Midwestern Engineers, Inc. Plan Preview

M STATE OF N 19800122 J O H N W . W E T Z E L P R O F E S S I O N A L E N G I N E E R R E G I S T E R E D I N D I A N A o P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern 2019 9/18/19 BID SET Author: DKOONTZ, Plot Date: 10/14/2019 7:28 AM Path: Z:\CAD_INCOMPLETE\2018022-00_CITY OF HUNTINGBURG_WS_DISTRIBUTION SYSTEM IMPROVEMENTS AND PLANT UPGRADES\025_PRODUCTIONDWG_DIV 2\05 - 08 SITE PLANS.DWG WATER SYSTEM IMPROVEMENTS DIV. II - WATER TREATMENT PLANT IMPROVEMENTS FOR THE CITY OF HUNTINGBURG DUBOIS COUNTY, INDIANA SITE PIPING PLAN SCALE: 1" = 40' 0 20 40 INSTALL TEMPORARY BYPASS PIPING AND DEMO EXISTING INTAKE PUMP STATION SEE DETAIL ON SHEET D1.01 EXISTING OUTFALL STRUCTURE HIGH SERVICE PUMP STATION 404,000 GALLON CLEARWELL MASTER METER CONNECTION TO DUFF WATER 12" WATER MAIN TO SYSTEM 8" WATER MAIN TO WTP EXISTING BLOW-DOWN TANK EXISTING BACKWASH TANK NEW SLUDGE DRYING BEDS ELEC. TRANSFORMER ELEC. BOX EXISTING MIXED OXIDANT DISINFECTANT AND AMMONIA CHEMICAL FEED LINES TO BE RETIRED IN PLACE SLUDGE BLOW-DOWN VALVE VAULT. SEE DETAIL ON SHEET C2.01 FOR MODIFICATIONS EX. 16" PIPE WITH 14" HDPE LINER 10" 8" MAG METER CONCRETE S.R. 64 HUNTINGBURG LAKE SAN. MH TOP 466.04 8" PVC INV. E.W.: 459.69 4" PVC INV. S.: 460.04 SAN. MH TOP 456.74 8" PVC INV. N.S.: 448.24 8" PVC INV. W.: 448.84 STM. MH TOP 467.22 12" PVC INV. 461.82 (3) 12" D.I. PIPES INV. 466.5 GC.03 39523 TWO (2) EX. 14" GATE VALVES 14" GATE VALVE WITH 14"x12" REDUCER 12" GATE VALVE EXISTING WATER TREATMENT PLANT BUILDING NEW INTAKE PUMP STATION. SEE SHEETS C1.01 AND C1.02 FOR DETAILS. DRYING BED No. 1 DRYING BED No. 2 DRYING BED No. 3 DRYING BED No. 4 NEW BLOW-DOWN TANK NEW BACKWASH TANK EX. STO. EX. STO. EXISTING PRESSURE TRANSDUCER PIT RAW WATER MAIN AND SIZE FINISHED WATER MAIN AND SIZE BY-PASS LINE AND SIZE FORCE MAIN AND SIZE BACKWASH LINES AND SIZE SLUDGE LINES AND SIZE STORM CATCH BASIN, SEWER AND SIZE SANITARY MANHOLE, SEWER AND SIZE WATER MAIN AND SIZE GAS MAIN AND SIZE EXISTING MAINS TO BE RETIRED IN PLACE PROPOSED MAINS, SHOWN AS BOLD EXISTING MAINS, SHOWN AS LIGHT UNDERGROUND ELECTRIC TELEPHONE NEW CHAIN LINK FENCE EXISTING CHAIN LINK FENCE MIXED OXIDANT DISINFECTION SOLUTION FEED LINE FLUSH HYDRANT PROPOSED / EXISTING VALVE SODIUM PERMANGANATE FEED LINE POWER POLE w/ GUY WIRE LEGEND WATER METER M SLUDGE DRAIN LINES AND SIZE SLUDGE WASTE LINES AND SIZE DRAIN LINE AND SIZE PERFORATED DRAIN TILE EX. CHEM. FEED LINE CONVERTED TO SAMPLE LINE EXISTING INTAKE STRUCTURE DIV. III - WTP IMPROVEMENTS SOLAR FIELD ADDITION (NOT PART OF THIS CONTRACT) NEW 6" SLUDGE WASTE LINE TO DRYING BEDS. SEE DETAILS ON SHEETS C4.01 THRU C4.03 NEW 6" SLUDGE DRYING BED DRAIN LINE TO NEW SAN. SEWER MANHOLE. SEE DETAILS ON SHEETS C4.01 THRU C4.03 NEW 6" PERFORATED DRAIN TILE. SEE DETAILS ON SHEETS C4.01 THRU C4.03 NEW 8" SLUDGE WASTE LINE TO SAN. SEWER. SEE DETAILS ON SHEETS C4.01 THRU C4.03 NEW BLOW-DOWN / BACKWASH TANK INFLUENT PIPING. SEE DETAILS ON SHEETS C2.01 THRU C2.03 INSTALL NEW 12" RCP CULVERT WITH CONCRETE END SECTIONS. SEE DETAILS ON SITE GRADING PLAN, SHEET GC.02 INSTALL ONE (1) NEW 12" RCP CULVERT WITH CONCRETE END SECTIONS. SEE DETAILS ON SITE GRADING PLAN, SHEET GC.02 EX. 1" POLYETHYLENE SODIUM PERMANGANATE FEED LINE TO REMAIN IN SERVICE. CONVERT TO A RAW WATER SAMPLE LINE SEE DETAIL ON SHEETS CFS.03 AND CFS.07 REMOVE EX. 8" CMP DRAIN LINE INSTALL NEW 3 4 " REINFORCED CLEAR PVC TUBING WITH POLYESTER BRAID SODIUM PERMANGANATE CHEMICAL FEED LINE IN 2" PVC SCH. 80 CONDUIT FROM WTP TO NEW INTAKE PUMP STATION INSTALL NEW 3 4 " REINFORCED CLEAR PVC TUBING WITH POLYESTER BRAID SODIUM PERMANGANATE CHEMICAL FEED LINE IN 2" PVC SCH. 80 CONDUIT FROM WTP TO NEW INTAKE PUMP STATION CUT, CAP, PLUG EX. CHEMICAL FEED LINE SEE ELECTRICAL SITE PLAN FOR REVISON DETAILS EXISTING DRAIN IS NO LONGER IN USE. CONTRACTOR TO REMOVE OR RETIRE IN PLACE AND CUT, CAP, PLUG AS REQUIRED DURING EXCAVATION OF NEW TANKS, DRYING BEDS EXISTING DRAIN TILE CONTRACTOR TO REMOVE OR RETIRE IN PLACE AND CUT, CAP, PLUG AS REQUIRED DURING EXCAVATION OF DRYING BEDS CUT, CAP, PLUG EX. CHEMICAL FEED LINE EX. 1" POLYETHYLENE SODIUM PERMANGANATE FEED LINE TO REMAIN IN SERVICE. CONVERT TO A RAW WATER SAMPLE LINE SEE DETAIL ON SHEETS CFS.03 AND CFS.07 INSTALL NEW 12" FINISHED WATER MAIN. SEE DETAIL ON SHEET C1.02 SEE ELECTRICAL SITE PLAN FOR REVISON DETAILS CONNECT TO EX. 8" CMP DRAIN LINE INSTALL FITTINGS AND INSTALL APPROX. 50 L.F. OF NEW 8" CMP MAINTAIN SLOPE FROM CONNECTION POINT TO OUTLET. OUTLET TO DITCH INSTALL NEW 3 4 " WATER MAIN. SEE DETAILS ON SHEETS C1.01 AND C1.02 INSTALL WET TAP SEE DETAILS ON SHEET C1.02 CONCRETE SIDE DITCH EXISTING MIXED OXIDANT DISINFECTANT AND AMMONIA CHEMICAL FEED LINES TO BE RETIRED IN PLACE INSTALL WET TAP SEE DETAILS ON SHEET C1.02 NOTE: SEE SHEETS E.01 AND E.02 FOR ELECTRICAL SITE PLAN Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2