2 RUNS (4) #350 MCM (1) #1 CU. GND. 3" CONDUIT 1200A-3P w/ GROUND FAULT 1 EXISTING 1200A-3P, 277/480V-3Ø, 4W, MAIN POWER DISTRIBUTION PANEL "MDPXA" REQ. No. 374, JOB No. 178, NEMA 1 ENCLOSURE, IN MAIN ELECTRICAL ROOM 1200A-3P 2 600A-3P 3 4 5 6 8 125A-3P 250A-3P 250A-3P 7 200A-3P SPARE 120/208V 3Ø, 4W 60A MCB 12CKT 15KVA PANEL "LXC" SPACE 9 125A-3P 10 100A-3P 11 100A-3P 12 13 80A-3P 14 60A-3P 15 50A-3P 16 30A-3P 17 40A-3P 120/208V 3Ø, 4W 200A MCB 42CKT 75KVA PANEL "LXA" SPARE SPARE 120/208V 3Ø, 4W 200A MCB 42CKT 75KVA 120/208V 3Ø, 4W 200A MLO 42CKT #3/0 GROUNDING ELECTRODE CONDUCTOR IN 1" CONDUIT 277/480V-3Ø GENERAC 350KW STANDBY DIESEL GENERATOR MODEL No. 3200520200 SERIAL No. 2072354 ENGINE No. 0A8829 4 RUNS (4) #350 MCM 3" CONDUIT 4 RUNS (4) #350 MCM (1) #3/0 CU. GND. 3" CONDUIT 600A-3P 4 RUNS (4) #350 MCM (1) #3/0 CU. GND. 3" CONDUIT 1200A-3P, 277/480V-3Ø, 4W MAIN DISTRIBUTION PANEL "MDP" REQ. No. 374 JOB No. 178 NEMA 1 ENCLOSURE 1200A-3P ASCO SERIES 7000 NON-AUTOMATIC TRANSFER SWITCH IN NEMA 1 ENCLOSURE CAT. No.H07ATSC31200N5XC BOM No. 735883 SERIAL No. 215299 FP S/O No. 138522 60A-3P SPD 400A-3P OFF OFF SPARE 480V-3Ø 21 FLA BLOWER #1 15HP NEMA SIZE 2 40A-3P 70A-3P 25KVA-1Ø PANEL "LG" OFF SPARE CONTROL PANEL 37.5KVA-1Ø LIGHTS FIRST FLOOR WTP SPARE 5KW 480V-3Ø 7.5 FLA ELECTRIC ROOM UNIT HEATER 1 100A-3P, 277/480V-3Ø, 4W MAIN LUG ONLY POWER DISTRIBUTION PANEL "HXA" IN ELECTRICAL ROOM 20A-1P 20A-1P 100A-3P 3 20A-1P 4 20A-1P 5 20A-1P 6 25A-1P 7,9,11 20A-1P 8 2 20A-1P 20A-1P 9-16 15,17,19 20A-3P 18,20,22 21,23,25 LIGHTS SECOND FLOOR WTP LIGHTS FIRST FLOOR WTP LIGHTS SECOND LEVEL GARAGE LIGHTS FIRST FLOOR WTP LIGHTS EXTERIOR LIGHTS SITE POLE LIGHTS PANEL "LXB" PANEL "LXD" 2 RUNS (3) #400 MCM THWN (1) #1 CU. GND. 4" CONDUIT PROPOSED EQUIPMENT, CONDUIT AND WIRE EXISTING TO REMAIN, MODIFY AS REQUIRED FOR FULLY FUNCTIONAL SYSTEM LEGEND 100HP 480V-3Ø 124 FLA H.S. PUMP #1 225A-3P 100HP 480V-3Ø 124 FLA H.S. PUMP #2 225A-3P 50HP 480V-3Ø 65 FLA RAW PUMP #1 125A-3P 30A-3P PROPOSED 600A MCB, 277/480V-3Ø MAIN POWER DISTRIBUTION PANEL "B "(MDPB), SQ.D I-LINE, 54" BREAKER MOUNTING SPACE, INTEGRALL TVSS, COPPER BUSSING, NEMA 1 ENCLOSURE IN HIGH SERVICE PUMP BUILDING 1 2 3 4 5 PANEL "LXC" TO BE RELOCATED 600A-3P 480V-3Ø 65 FLA RAW PUMP #2 5 4 8 9 5 7 10 11 5 12 60A MCB 18 CKT SPD 6 125A-3P 50HP 3 4 NEW 480V-3Ø PUMP CABLING PROVIDED AND INSTALLED BY CONTRACTOR 125A-3P 7 6 1 2 4 8 10 12 4 5 9 5 11 5 20KW 480V-3Ø ALUM ROOM UNIT HEATER w/ INTEGRAL DISC. 16 18KW 480V-3Ø MIOX WATER HEATER 480V-3Ø 7.6 FLA SLUDGE PUMP #1 5HP NEMA SIZE 0 17 17 480V-3Ø 7.6 FLA SLUDGE PUMP #2 5HP NEMA SIZE 0 17* 17 17 480V-3Ø 7.6 FLA SLUDGE PUMP #3 5HP NEMA SIZE 0 17* 17 17 16 16 18 20A-3P 20A-3P 20A-3P 24,26,28 19 19 19 480V-3Ø 2.1 FLA FLOCCULATOR CONTROL PANEL #5 1HP 2 21 17* 480V-3Ø 2.1 FLA FLOCCULATOR CONTROL PANEL #6 1HP 480V-3Ø 2.1 FLA FLOCCULATOR CONTROL PANEL #7 1HP 480V-3Ø 2.1 FLA FLOCCULATOR CONTROL PANEL #8 1HP 480V-3Ø 4.8 FLA LIFT 3HP 480V-3Ø 1.6 FLA (EA.) EXHAUST FANS 3, 4 & 6 5KW 480V-3Ø 7.5 FLA UNIT HEATER #1 480V-3Ø FLOCULATORS (EX. FILTERS 1-4) 5KW 480V-3Ø 7.5 FLA UNIT HEATER #2 5KW 480V-3Ø 7.5 FLA UNIT HEATER #6 5KW 480V-3Ø 7.5 FLA UNIT HEATER #4 1,3,5 225A-3P, 277/480V-3Ø, 4W MAIN LUG ONLY POWER DISTRIBUTION PANEL "HXB" IN ELECTRICAL ROOM 20A-3P 20A-3P 225A-3P 7,9,11 45A-3P 8,10,12 20A-3P 13,15,17 20A-3P 14,16,18 20A-3P 19,21,23 20A-3P 20,22,24 2,4,6 35A-3P 20A-3P 25,27,29 20A-3P 26,28,30 20A-3P 31,33,35 20A-3P 32,34,36 UNIT HEATER #3 20A-1P 37 UNIT HEATER #7 20A-1P 38 UNIT HEATER #5 20A-1P 39 40 41 42 SPACE 480V-3Ø 21 FLA PROPOSED BLOWER #2 15HP NEMA SIZE 2 2 14 2 SPACE PARKSON CONTROL PANEL (PCP2) 2 OSG SPACE EXISTING 277/480V-3Ø, 4W Y ELECTRIC SERVICE BY CITY OF HUNTINGBURG TO REMAIN NOTE: IF SEQUENCING OF CONSTRUCTION DOES NOT ALLOW EXISTING 600A MCC FEEDER TO BE REPURPOSED FOR H.S. PUMP BUILDING THE CONTRACTOR SHALL PROVIDE TEMPORARY POWER AS REQUIRED OR INSTALL NEW 600A BREAKER IN PLACE OF AN EXISTING MDPXA SPARE 4 4 15 15 4 4 18X 17 20 17 17 13 UNCLASSIFIED CLASS 1 DIV. 2 EXPLOSION PROOF INSIDE PAC ROOM POWDER ACTIVATED CARBON (PAC) EQUIPMENT REUSE EXISTING CONDUITS IF PERMISSIBLE BY NEC, PROVIDE NEW AS REQUIRED 17* 17* 17* VFD 21 21 21 17* 17* 17* VFD VFD VFD SPARE 17* REUSE EXISTING DISCONNECTS (TYP. OF 3) KEY NOTES (3) #1 THWN (1) #6 CU. GND. 1 1 2 " SCH. 80 PVC (3) #10 THWN (1) #10 CU. GND. 1" SCH. 80 PVC (4) #6 THWN (1) #10 CU. GND. 1" SCH. 80 PVC (3) #4 THWN (1) #6 CU. GND. 1 1 2 " SCH. 80 PVC (3) #2/0 THWN (1) #4 CU. GND. 2 1 2 " SCH. 80 PVC 1 2 10 TCI 100A HARMONIC GUARD ACTIVE FILTER w/ 125A-3P INTEGRAL CIRCUIT BREAKER AND APPLICABLE CT'S IN FLOOR MOUNT NEMA 1 ENCLOSURE MOUNTED TO A CONCRETE HOUSEKEEPING PAD EXISTING 15 KVA-3Ø TRANSFORMER TO BE RELOCATED AND RECONNECTED, 480V-3Ø PRIMARY, 120/208V-3Ø SECONDARY TCI KDR LINE REACTOR CAT. No. KDRF1HE01, 480V, 50HP, 65A. IN NEMA 1 ENCLOSURE MOUNTED TO CONCRETE HOUSEKEEPING PAD. TCI KDR LINE REACTOR CAT. No. KDRI2HE01, 480V, 100HP, 124A. IN NEMA 1 ENCLOSURE MOUNTED TO CONCRETE HOUSEKEEPING PAD. ABB VFD MODEL ACQ580-01-078A-4+K475 480V-3Ø, 50HP IN NEMA 1 ENCLOSURE ABB VFD MODEL ACQ580-01-156A-4+K475 480V-3Ø, 100HP IN NEMA 1 ENCLOSURE 100A-3P NON FUSIBLE DISCONNECT IN NEMA 4X S.S. ENCLOSURE THE EXISTING POWDER ACTIVATED CARBON EQUIPMENT IS TO BE REMOVED AND REPLACED WITHIN THE SCOPE OF THIS PROJECT. THE ELECTRICAL INSTALLATION ASSOCIATED WITH THIS PROCESS SHALL BE PER NEC AND MANUFACTURERS INSTALLATION REQUIREMENTS AS IT PERTAINS TO APPROVED SHOP DRAWING SUBMITTALS REVIEWED DURING CONSTRUCTION. NEMA SIZE 2 COMBINATION STARTER/NON-FUSIBLE DISCONNECT w/ SOLID STATE THERMAL OVERLOADS, H-O-A SELECTOR SWITCH, AUX START/RUN/FAIL CONTACTS AND ASSOCIATED 22MM PUSH-TO-TEST LED PILOT LIGHTS, GREEN-ON, RED-OFF, YELLOW-ALARM AND 120V CONTROL TRANSFORMER FOR LOADS AS SHOWN. CONTRACTOR SHALL INSTALL POWER FACTOR CORRECTION CAPACITORS TO >95% WITHOUT LEADING ON LOAD SIDE OF STARTER OUTSIDE OF NEMA 1 ENCLOSURE. TCI V1K DV/DT FILTER CAT. No. V1K80E01, 480V, 50 HP, 80A, IN NEMA 1 ENCLOSURE MOUNTED TO CONCRETE HOUSEKEEPING PAD. 6 7 8 9 11 12 3 4 13 14 15 5 (3) #8 THWN (1) #10 CU. GND. 1" SCH. 80 PVC (3) #12 THWN (1) #12 CU. GND. 1" SCH. 80 PVC (3) #12 THWN (1) #12 CU. GND. 1" ALUMINUM 16 17 17* 30A-3P NON-FUSIBLE DISCONNECT, NEMA 1 ENCLOSURE, 480V ("X" DENOTES EXPLOSION PROOF) NEMA SIZE 0 COMBINATION STARTER/NON-FUSIBLE DISCONNECT w/ SOLID STATE THERMAL OVERLOADS, H-O-A SELECTOR SWITCH, AUX START/RUN/FAIL CONTACTS AND ASSOCIATED 22MM PUSH-TO-TEST PILOT LIGHTS, GREEN-ON, RED-OFF, YELLOW-ALARM AND 120V CONTROL TRANSFORMER FOR LOADS AS SHOWN IN NEMA 1 ENCLOSURE. PROPOSED VFD SHALL BE IN NEMA 1 ENCLOSURE SIZED PER THE PAC EQUIPMENT MANUFACTURERS RATED EQUIPMENT FOR THE FEEDER AUGER. THE PROPOSED VFD SHALL BE EQUIPPED w/ HARDWIRED I/O PER SCADA I/O LISTS AND INSTALLED IN THE EXISTING LAB ADJACENT TO THE SLUDGE PUMP STARTERS PER PLANS w/ ALL APPLICABLE WIRING AS REQUIRED FOR A FULLY FUNCTIONAL SYSTEM. PROPOSED FLOCCULATOR CONTROL PANELS SHALL ESSENTIALLY MATCH EXISTING. NEMA 4X S.S. ENCLOSURE, INTEGRAL ROTARY DISCONNECT, VARIABLE FREQUENCY DRIVE w/ ALL POWER AND CONTROL AS REQUIRED FOR FULLY FUNCTIONAL SYSTEM. SEE SCADA I/O LISTS FOR ADDITIONAL REQUIREMENTS FOR INTEGRATION. 18 19 20 21 PROPOSED POWER DISTRIBUTION ONE LINE DIAGRAM NOT TO SCALE P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern 2019 BID SET Author: CMOODY, Plot Date: 10/4/2019 8:05 AM Path: Z:\CAD_INCOMPLETE\2018022-00_CITY OF HUNTINGBURG_WS_DISTRIBUTION SYSTEM IMPROVEMENTS AND PLANT UPGRADES\025_PRODUCTIONDWG_DIV 2\ONE LINE.DWG WATER SYSTEM IMPROVEMENTS DIV. II - WATER TREATMENT PLANT IMPROVEMENTS FOR THE CITY OF HUNTINGBURG DUBOIS COUNTY, INDIANA STATE OF No. PE11100002 A L A N F . B U R C H P R O F E S S I O N A L E N G I N E E R R E G I S T E R E D I N D I A N A E.11 39467 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2