Midwestern Engineers, Inc. Plan Preview

0 z i < = Cl C � t = = < "' � � z w z 0 w �' z 0 0 "' 0 z w a' " �I w " z � w < oc mW ;5 �� $0 i � . �" "9' •w '�Iii --1-" " o 0 -........ a:� QI>\ � 0 w u , •. m� � �l) a - < 'N 0 Q :S-5 o m <c \\ \\ \. __ , \ \\ \ \ \ \ \ I \ \\ \ \ \\ \ \ \ \ \ \ \ - r--- 1 I I I I I I I I I \\ : \\ I .I \ \ \\ \ \ \ \ I I I \\ \\ \\ \\ \ \ I \ I \ \ \ \ \ EXISTIN1,a"WATER MAIN BY _).\ DUBOIS WATER 1 UTILITIES INC. \\ \ \\ \, ' .�'\ \ '' \\ / I \\ \ I \\ \ I \ I I I I \ I \\ / I \\ \ II \\ CULTIYATED FIELD I I I ' ' \ \ I \ \ \ \ \ . I I I \ \ \ I \ \ \ \\ \\ \ I I \ \ \ I I I \ I I \ I I \ \_ \ \ I I I I I I I I I I \\ \\ \\ \ \ \ \\ \ \ \\ \\ \\ \\ \\ \ -... ' ' -z_ EX. TELEPHONE POLE EXISTING 12" GRAVITY SANITARY - - SEWER MAIN STONE EXISTING LIFT STATION No. 35E WET-WELL 1. 2. 3. CULTIVA'fED FIELD I CONTRACTOR TO REMOVE EXISTING SULZER XFP 100J-CB2 PUMP AND REPLACE IT WITH NEW FLYGT, MODEL NP 3202, HT3 468 PUMP CONTRACTOR TO REMOVE THE EXISTING IMPELLER FROM FLYGT, MODEL NP3202 PUMP AND REPLACE IT WITH NEW 468 (316MM) IMPELLER CONTRACTOR TO ADJUST EXISTING FLOATS PER LIFT STATION SCHEDULE (SEE SHEET No. 21 FOR DETAILS) EXISTING LIFT STATION No. 35E VALVE VAULT ) / I I ( I I / I ( / / __ __,, / / // / GRASS -- - --- 10 ---- EX. LIGHJ.EQLE- - - - -- - - ------------ ..___ --- -- ------------- / I / GRASS '----- ,-- •• --- -----------480---- _\ . ---- ----- - - - - EXISTING 8" PVC FORCE MAIN ., ' if ,..,... --- -- ,.,. \'\ -/jl-- --------,..__ - 1 �-11- - -------- --- �------=�----\----= ,,,.,✓ ,,...\t_____ ----- - -- - - -...... --- .... _Jill_ ----- EXISTING 8" WATER MAIN BY DUBOIS WATER UTILITIES INC. ..__ ' ' \ I I I \ I I I \ I \ I I I I I I \\ \\ \\ \\ \\ \ \ \\ I I 11 I I 11 II I I 11 I I I I II /, II II / 1/ II \---, \ II, 1 1 1 i II \ \ l II \ \ 1 " '\ II \ \ II \ II 1 1 / \ II � • � - - ' li SE�R MAIN II \ II II II \ 1/ ..__ 1 I \ \ ----- ' \ \ ---- -- - - 479 CONTRACTOR TO REMOVE AND REPLACE THE EXISTING CHECK VALVES AND PLUG VALVES / ' \ ) / / / \ I I I - __.. -480 - - - -- ---- _...--GRASS - 481 ' I I \ I I I I I I I I -.._ ' ..__ ..__ -- --- -- -.._ \ LEGEND: D � L..:.._.:__J CJ � -530- - - - --�,!--- ---u;,·--- = = 12• SAN = = = !....- 12· SAN = = 10• F/t.l === === 10" F/M C::= EXISTING STRUCTURES EXISTING CONCRETE STRUCTURE OR SURFACE PROPOSED CONCRETE STRUCTURE OR SURFACE EXISTING STONE DRIVE OR SURFACE PROPOSED STONE DRIVE OR SURFACE EXISTING CONTOURS PROPOSED CONTOURS UNDERGROUND ELECTRIC EXISTING SANITARY SEWER MAIN AND SIZE NEW SANITARY SEWER MAIN AND SIZE EXISTING SANITARY FORCE MAN AND SIZE NEW SANITARY FORCE MAIN AND SIZE GENERAL PLAN NOTES: 1, IT IS THE CONTRACTOR'S RESPONSIBILITY TO DISPOSE OF ALL DEMOLISHED MATERIALS. THE DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS. 2. THE OWNER HAS RIGHTS TO ALL DEMOLISHED MATERIALS (PUMPS, VALVES, PIPING, ETC.) CONTRACTOR TO COORDINATE SALVAGED ITEMS WITH OWNER PRIOR TO DEMOLITION WORK SALVAGED ITEMS SHALL BE LOADED BY THE CONTRACTOR ONTO THE OWNER'S TRUCKS. 3. THE EXISTING LIFT STATION SHALL REMAIN IN SERVICE DURING THE ENTIRETY OF THE PROJECT LIFT STATION 35E CONTROL PANEL MODIFICATIONS 1. CONTRACTOR SHALL DEMOLISH EXISTING SULZER PUMP MODULE AND ALL ASSOCIATED WIRING. 2. CONTRACTOR SHALL DEMOLISH TWO EXISTING MINI-CAS MODULES AND REPLACE WITH NEW FROM FLYGT. 3. CONTRACTOR SHALL PERFORM CONTROL PANEL MALIGNANCE INCLUDING FUNCTIONAL TESTING, TERMINATION TIGHTNESS AND CLEANING. 4. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL INFORMATION . cc-- cc-- &1:.. NEW MH1A � BM-1 � CP-1 SL-1 � ====:::::i [r] EXISTING CHAIN LINK FENCE PROPOSED CHAIN LINK FENCE EXISTING DITCH/ FLOW LINE EXISTING MANHOLE & NUMBER PROPOSED MANHOLE & NUMBER CONTROL POINT OR BENCH MARK LOCATION {SEE SCHEDULE) STRUCTURE LOCATION (SEE SCHEDULE) CULVERT POWER POLE wl GUY WIRE TRANSFORMER ELECTRICAL PANEL • ,.... REVlSI0NS BID SET C 2023 Midwe�tern Engineers. Inc. S02 West Bro:,dway St�el P.O. Box 295 LoogootN. lndi�na 47553 DATE JULY. 2023 DESIGN J.W.W. DRAWN C.Z.M. Q.C. CHECK PROJECT NU MBER 2021005-14 20 20 DF 30 EXISTING LIFT STATION No. 35E - MODIFICATION SITE PLAN l!:::1 1 Fl= LEN= U"BE= R ==::!JI! Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2