Midwestern Engineers, Inc. Plan Preview

CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS 1'-2" 1'-2" 1'-2" 60'-0" 1'-2" 1'-2" 60'-0" 1'-2" 1'-2" 26'-6" 1'-2" 3'-6" 3'-6" 31'-4" M M STATE OF N 19800122 J O H N W . W E T Z E L P R O F E S S I O N A L E N G I N E E R R E G I S T E R E D I N D I A N A o P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern 2019 9/18/19 BID SET Author: TKIDWELL, Plot Date: 10/10/2019 3:35 PM Path: Z:\CAD_INCOMPLETE\2018022-00_CITY OF HUNTINGBURG_WS_DISTRIBUTION SYSTEM IMPROVEMENTS AND PLANT UPGRADES\025_PRODUCTIONDWG_DIV 2\12 - MASTER MECHANICAL PLANS.DWG WATER SYSTEM IMPROVEMENTS DIV. II - WATER TREATMENT PLANT IMPROVEMENTS FOR THE CITY OF HUNTINGBURG DUBOIS COUNTY, INDIANA MECHANICAL CLARIFIER BLOW-DOWN / BACKWASH TANK PLAN VIEW SCALE: 1/4" = 1'-0" INV. 458.8 INV. 462.4 INV. 458.8 INV. 462.4 EXISTING 4" WATER EX. 12" PVC STORM DRAIN EX. 4" WATER EX. 8" D.I. SLUDGE LINE FROM CLARIFIERS EX. 16" D.I. BACKWASH LINE FROM FILTERS NEW CLARIFIERS BLOW-DOWN TANK EX. CLARIFIERS BLOW-DOWN TANK EX. BACKWASH HOLDING TANK 10" WALL PIPE (MJ x FLANGED) INV. 462.0 INV. 458.5 10" WALL PIPE (MJ x FLANGED) INV. 462.0 INV. 458.5 10" DI CL-350 PIPE REPLACE VALVE EXTENSION STEM AND HANDWHEEL OPERATOR ON EX. 10" PLUG VALVE (TYPICAL OF 4) REPLACE EX. 3'x3' SLIDE GATE, STEM WITH HAND CRANK OPERATOR (TYPICAL OF 2) REPLACE EX. 2'x2' SLIDE GATE, STEM WITH HAND CRANK OPERATOR NEW 10" x10"x10" D.I. TEE AND NEW 10" PLUG VALVE WITH HANDWHEEL OPERATOR (TYPICAL OF 4) CUT IN 24"x24" OPENING IN EX. WALL CONTRACTOR SHALL BE REQUIRED TO PROVIDE ANY TEMPORARY PIPING NECESSARY TO ALLOW FILTER BACKWASH TO BE DIVERTED TO THE EX. CLARIFIER BLOW-DOWN TANK DURING THE CONSTRUCTION OF THIS NEW WALL OPENING NEW 24"x24" OPENING IN NEW WALL NEW 2'x2' SLIDE GATE CUT IN 12" DIA. OPENING IN EX. WALL (TYP OF 2) WITH LINK-SEAL CUT IN 12" DIA. OPENING IN EX. WALL (TYP OF 2) WITH LINK-SEAL EX. 8" D.I. TEE EX. 8" WALL PIPE (MJxFLANGED) EX. 16" WALL PIPE (MJxFLANGED) INV. 462.0 INV. 462.0 NEW 8"x8"x8" D.I. TEE (FLANGED) INV. 462.0 NEW 16"x16"x16" D.I. TEE (FLANGED) INV. 462.0 NEW 8" WALL PIPE (MJxFLANGED) NEW 16" WALL PIPE (MJxFLANGED) 1 2 3 1 2 4 7 6 5 4 2 8 9 10 8 9 11 12 9 13 12 11 9 1 C3.04 PIPING KEY 1 8" D.I. CL-350 PIPE W/ POLY. ENCASEMENT 2 8" SERIES 1100 MEGA-LUG 3 8" D.I. 90° ELBOW 4 8" PLUG-VALVE 5 8" ANCHOR COUPLING 6 8"x8"x8" D.I. TEE 7 8" D.I. SLEEVE 8 16" D.I. CL-250 PIPE W/ POLY. ENCASEMENT 9 16" SERIES 1100 MEGA-LUG 10 16" D.I. 90° ELBOW 11 16" BUTTERFLY VALVE 12 16" ANCHOR COUPLING 13 16"x16"x16" D.I. TEE 14 16" D.I. SLEEVE NEW BACKWASH HOLDING TANK 2 C3.04 SLOPE SLOPE SLOPE SLOPE 2 8 5 1 14 3 C3.04 10" DI CL-350 PIPE C3.03 37 39493 4 C3.04 SEE SHEET C3.04 FOR SUMP PIPING KEY CUT IN 24"x24" OPENING IN EX. WALL NEW 24"x24" OPENING IN NEW WALL NEW 2'x2' SLIDE GATE LEGEND EXISTING PIPING PROPOSED PIPING SEE SHEET C3.04 FOR DEMOLITION OF EXISTING PIPING INV. 458.5 REMOVE EX. 16" D.I. 90° ELBOW AND REPLACE WITH 16"x16"x16" D.I. TEE (FLANGED) 6" D.I. CL-350 PIPE W/ POLYETHYLENE ENCASEMENT FROM DRYING BEDS CAP/PLUG EX. WALL SLEEVE REPLACE EX. GRATE WITH SLATE GRAY MEDIUM GRIT FINISH FRP PANEL SYSTEM SIMILAR OR EQUAL TO "STRONG WELL" UTILICOVER (2" DEEP x 24" WIDE x 6' LONG PANELS) REMOVE EXISTING GUARDRAIL REMOVE EXISTING GUARDRAIL Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2