Midwestern Engineers, Inc. Plan Preview

TO ELECTRICAL BUILDING, SEE ELECTRICAL SITE PLAN FOR CONTINUATION MIN. 24" COVER CONTRACTOR TO PROVIDE AND INSTALL CONDUIT AND WIRING BETWEEN TWO JUNCTION BOXES, PUMP CONTROL PANELS AND PLC CONTROL PANEL EACH w/ CLASS I DIV. I SEAL OFFS, TYP. USE MYERS HUBS. • .. • . . .. • . ,. .. •• . • • ' ' • . ' • • . .. • . • - .. >:.. .. • . . . ' . . . . ,, .. CONTINUOUS HINGED NEMA 4X S.S. VENTED /""llr-., JUNCTION BOX ANCHORED TO CONCRETE LID, BEHIND OPENED WETWELL HATCH. CORE DRILL ENTRY TO WETWELL (TYP.) FOGROD CONTROLLER PROVIDED ---1 AND INSTALLED BY CONTRACTOR j • ' . • • • . . (2) 32.9HP PROPOSED (1) 32.9HP FUTURE 480V-30, 43.9 FLA . .. . •• • • • • ••• • .. ., •• .. •• ' . . • •• LOCATE 60" AWAY FROM JUNCTION BOXES RADAR LEVEL SENSOR PROVIDED AND INSTALLED BY CONT CTOR LIFT STATION ELECTRICAL RISER NOT TO SCALE (BASE BID) NOTE: CONTRACTOR TO FIELD LOCATE LIGHT LOCATIONS WITH OWNER PRIOR TO INSTALLATION. <.... PROPOSED SQ.D 120/208V-3¢, 4W, NQ, 100A PANELBOARD "A", 42 CIRCUIT, TYPE 1 ENCLOSURE IN PROPOSED ELECTRICAL BUILDING, SOLID NEUTRAL, INTEGRAL TVSS 4 6 I I )-20A-1P )-20A-1P I, � HWN (2) #12 T (1) #12 C 1" CONOU (2) #10 THWN U. GND. IT G I SQUARE D LG30 V02 3-POLE LIGHTIN CONTACTOR IN NEMA 1 ENCLOSURE w CONTROL CIRCUIT FUSE FORM F. PROVIDE ONE SPST SWITCH FOR PHOTOCELL BYPASS w/ PHENOLIC TA THAT READS "PHOTOCELL BYPASS" G TIE COORDINATE SENSITIVITY w/ OWNER. SINGLE PHOTO CELL TO CONTROL LIGHT FIXTURE CONTACTOR ' ==POLE ·, PC PHOTOCELL POLE LIGHT CONTROL FIXTURES CIRCUIT (1) #10 CU. GND. 1" CONDUIT POLE 2 _POLE 3 1 =sPARE -SPARE (2) #10 THWN (1) #10 CU. GND. 1" CONDUIT PARTIAL ONE LINE DIAGRAM NOT TO SCALE PRIMARY CONDUIT AND WIRE PROVIDED BY CELP PROPOSED METER BASE PROVIDED BY CELP, INSTALLED ON BUILDING BY CONTRACTOR (BASE BID) PROPOSED PANEL "A" PROPOSED CONDUIT FOR PTS AND CTS PROVIDED BY CELP THEN INSTALLED BY CONTRACTOR. WIRING AND METERING BY CELP. PROPOSED LIGHTING CONTACTOR ..___ PROPOSED AUTOMATIC TRANSFER SWITCH PROPOSED ELECTRICAL BUILDING PROPOSED LIFT STATION PLC CONTROL PANEL / A �'�� . \ . FIVE CONDUITS TO GENSET: ,- ._ �-1-4" 480V-3¢ POWER TO ATS / -1" 120V-1¢ POWER FOR BATTERY CHARGER (A-B) I -1" 208V-1¢ POWER FOR BLOCK HEATER (A-5,7) -1" FOR HARDWIRED CONTROL TO PLC -1" FOR ATS CONTROL w/ WIRING "':::::::-.::,___ ·� ' PROPOSED STANDBY t---. I GENERATOR ON ; --,, CONCRETE PAD ---.; .........__ (2) #10 THWN ..___ � 1) #10 CU. GND. / ..___ 1" co ,. N ,. D "' U "' IT___. ; ,, / "' ,-----� .. · ..___ PROPOSED oe--.,:_ , / ACCESS DRIVE --- or NOTE: CONDUITS SHOWN FOR CLARITY AND NOT �'°"."''_,m LIFT STATION ENLARGED ELECTRICAL SITE PLAN SCALE: 1" � 5' (BASE BID) FOUR CONDUITS TO LIFT STATION: -2" PUMP #1 480V-3¢ FROM C.P. TO J.B. #1 -1" PUMP #1 CONTROL FROM PLC PANEL TO J.B. #1 (SEAL FAIL & DVERTEMP) -1" ANALOG CONTROL (RADAR) FROM PLC PANEL TO J.B. #1 -1" DIGITAL CONTROL (FOGROD) FROM PLC PANEL TO J.B. #1 THREE CONDUITS TO LIFT STATION: -2" PUMP #2 480V-3¢ FROM C.P. TO J.B. #2 / / I "' / / -1" PUMP #2 & #3 CONTROL FROM PLC PANEL TO J.B. #2 (SEAL FAIL AND OVERTEMP) -2" PUMP #3 480V-3¢ FROM C.P. TO J.B. #2 (CONDUIT ONLY FOR FUTURE PUMP) � .._ REVISIONS ��� 9/18/24 BID SET C, 2024 Midwestern Engineers, Im:. 802 We�l Broadway Strc<'t P.O. Ilo� 295 loogoo1�. lndiam, 47553 DATE JULY 2024 DESIGN A.F.B. DRAWN C.N.M Q.C. CHECK W.A.E PROJECT NUMBER 2023083-00 1 2 12 OF 26 I FlLE NUMBER I 44315 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2