Midwestern Engineers, Inc. Plan Preview
NOT TO SCALE SODIUM PERMANGANATE SYSTEM SCHEMATIC GLOBE VALVE GATE VALVE CHECK VALVE PLUG VALVE BALL VALVE VALVE SYMBOLS CALIBRATION COLUMN POTABLE WATER FLOW METER 2" TANK MIXER (TYP. OF 2) DRAIN LINE (TYP.) PRESSURE TRANSMITTER / TRANSDUCER (TYP.) 3 4 " 3 4 " AIR GAP TO DRAIN (TYP.) OVERFLOW LINE (TYP.) 3 4 " 3 4 " STRAINER (TYP. OF 2) METERING PUMP (TYP. OF 2) PULSATION DAMPENER (TYP.) PRESSURE RELIEF VALVE (TYP.) 1 2 " TO INFLUENT LINE INJECTION POINT TO INTAKE STRUCTURE 3 4 " 3 4 " 1" 1" BACK PRESSURE VALVE (TYP.) NOT TO SCALE POWDERED ACTIVATED CARBON (GRANULAR) SYSTEM SCHEMATIC LIVE BOTTOM BIN VOLUMETRIC SCREW FEEDER 1 2 HP 1 2 HP 230/460/3/60 H/O/A 3 4 " HP 115/1/60 SC HS HS LOCAL/ REMOTE START/ STOP <4-20MA LIVE BOTTOM BIN VOLUMETRIC SCREW FEEDER 1 2 HP 1 2 HP 230/460/3/60 H/O/A 3 4 " HP 115/1/60 SC HS HS LOCAL/ REMOTE START/ STOP <4-20MA S WATER SUPPLY TO INFLUENT LINE INJECTION POINT EDUCTOR 3 4 " 3 4 " WETTING CONE GLOBE VALVE (TYP.) 1 4 " NOT TO SCALE LIME SYSTEM SCHEMATIC HARD PIPE TO DRAIN (SCH.80 PVC, 6") FSL FI M S P LAL LT LE LSH LAH 1" BALL VALVE 1" FLOW METER HOSE BIBB FLOW INDICATOR STRAINER/ PRESSURE REGULATOR PRESSURE INDICATOR SOLENOID VALVE GLOBE VALVE (TYP.) ASPIRATOR CONTROL WATER VENT FLOW SWITCH MIXER SLURRY TANK OPEN CHANNEL TO APPLICATION POINTS OVERFLOW LEVEL ELEMENT LEVEL TRANSMITTER LOW - LOW LEVEL ALARM HIGH - HIGH LEVEL ALARM HIGH - HIGH LEVEL SENSOR NOT TO SCALE SODIUM FLUORIDE SYSTEM SCHEMATIC METERING PUMP NO. 1 METERING PUMP NO. 2 (BACK UP) PULSATION DAMPENER CALIBRATION COLUMN BACK PRESSURE VALVE SHELF GLOBE VALVE (TYP. EA. PUMP EFF. LINE) 6" OVERFLOW WITH AIR GAP TO DRAIN SUCTION MANIFOLD AND FOOT VALVE UPFLOW SATURATOR SODIUM FLUORIDE SATURATED FLUORIDE SOLUTION 3 4 " WATER METER SAMPLE VALVE PRESSURE REGULATOR/ FLOW RESTRICTOR VACUUM BREAKER SOLENOID VALVE POWER SUPPLY 66 GAL. CONTAINMENT PALLET CONTROL PANEL SUPPLY FOR LIME STATE OF N 19800122 J O H N W . W E T Z E L P R O F E S S I O N A L E N G I N E E R R E G I S T E R E D I N D I A N A o P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern 2019 9/18/19 BID SET Author: KGAINES, Plot Date: 10/4/2019 9:35 AM Path: Z:\CAD_INCOMPLETE\2018022-00_CITY OF HUNTINGBURG_WS_DISTRIBUTION SYSTEM IMPROVEMENTS AND PLANT UPGRADES\025_PRODUCTIONDWG_DIV 2\42-43 CHEM FEED SCHEMATIC.DWG WATER SYSTEM IMPROVEMENTS DIV. II - WATER TREATMENT PLANT IMPROVEMENTS FOR THE CITY OF HUNTINGBURG DUBOIS COUNTY, INDIANA CFS.01 39488 EXISTING CHEMICAL FEED SYSTEM SCHEMATICS (DEMOLITION) DO NOT SCALE NOTE: · ALL CHEMICAL FEED LINES, EQUIPMENT, AND OTHER APPURTENANCES SHOWN WITH RED CROSS HATCH TO BE REMOVED AND DISPOSED OF IN ACCORDANCE TO LOCAL, STATE AND FEDERAL REGULATIONS. · THE OWNER HAS RIGHTS TO ALL DEMOLISHED MATERIALS. CONTRACTOR TO COORDINATE SALVAGED ITEMS WITH OWNER PRIOR TO ANY DEMOLITION WORK. SALVAGED ITEMS SHALL BE STORED ON SITE AS DIRECTED BY OWNER. FEED LINE SHALL BE CONVERTED TO RAW WATER SAMPLE LINE SEE SHEET GC.03 FOR SITE LOCATION SEE SHEETS CFS.03 AND CFS.07 FOR FURTHER DETAIL REMOVE SHAKER STAND. CUT BOLTS FLUSH WITH FLOOR AND PATCH CONCRETE AS NECESSARY CUT, CAP AND PLUG AS NECESSARY REMOVE EXISTING WATER LINE AND METER BACK TO CONNECTION W/ 3" HEADER MAIN. CUT/CAP AND PLUG AS REQUIRED REMOVE EXISTING SODIUM PERMANGANATE FEED LINE FROM THIS POINT TO THE INJECTION POINT IN THE INFLUENT FLOW MAIN, INCLUSIVE OF THE INJECTOR/QUILL. NOTE: THE ENTIRE SODIUM PERMANGANATE FEED SYSTEM WILL BE REMOVED/RETIRED. THE NEW SODIUM PERMANGANATE SYSTEM SHALL BE OPERATIONAL PRIOR TO REMOVAL/RETIREMENT OF THE EXISTING SYSTEM. EXISTING CARBON FEED LINE WILL BE REUSED NOTE: THE ENTIRE P.A.C. FEED SYSTEM IS INTEGRAL TO THE OPERATION OF THE WATER TREATMENT PLANT. CONTRACTOR SHALL COORDINATE WITH OWNER TO ENSURE THAT OPERATION OF THE FEED SYSTEM IS MAINTAINED DURING THE ENTIRETY OF THE DEMOLITION/REWORK PERIOD REMOVE EXISTING WATER LINE TO PAC/LIME ROOM ENTRANCE. CUT/CAP/PLUG EX. LINE AS NECESSARY. SEE CFS.05 FOR FURTHER DETAIL NOTE: THE LIME SYSTEM IS NOT CURRENTLY IN OPERATION. THE ENTIRE SYSTEM SHALL BE REMOVED. REMOVE EXISTING WATER LINE FROM CHLORINATION SYSTEM SOFTENERS. CUT/CAP/PLUG WATER MAIN AT EXISTING SOFTENERS REMOVE EXISTING SODIUM FLUORIDE FEED LINE FROM THIS POINT TO THE INJECTION POINTS IN THE CHEMICAL MIXING ZONE PRIOR TO THE CLEARWELL, INCLUSIVE OF THE DIFFUSERS NOTE: THE ENTIRE SODIUM FLUORIDE FEED SYSTEM WILL BE REMOVED/RETIRED. THE NEW SODIUM FLUORIDE FEED SYSTEM SHALL BE OPERATIONAL PRIOR TO REMOVAL/RETIREMENT OF THE EXISTING SYSTEM. NOTE: ALL POWER OR CONTROL WIRING ASSOCIATED WITH CHEMICAL FEED SYSTEMS OR EQUIPMENT BEING DEMOLISHED WITHIN THE SCOPE OF THIS PROJECT SHALL BE REMOVED, CONDUITS SHALL BE CAPPED AND MARKED AS "SPARE" THEN ABANDONED IN PLACE ONCE EMPTY. Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2