Midwestern Engineers, Inc. Plan Preview

0 r 0 w z Q r w t.: M - 0 z Q 0 0 0 " N " 0 0 z < w r 0 0 0 w i' w 0 0 0 z ,< �� < � 'O " "l ;; 0 1 Q •O NM ::, � Oo NO -M ..l �8 ;, � =� rn � l!i� 0 .. "w X � o" � •• ,, - 0 "o "' ,o oz ':I: o-, 00 >< 0� c: N ��<• JUNCTION BOX STAINLESS STEEL CABLE ACCESS ALUMINUM • • CONTINUOUS PIANO HINGE FRONT VIEW 14 " RIGHT SIDE LEFT SIDE 8 .. 7 " FACE-MOUNT PADLOCKABLE HASP LOUVER PLATES STAINLESS STEEL --ALUMINUM MESH NOTE, JUNCTION BOX DIMENSIONS SHOWN ARE FOR REFERENCE ONLY, CONTRACTOR TO SIZE FOR APPLICABLE PUMP APPLICATION. PUMP#1 & INSTRUMENTS JUNCTION BOX#1 DETAIL NOT TO SCALE JUNCTION BOX STAINLESS STEEL CABLE ACCESS ALUMINUM • CONTINUOUS PIANO HINGE FRONT VIEW 14 " (APPLICABLE TO BASE BID AND ALT. BID) RIGHT SIDE LEFT SIDE 8 " FACE-MOUNT PADLOCKABLE HASP .. LOUVER PLATES STAINLESS STEEL ALUMINUM MESH NOTE, JUNCTION BOX DIMENSIONS SHOWN ARE FOR REFERENCE ONLY, CONTRACTOR TO SIZE FOR APPLICABLE PUMP APPLICATION. PUMP #2 &#3 JUNCTION BOX#2 DETAIL NOT TO SCALE D RIGID STEEL PVC COATE CONDUIT IN BASE TURN FOR PVC C CONCRETE ED OUT 12" ONNECTION • (APPLICABLE TO BASE BID AND ALT. BID) - 4" SQUARE STRAIGHT STEEL POLE HAND HOLE - - @ TOP ANCHOR BO (TEMPLATE MANUFACTU LTS / 1),'' CLEAR 2" ,-VAULT FOR SPLICING OF LIGHTING TORS. PROVIDE TED SPLICE BY RER) #3 CIRCULA @ 10" O.C R TIES (8)#5 VER EQUALLY S T. BARS PACED . -·" . . . • . . . ' • • . • . . •• . • , . • . • •. . • ', . • 3" I "' " ' z ' :, 0 I ,n CIRCUIT CONDUC WATER TIGHT RA ASSEMBLIES. LOCATE ADJACENT GHT FIXTURES TO PROPOSED LI PULL BOX "A" l ' " ��CONDUIT 3" CLEAR AND BOTTO � SIDES \ . . • ! -CONDUIT & WIRE PER BRANCH S FOR CIRCUITS !f• , 8'-0 CU. CLAD GROUND RO " D . - • ONE LINE DIAGRAM " . � ' ' . � 4,000 PSI 6% AIR ENTRAINED CONCRETE PIER FIXTURE "D" DETAIL (TYP.) NOT TO SCALE (APPLICABLE TO BASE BID AND ALT. BID) GENERAL ELECTRICAL NOTES (APPLICABLE TO BASE BID AND ALTERNATE BID) I. ALL WORK SHALL COMPLY WITH INDIANA ELECTRICAL CODE, CURRENT EDITION. 2. PROVIDE ALUMINUM UNI-STRUT AND ACCESSORIES AS REQUIRED TO MOUNT ELECTRICAL EQUIPMENT. ALL HARDWARE SHALL BE STAINLESS STEEL. 3. ALL CONDUIT SHALL BE SCHEDULE 80 PVC, UNLESS OTHERWISE NOTED. GROUT AROUND ALL PENETRATIONS INTO CONCRETE STRUCTURES. 4. ALL ENCLOSURES SHALL BE NEMA 4X S.S. UNLESS OTHERWISE NOTED. ALL ENCLOSURES SHALL HAVE A HASP AND STAPLE FOR PADLOCK. 5. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONDUIT, WIRING, OTHER MATERIAL, AND INSTALLATION FOR A COMPLETE AND FUNCTIONAL SYSTEM. 6. CONTRACTOR TO LOCATE ALL UNDERGROUND UTILITIES PRIOR TO EXCAVATION. SEED AND STRAW ALL SURFACES TO PRE-DISTURBED CONDITION. 7. CONTRACTOR TO REMOVE UNUSED ELECTRICAL EQUIPMENT AT EXISTING LIFT STATION AS A RESULT OF THE PROJECT. OWNER RESERVES THE RIGHT TO ANY REMOVED EQUIPMENT. ANY UNWANTED EQUIPMENT, MATERIAL, CONDUCTORS, ETC. SHALL BE DISPOSED OF BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 8. ENSURE 5' MIN. BETWEEN WETWELL VENT AND JUNCTION BOXES. LOCATE NEW JUNCTION BOX AT A MIN. OF 18" ABOVE TOP OF WELL. FIELD LOCATE EXACT LOCATION w/ OWNER DURING CONSTRUCTION PRIOR TO INSTALLATION. 9. CONTRACTOR TO VERIFY CONDUIT SIZE BETWEEN JUNCTION BOX AND PUMPS IN WET WELL TO ACCEPT PUMP POWER CABLES (PER NEC), TYPICALLY USE LONG SWEEP ELBOWS. I0. ALL UTILITY FEES WILL BE PAID BY OWNER IN FULL PRIOR TO CONSTRUCTION. CONTRACTOR TO CONTACT GARY FISHERO w/ CRAWFORDSVILLE ELECTRIC LIGHT & POWER AT 765-362-1900 A MIN. OF THREE WEEKS PRIOR TO COORDINATE NEW SERVICE INSTALLATION. NOTIFY OWNER OF ALL REQUIRED OUTAGES A MIN. OF 48 HOURS IN ADVANCE. 11. POWER FOR TEMPORARY BYPASS PUMPING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 12. MAX. HEIGHT TO DISCONNECT HANDLE PER NEC. 13. PULL BOXES SHALL BE SIZED AND QUANTIFIED BY CONTRACTOR PER NEC. PULL BOX SCHEDULE TYPE BOX DESCRIPTION COVER DESCRIPTION DIMENSIONS COLORS " A " UL LISTED UNDERGROUND PULL BOX MADE OF GASKETED w/ 2 BOLTS AND "LIGHTING" LOGO 11 ''Wx1B"Lx12"D GREEN IN POLYMER CONCRETE GASKETED w/ SOLID BOTTOM QUAZITE CAT.# PG-I118-CG-00-29 GRASSY AREAS QUAZITE CAT.# PG-1118-DG-12. CONCRETE COLOR IN SIDEWALKS NOTE, CONTRACTOR TO INSTALL PULL BOXES PER MANUFACTURERS RECOMMENDATIONS. ALL CONDUIT PENETRATIONS SHALL BE SEALED TO PROVIDE WATER TIGHT CONNECTION. STONE BASE FOR DRAINING. INSTALL PER ARTICLE 314 OF CURRENT NEC. I I I I I I � sour, If 8 ivo. PR' "' I M� A-� RY� co NDUIT 'l""i A ! N" ol"'w "' 1 R "° E" PROVIDED BY CELP PROPOSED FIBERGLASS TRANSFORMER VAULT PROVIDED BY CELP, INSTALLED BY CONTRACTOR. TRANSFORMER PROVIDED AND INSTALLED BY CELP. NOTE, CONTRACTOR TO FIELD LOCATE LIGHT LOCATIONS WITH OWNER PRIOR TO INSTALLATION. /s . f/. .J;, LIGHT FIXTURE SCHEDULE Type Manufacturer / Model Mounting Lamps A COLUMBIA LIGHTING - LXEM4-40HL-RFA-EU-SSL SURFACE 47W LED B CURRENT LIGHTING - LNC2-48L-35-4K7-4W-UNV-DBT SURFACE 35W LED C DUAL LITE - EVCURW LED COMBINATION EXIT/EMERGENCY LIGHT SURFACE 1.65W LED D INDUSTRIAL LIGHTING PRODUCTS - SAS-6L-U-40-T4. MOUNT AT 18' POLE 44.2W LED NOTE, CONTRACTOR SHALL PROVIDE ALL REQUIRED MATERIALS, BRACKETS, CABLES, PHOTOCELLS, ETC. FOR FULLY FUNCTIONAL SYSTEM. NOTE, CONTRACTOR TO CONTACT TRAVIS BELDEN WITH ESL SPECTRUM AT (317) 800-8552 FOR LIGHT FIXTURE PRICING PRIOR TO BID. / s . f/ 4? I -0 T. CONC. SLAB w I No. 6 - BARS @ 12" O.C.E.W. PLACED 2" BELOW TOP OF SLAB, OVER MIN. 6" COMPACTED SUB-BASE 1 • '11r1 11 11 · '· . . , . .. . ' 111 = . -. --=11 , •• . . . • • 12"1 WIDTH OF GENERATOR - 30" 30"#5 BARS ' - @ 12" O.C. . • . I ; · . . . · T)M1J I I 1. " • . �1r i,J 1 � I 1 12,, No. 6 ...._ CONT., TYP. GENERATOR PAD DETAIL NOT TO SCALE (APPLICABLE TO BASE BID AND ALT. BID) 0 OVERALL ELECTRICAL SITE PLAN SCALE, I" 0 30' (BASE BID) z < w! WU a..: ..:� w IL o!S ..J "'z ..J �o -< W"" ::E I- >z 1J) � w< 0 > lii "' Q;; lil t � 0::: c' o..:11,1.1wO'£ ::E ::E J: (:I.. :, M5w1- � o ::E > ..: u w�Oo pZ >- I- 0:: U.. IX U'JUQ. W >"' ::E O:; U'J ::c 1-4 0 ..: I!) (:I.. 0 W "" O E-- ;:: J: is w� :>-<:; "' ...I ,.... > "" - ..: > 0 < "' I- C ... ..: zo <"' "' ;:: REVISIONS - .• /(1!-�L I 9/18/24 BID SET �2024 Midwestern Engineers. Inc. 802 Wes1 Broadway Stn."el PO. Box 295 Loogoo1ee. lnctiana 47553 DAT£ JULY 2024 DESIGN A.F.B. DRAWN C.N.M. a.c. CHECK W.A.E. PROJECT NUMBER 2023083-00 11 11 OF FlLE NUMBER 26 44316 I Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2