.K. DRAWN C.N.M. Q.C. CHECK E.K.P. PROJECT NUMBER 2025005-01 i 2 OF 20 I Fllf NUMBER 45047 I Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2