Midwestern Engineers, Inc. Plan Preview
0 � Q Q t = u � !al :£ 0 0 0 0 0 z' �· C z 0 ,w < "' ow • "' i" 5 " ;, So ,N� �,< -c ' ......,;I)� O<j� I" ow .q; it � o::� <" o Q W t) i m 5! :,; u N_ 5N £5 , < <C DUBOIS COUNTY COMMISSIONERS CHAD BLESSINGER NICK HOSTETTER SERICE STENFTENAGEL PH. (8 l 2)-481- 7045 ONE COURT HOUSE SQUARE JASPER. fN 47546 PRESIDENT MEMBER MEMBER DUBOIS COUNTY HIGHWAY DEPARTMENT BRENT WENDHOLT. ENGfNEER EMAIL: BAWENDHOLT@DUBOJSCOUNTYlN.ORG STEVEN BERG, HIGHWAY SUPERVISOR EMAIL: SLBERG@DUBOISCOUNTYIN.ORG PH. (812)-482-5505 I066 S. STATE ROAD 162 JASPER, IN 47546 INDIANA DEPARTMENT OF TRANSPORTATION VINCENNNES DISTRICT 3650 SOUTH U.S. 41 VINCENNES, IN 4759 l PI-I (8 I2) -463-6848 DISTRlCT PERMIT MANAGER RANDY CARIE PH.(812)-895-7368 EMAIL: RCARJE@INDOT.lN.GOV DlSTRJCT PERMIT INSPECTOR JOYCE NEWLIN PH.(8I2)-203-201I EMAIL: JNEWLIN@INDOT.JN.GOV FAX. (812)-895-7479 EMAIL: SWlNCOMMUNICATIONS@JNDOT.IN.GOV SHEET INDEX • l. • 2. • 3. • 4 -16. • 17. • 18. • 19. • 20. • 21. • 22. • 23. • 24. • 25. • 26. • 27. • 28. • 29. • 30. COVER SHEET PLAN SHEET INFORMATION PROJECT LOCATION/ OVERALL MAP PROPOSED FORCE MAIN PLAN AND PROFILE SHEETS EXISTING LIFT STATION No. I FORCE MAIN RETIREMENT PLAN SHEET EXISTING LIFT STATION No. I DEMOLITION SITE PLAN EXISTING LIFT STATION No. I DEMOLITION DETAJLS EXJSTING LIFT STATION No. 35E MODIFfCATION SfTE PLAN EXISTING LIFT STATION No. 35E MODIFICATION PLAN AND DETAfLS PROPOSED LIFT STATION No. IA SITE PLAN PROPOSED LIFT STATION No. lA PLANS AND DETAILS PROPOSED LIFT STATION No. IA ELEVATED PLATFORM DETA[LS PROPOSED LIFT STATfON No. I A SITE ELECTRICAL PLAN AND ELECTRfCAL DETAILS PROPOSED LIFT STATION No. IA ELECTRICAL PLAN EQUALfZATION TANK AND VALVE VAULT DEMOLITfON AND GRADING PLAN EQUALIZATION TANK AND VALVE VAULT MODIFICATION PLAN AND DETAILS TYPfCAL SANITARY DETAILS LIFT STATION No. I & IA PROPERTY UTILITIES ELECTRIC: TELEPHONE: DUBOIS RURAL ELECTRJC. INC. 1400 ENERGY DR, JASPER, lN 47547 PH: J -8 I2-485-5455 PERRY SPENCER RURAL TELEPHONE COOP. INC. II 877 E. S.R. 62 ST. MEINRAD, IN 47577 PH: 1-812-357-2123 ATTN: JIM FERGUSON (JPERGUSON@PSCFIBER.NET ) PAOLI SUBDISTRICT 1222 N. GREENBRIAR DR. PAOLI, IN 47454 PH. (812)-203-2033 WATER: DUBOIS WATER UTILITIES, INC. 5470 E. WATERWORKS ST. DUBOIS, IN 47527 PH: I-812-678-5161 ATTN: ISAAC HEEKE (ISAAC@DUBOISWATER.COM ) PATOKA LAKE REGfONALWATER & SEWER DISTRICT 2647 N. S.R. 545 DUBOIS, IN 47527 PH: I-8I2-678-8322 ATTN: STEVE DODD (STEVE@PLR \VS.NET) FRONTIER COMMUNICATIONS PH: 1-855-552-9691 SEWAGE: PATOKA LAKE REGIONAL WATER & SEWER DISTRICT 2647 N. S.R. 545 GAS: ANR P[PELINE CO. I46 S CELESTINE RD. S. CELESTINE. fN 47521 PH: I-8I2-634-I99I Know what's below. Call before you dig. DUBOIS, IN 47527 PH: 1-8 I 2-678-5I71 ATTN: JOSI-I WALKER (JOSHW@PLRWS.NET ) GENERAL NOTES: 1. TOPOGRAPHY SHOWN ON PLAN SHEETS IS INTENDED TO SHOW THE GENERAL LOCATION OF FENCES, CULVERTS, DRIVES, EXISTING UTILITIES, POINTS OF CONNECTION, ETC. HOWEVER; THE EXACT LOCATION AND QUANTITIES SHALL BE VERIFIED AT THE TIME OF CONSTRUCTION. 2. THE HORIZONTAL LOCATION DATA IS BASED UPON THE INDIANA STATE PLANE COORDINATE SYSTEM (WEST ZONE) REFERENCED TO THE 1983 NORTH AMERICA DATUM (NAD83) ELEVATIONS ARE BASED UPON THE 1988 NORTH AMERICAN VERTICAL DATUM (NAVO 88) 3. THE CONTRACTOR SHALL CALL INDIANA UNDERGROUND SERVICES AT 1-800-382-5544 PRIOR TO ANY CONSTRUCTION TWO FULL WORKING DAYS BEFORE CONSTRUCTION IS TO BEGIN. 4. THE LOCATION OF EXISTING UTILITIES, ETC. SHOWN ON THESE PLANS ARE NOT THE EXACT LOCATIONS BUT ONLY A GENERAL LOCATION. ALTHOUGH THESE PLANS HAVE ATTEMPTED TO SHOW ALL EXISTING UTILITIES, THE CONTRACTOR SHALL NOT ASSUME ALL EXISTING UTILITIES HAVE BEEN SHOWN. THEREFORE IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO SEE THAT ALL EXISTING UTILITIES WITHIN CONSTRUCTION AREAS ARE CLEARLY MARKED IN THE FIELD PRIOR TO ANY CONSTRUCTION IN THE AREA 5. EXACT LOCATION OF PLUG VALVES, CLEAN OUTS, AIR RELIEF VALVES, ETC. TO BE DETERMINED AT THE TIME OF CONSTRUCTION. 6. DOWN TIME COORDINATION MUST BE MADE WITH THE SEWER UTILITY PRIOR TO TEMPORARILY SHUTTING DOWN/ CONNECTING TO EXISTING SEWER MAINS OR LIFT STATIONS. COORDINATE WITH JOSH WALKER, WASTEWATER SUPERINTENDENT, AT 1-812-678-5171, A MINIMUM OF FIVE (5) WORKING DAYS PRIOR TO TEMPORARILY SHUTTING DOWN/ CONNECTING TO EXISTING SEWER MAINS, LIFT STATIONS, OR EQUALIZATION TANK. 7. PROPERTY LINES, WHERE SHOWN, ARE BASED ON COUNTY PLAT RECORDS. THE SAID PROPERTY LINES ON THESE SHEETS DO NOT REPRESENT THE PROPERTY SURVEYS, BUT ARE ONLY APPROXIMATE LOCATIONS FOR REFERENCE PURPOSES ONLY. 8. IF ANY ARCHAEOLOGICAL ARTIFACTS OR HUMAN REMAINS ARE UNCOVERED DURING CONSTRUCTION, THE CONTRACTOR SHALL STOP ALL EXCAVATION WORK AND CONTACT THE INDIANA DEPARTMENT OF NATURAL RESOURCES, DIVISION OF HISTORIC PRESERVATION AND ARCHEOLOGY AT 1-317-232-1646. NO ADDITIONAL EXCAVATION WORK SHALL BE DONE WITHOUT RECEIVING THEIR APPROVAL. 9. THE CONTRACTOR SHALL BE REQUIRED TO IMPLEMENT DUST CONTROL MEASURE (SURFACE WETTING) AS NECESSARY TO MINIMIZE FUGITIVE DUST EMISSIONS. 10. IF CAVERNS OR SPRINGS ARE ENCOUNTERED DURING EXCAVATION, WORK SHALL STOP IMMEDIATELY AND THE INDIANA DEPARTMENT OF NATURAL RESOURCES OR THE U.S. FISH & WILDLIFE OFFICE SHALL BE CONTACTED CONCERNING PROPER MITIGATION MEASURES. 11. THE CONTRACTOR SHALL AVOID IN-CHANNEL WORK (AT STREAM CROSSINGS) DURING THE FISH SPAWNING SEASON (APRIL 1 THRU JUNE 30) WITHOUT PRIOR WRITTEN APPROVAL OF THE INDIANA DEPARTMENT OF NATURAL RESOURCES - DIVISION OF FISH AND WILDLIFE. LEGEND PROPOSED w_ SANITARY SEWER ::::..J'- - PROPOSED SEWAGE FORCEMAIN, SIZE AND FLOW DIRECTION � PROPOSED AIR RELIEF VALVE " PROPOSED PLUG VALVE Q PROPOSED CLEANOUT � PROPOSED FLUSHING CONNECTION EXISTING WATER t EXISTING 3-WAY FIRE HYDRANT AND VALVE l EXISTING 2-WAY FIRE HYDRANT AND VALVE t EXISTING FLUSH HYDRANT AND VALVE vf YARD HYDRANT ; EXISTING BLOW OFF AND VALVE 6 PRESSURE REDUCING VALVE [!J EXISTING LEAK DETECTION DEVICE " WATER METER s• SPRINKLER HEAD " EXISTING GATE VALVE @ EXISTING BUTTERFLY VALVE 0 EXISTING CHECK VALVE m EXISTING CURB STOP EXISTING WATER MAIN AND SIZE - ,w -- - - ow - - - SANITARY SEWER ___,,,___ FORCE MAIN WARNING/ LOCATE POST � EXISTING AIR RELIEF VALVE @8 LIFT STATION AND VALVE PIT -2 CLEAN OUT " EXISTING SANITARY VALVE 8 SANITARY MANHOLE @) SANITARY GRINDER PUMP SANITARY MAIN/ FORCE MAIN ELECTRICAL El ELECTRICAL PEDESTAL 01 ELECTRICAL METER -¢-!); LIGHT POLE \s\-----< UTILITY POLE WITH GUY BURIED ELECTRIC , __ OVERHEAD ELECTRIC -- OHE-- TELECOMMUNICATIONS ----fil--.. TELEPHONE PEDESTAL -so- FIBER OPTIC WARNING/ LOCATE POST lf,J TELEVISION PEDESTAL BURIED TELEPHONE , __ GAS � GAS WARNING/ LOCATE POST Ii EXISTING GAS VALVE 'o/ GAS METER GAS MAIN AND SERVICE LINE --0----0-- SURVEY ♦ SURVEY POINT/ BENCH MARK & SURVEY MONUMENT 'v HIGH WATER MARK STORM SEWER ® 1II11 STORM STRUCTURES >-'c�'�-< CULVERT TYPE AND SIZE @) STORM MANHOLE MISCELLANEOUS ® SIGN • SATELLITE DISH a RIGHT OF WAY MARKER □ MAIL BOX 0 POST 9 MANHOLE • REDUCER .,, CAP TREE WOOD FENCE _, __ ,_ WIRE FENCE _, ___ ,_ ELECTRIC FENCE , ___ CHAIN LINK FENCE HOUSE I H.T. I HOUSE TRAILER PLAN SHEET INFORMATION REV1SIONS BID SET C 2023 Midw�,1�n, f:11jlil1l-.::r. s. In<:. 802 Wcs1 Broadway Sire-et P.O. Box 295 Loogootee. lndbn« 47553 DATE JULY. 2023 DESIGN J.W.W. DRAWN C.Z.M. Q.C. CHECK PROJECT NUMBER 2021005-14 2 2 OF 11 Fll£ NU.BER 30 11 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2