Midwestern Engineers, Inc. Plan Preview

I I I UTILITIES GENERAL NOTES I TOPOGRAPHY SHOWN ON PLAN SHEETS IS INTENDED TO SHOW THE GENERAL LOCATION OF FENCES, Electric: Gas: 1 CULVERTS, DRIVES, EXISTING UTILITIES, POINTS OF CONNECTION, ETC. HOWEVER; THE EXACT LOCATION -- Centerpoint Energy (South Electric) Community Natural Gas Company, Inc. AND QUANTITIES SHALL BE VERIFIED AT THE TIME OF CONSTRUCTION 1800 W. 26th Street 933 W. 3rd Street THE HORIZONTAL LOCATION DATA IS BASED UPON THE INDIANA STATE PLANE COORDINATE SYSTEM Muncie, IN 47302 Mt Carmel, IL 62863 2 (WEST ZONE) REFERENCED TO THE 1983 NORTH AMERICAN DATUM (NAO 83) ELEVATIONS ARE BASED ON PH: 765-287-2119 Contact: Curt Sanger publicproject@centerpointenergy.com PH 812-937-2376 THE 1988 NORTH AMERICAN VERTICAL DATUM (NAVO 88). bommunications: dale@communitynaturalgas.com 3 THE CONTRACTOR SHALL CALL INDIANA UNDERGROUND SERVICES AT 811 PRIOR TO ANY CONSTRUCTION TWO FULL WORKING DAYS BEFORE CONSTRUCTION IS TO BEGIN r:T&T - Distribution Water: THE LOCATION OF EXISTING UTILITIES ETC SHOWN ON THESE PLANS ARE NOT THE EXACT LOCATIONS AT&T Utility Coordination Town of Gentryville BUT ONLY A GENERAL LOCATION. ALTHOUGH THESE PLANS HAVE ATTEMPTED TO SHOW ALL EXISTING 09871@art.com 240 W. Boone St. UTILITIES, THE CONTRACTOR SHALL NOT ASSUME ALL EXISTING UTILITIES HAVE BEEN SHOWN Gentryville, IN 47537 4 THEREFORE IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO SEE THAT ALL EXISTING UTILITIES Telephone: Contact: Marty Brown WITHIN CONSTRUCTION AREAS ARE CLEARLY MARKED IN THE FIELD PRIOR TO ANY CONSTRUCTION IN Perry-Spencer Rural Telephone Coop., Inc. Gentryvilletwn@psci.net THE AREA. 11877 E. State Rd. 62 St. Meinrad, IN 47577 Sewer: THE CONTRACTOR SHALL BE REQUIRED TO IMPLEMENT DUST CONTROL MEASURES (SURFACE WETTING) Contact: Jim Ferguson Town of Santa Claus 5 AS NECESSARY TO MINIMIZE FUGITIVE DUST EMISSIONS ALL AREAS DISTURBED BY CONSTRUCTION PH· 812-357-2123 P.O. Box 92 SHALL BE SEEDED OR SODDED, UNLESS OTHERWISE SHOWN 90 North Holiday Blvd. THE CONTRACTOR SHALL NOTIFY, IN WRITING, THE ENGINEER OF ANY CHANGES, OMISSIONS, OR I Santa Claus, IN 47579 6 ERRORS FOUND ON THESE PLANS. PH: 812-544-3329 Contact: Russell Luthy ALL CONSTRUCTION METHODS & MATERIALS MUST CONFORM TO CURRENT STANDARDS AND 7 SPECIFICATIONS OF THE FEDERAL, STATE, COUNTY, CITY/TOWN, OR LOCAL REQUIREMENTS, WHICHEVER russ.Iuthy@townofsantaclaus.com HAS JURISDICTION FINAL GRADES AT THE PROJECT BOUNDARY SHALL MATCH EXISTING ELEVATIONS UNLESS OTHERWISE 8 SHOWN • 9 WHEN PERFORMING GRADING OPERATIONS DURING PERIODS OF WET WEATHER, PROVIDE ADEQUATE DEWATERING DRAINAGE AND GROUND WATER MANAGEMENT TO CONTROL MOISTURE OF SOILS d AFTER STRIPPING TOPSOIL, THE SUBGRADE SHOULD BE PROOF-ROLLED WITH AN ADEQUATELY LOADED rtln1Yan1111112119.., VEHICLE SUCH AS A FULLY LOADED TANDEM-AXLE DUMP TRUCK TO DETERMINE LOCATIONS OF ANY .... 10 POCKETS OF UNSUITABLE MATERIAL. AREAS EXCESSIVELY DEFLECTING SHOULD BE DELINEATED. RECOMMENDATIONS FOR DRYING, AMENDING, AND/OR REMOVAL OF ANY UNSUITABLE MATERIAL WITHIN THE PROPOSED PAVED AREAS WILL BE DETERMINED AT THE TIME OF CONSTRUCTION BY THE CONTRACTOR'S GEOTECHNICAL TESTING REPRESENTATIVE. 11 IT IS THE CONTRACTOR AND OWNERS RESPONSIBILITY TO PREPARE AND FILE FOR A CONSTRUCTION STORMWATER GENERAL PERMIT (CSGP) TO IDEM IF SOIL DISTURBANCE IS GREATER THAN ONE(1) ACRE. 12 CONTRACTOR/OWNER SHALL OBTAIN A COUNTY HIGHWAY PERMIT FOR ALL WORK WITHIN SPENCER LOCAL AGENCIES COUNTY, IN RIGHT OF WAY. 13 ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE SEEDED OR SODDED UNLESS OTHERWISE SHOWN. 14 PROVIDE POSITIVE DRAINAGE WITHOUT PONDING, IN ALL AREAS, AFTER INSTALLATION, CONTRACTOR TO INDIANA DEPARTMENT OF TRANSPORTATION SPENCER COUNTY HIGHWAY DEPARTMENT TEST FOR, AND CORRECT, IF ANY, "BIRD BATH" CONDITIONS Vincennes District Dale Kenney, Highway Superintendent 3650 U.S. Highway 41 920 E 800 N Vincennes. IN 47519 Chrisney, IN 47611 PH; 812-882-8330 PH 812-362-8331 swincommunications@indotin.gov AUDITOR District Permit Manager Melissa Bunner Sara Polmanter 200 Main Street, Courthouse Rm 6 PH: 812-381-4566 Rockport, IN 47635 spolmanter@indot.in.gov PH: 812-649-6004 SPENCER COUNTY COMMISSIONERS James Seiler - District 1 2467 N Orchard Road Rockport, IN 47635 PH: 812-686-3102 Heather Gries - District 2 4970 E CR 2100 N Dale, IN 47523 PH: 812-630-5113 Thomas Brown - District 3 6378 E CR 700 N Grandview, IN 47615 PH. 812-686-6251 EARTHWORK QUANTITIES CUT (cy) FILL (cy) NET (cy) I 1376 1840 464 ' NOTE: EARTHWORK QUANTITIES ARE UNADJUSTED. CONTRACTOR TO COORDINATE WITH OWNER FOR DISPOSAL OF EXCESS MATERIAL. ' ' ' ' • SHEET NO. 1 2 3 4-5 6-12 13-19 20-21 22-26 27-28 SHEET NO. LEGEND WATER t EXISTING 3-WAY FIRE HYDRANT AND VALVE l EXISTING 2-WAY FIRE HYDRANT AND VALVE t EXISTING FLUSH HYDRANT AND VALVE yf YARD HYDRANT ; EXISTING BLOW OFF AND VALVE g PRESSURE REDUCING VALVE c:i EXISTING LEAK DETECTION DEVICE " WATER METER SH SPRINKLER HEAD 8 EXISTING GATE VALVE ® EXISTING BUTTERFLY VALVE 0 EXISTING CHECK VALVE � EXISTING CURB STOP EXISTING WATER MAIN AND SIZE w \_4" SANITARY SEWER --- FORCE MAIN WARNING/ LOCATE POST � EXISTING AIR RELIEF VALVE @@ LIFT STATION AND VALVE PIT _SJ CLEAN OUT 8 EXISTING SANITARY VALVE 8 SANITARY MANHOLE @ SANITARY GRINDER PUMP SANITARY MAIN/ FORCE MAIN SAN FIM SHEET INDEX DESIGNATION COVER INDEX AND GENERAL NOTES TYPICAL SECTIONS AND OVERALL MAP TYPICAL DETAILS PLAN AND PROFILE, LINE "PR-A'' SECTIONS, LINE "PR-A" CURB RAMP DETAILS EROSION CONTROL BRIDGE DETAILS REVISIONS DATE REVISED ELECTRICAL STORM SEWER B ELECTRICAL PEDESTAL Q]DcrJ]] STORM STRUCTURES '" ELECTRICAL METER >-,ri.�-< CULVERT TYPE AND SIZE -¢"* LIGHT POLE 8 STORM MANHOLE � UTILITY POLE WITH GUY BURIED ELECTRIC MISCELLANEOUS UIE OVERHEAD ELECTRIC ® SIGN OHE SATELLITE DISH TELECOMMUNICATIONS El RIGHT OF WAY MARKER MAIL BOX --- TELEPHONE PEDESTAL 0 POST �Fo� FIBER OPTIC WARNING/ LOCATE POST 8 MANHOLE "" TELEVISION PEDESTAL REDUCER • BURIED COMMUNICATION LINE CAP COMM -a @ TREE GAS WOOD FENCE I 41-- GAS WARNING/ LOCATE POST WIRE FENCE X 3 EXISTING GAS VALVE ELECTRIC FENCE 'ii' GAS METER E CHAIN LINK FENCE GAS MAIN AND SERVICE LINE CL GAS E] HOUSE SURVEY I H.T. I HOUSE TRAILER + SURVEY POINT/ BENCH MARK RIGHT OF WAY R/W & SURVEY MONUMENT PROPERTY LINE v HIGH WATER MARK ,PL - INDEX AND GENERAL NOTES SI' SI' 1- ...J z ...J 00 � :g I- «> >- 0 a:: z w > 1oz (.) ,:i: Cl) a:: Q (!) z z ...J REVISIONS 0311412025 BID SET C 2025 Midwc�1em Engineer.;. Inc. 801 Wc_s1 Broadway Str�N P.O. Box 295 Loo�oolec, ]ndiana 47553 DATE MARCH 2025 DESIGN C.W.R. /_ B.D.H DRAWN M.M.C. 0.C. CHECK R.A.B. PROJECT NUMBER 2024079-00 2 2 OF 29 I Fll.E NUMBER I 44608 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2