Midwestern Engineers, Inc. Plan Preview

0 < u u w w z 0 � � - 0 z u 0 0 ,, z w 0 z 0 � w � " 00 w I I t' w' " <) 0 0 � � •" c� Q O U st I NO ,9 NM oo NO -M . �g - ., ww ,. ' • >- •w - C o" "' ·c "• ".o >U oz o-, 00 ,< u� c: N �� <c PANEL 400 AMPERES MCB MAIN CONNECTION ERQEO SED El ECIBIC/ll Bill! DING LOCATION MDPA 480 VOLTS . "IWIRE "I PHASE 65 KAIC SURE/\CE MOUN TING S.EL CIRCUIT WIRE CU. AMPS WI RE ITEM FEED CIRCUIT NO. ITEM FEED SIZE AMPS POLE BUS POLE SIZE NO. 1 PUMP #1 CONTROL PANEL 6 110 3 A 3 110 6 PUMP #2 CONTROL PANEL B C 3 PUMP #3 CONTROL PANEL 6 110 3 A 3 45 8 30 KVA TRANSFORMER B C 5 SPACE 3 A 3 SPACE B C 7 SPACE 3 A 3 SPACE B C TYPED AND LAMINATED PANEL SCHEDULES SHALL BE APPLIED AT COMPLETION OF PROJECT. 0 CD 0 (3) #6 THWN (1) #6 CU. GND. 2" CONDUIT (4) #3 THWN (1) #8 CU. GND. 2" CONDUIT (3) #8 THWN (1) #10 CU. GND. 1" CONDUIT LEGEND VFD CONTROL PANEL, SEE SPECIFICATIONS 30KVA TRANSFORMER, 480V-30, 3W 6 PRIMARY TO 120/208V-30, 4W Y SECONDARY, COPPER WINDINGS, NEMA 1 ENCLOSURE PRIMARY CONDUIT AND WIRE BY-------1 CRAWFORDSVILLE ELECTRIC PROPOSED 277/480V-30, 4W ELECTRIC SERVICE BY CRAWFORDSVILLE ELECTRIC LIGHT & POWER LIGHT & POWER (CELP). PROPOSED FIBERGLASS TRANSFORMER--,+ �- -1-----UIM J---NEW METER BASE PROVIDED BY CRAWFORDSVILLE VAULT PROVIDED BY CELP, INSTALLED ELECTRIC LIGHT & POWER THEN INSTALLED ON BUILDING BY CONTRACTOR. TRANSFORMER BY CONTRACTOR. METERING AND WIRING BY CELP. PROVIDED ANO INSTALLED BY CELP. CONTRACTOR TO PROVIDE AND -:::;------ ;f;____ INSTALL 4" SCH. 80 PVC CONDUIT (4) #600 MCM THWN BY CONTRACTOR w/ 36" COVER ANO WARNING TAPE AT 18" DEEP, PULL ROPE, LONG SWEEP ELBOWS, WIRE AND TERMINATIONS. PROPOSED 400A-3P SERVICE ENTRANCE RATED, DELAYED TRANSITION AUTOMATIC TRANSFER SWITCH IN NEMA 4X S.S. ENCLOSURE )-400A-3P EXOTHERMICALLY WELD #1/0 cu. � IN 1" CONDUIT TO -)\"0,10· CU. CLAD GND. ROD (TYP. OF 3 ON 200A-3P >----PROPOSED 125KW STANDBY GENERATOR, ---m,W�f-. A � SEE SPECIFICATIONS FOR MORE l � INFORMATION. 10' TRIANGULAR SPACING) NOTE, (4) #4/0 THWN, (1) #6 CU. GND., 4" CONDUIT (3) #600 MCM THWN------� PROPOSED SQ.D I-LINE 480V-30, 3W. 400A MCB PANELBOARD "MOPA". 63" (1) #3 CU. GND. MOUNTING SPACE, TYPE 1 ENCLOSURE IN PROPOSED ELECTRICAL BUILDING, 4" CONDUIT SOLID NEUTRAL INTEGRAL SPD POWER METER PM5563 8ACKFED MAIN. 400A-3P A-�--,----�2 ,__ ____3 ,__ _____, 4 --� )--110A-3P )--110A-3P )-110A-3P )-45A-3P IF ALTERNATE BID 40HP, 54.7FLA, 1750 RPM PUMP IS ACCEPTED THE CONTRACTOR SHALL ENSURE THE WIRE SIZE, OVERCURRENT PROTECTION AND VFD IS SELECTED FOR THE MOTOR. ) CD CONTRACTOR TO PROVIDE, SIZE AND INSTALL---1 NEW JUNCTION BOXES. THE JUNCTION BOXES SHOULD INCLUDE ALUMINUM UNISTRUT SUPPORT MOUNTS, VENT, NEMA 4X S.S. ENCLOSURE AND POWER DISTRIBUTION BLOCK. SEE SPECIFICATIONS FOR MORE INFORMATION. M 48DV-30 40 FLA PUMP #1 ) CD (i) JUNCTION BOX M 48DV-30 40 FLA PUMP #2 '.33� L=",. 48DV-30 40 FLA PUMP #3 (FUTURE) 0 30KVA LIGHTING PANEL 100A MCB 30 CKT 12D/208V-30 4W NQ PANELBOARO PROPOSED ONE LINE DIAGRAM NOT TO SCALE 2 4 6 8 I ' _J PANEL A CIRCUIT NO. 1 LIGHTS 100 AMPERES 120/208 VOLTS ' 4WIRE ITEM FEED MCB MAIN CONNECTION WIRE SIZE 12 'PHASE 1n KAIC AMPS 20 POLE 1 CU. BUS A POLE 1 ERQEQSED SIIRE/\CE MOUNTING S.E.L. WIRE AMPS SIZE E l ECIRIC/\1 BIii!DING LOCATION CIRCUIT ITEM FEED NO. 20 12 RECEPTACLES 2 3 LIFT STATION PLC CONTROL PANEL 12 20 1 B 1 20 12 PHOTOCELL 4 5 7 9 11 13 15 17 19 21 23 25 27 29 GENERATOR BLOCK HEATER 12 20 2 C 1 20 10 POLE LIGHTS A 1 20 12 GENERATOR BATIERY CHARGER EXHAUST FAN AND LOUVER 12 20 1 B 1 20 12 MAG METER SPARE 12 20 1 C 2 15 12 DUCTLESS MINI SPLIT SPARE 12 20 1 A SPARE 12 20 1 B 1 20 12 SPARE SPARE 12 20 1 C 1 20 12 SPARE SPARE 12 20 1 A 1 20 12 SPARE SPACE B SPACE SPACE C SPACE SPACE A SPACE SPACE B SPACE SPACE C SPACE TYPED ANO LAMINATED PANEL SCHEDULES SHALL BE APPLIED AT COMPLETION OF PROJECT. MECHANICAL SCHEDULE AH-1 - TRANE ND<WPHD9B112AA MAX. COOLING 12,000 BTUH MAX. HEATING 18,DDD BTUH 29.8 SEER, 16.1 EER DELUXE WIRED REMOTE TAR-4DMAAUU 15' LINESET MLS143812T-15 POWERED BY OUTDOOR UNIT CU-1 - TRANE NTXSPBD9B112AA COOLING CFM 1141 HEATING CFM 1183 MCA 1DA 208V-10 24" SINGLE FAN STAND QSMS2401M I, ,- ,, . - - - . - - .. - �I'< ,_ ,- . ,_ . OUTDOOR UNIT NSION TO \ GER THAN TPRINT SLAB DIME BE 6" LON EACH WAY STAND FOO - MANUFACTURER FURNISHED 24" STAND. RE TO CONCRETE w/ ANCHOR SECU SLAB BOLTS AT EACH FOOT GRADE I . . 6 T C ONCRETE SLAB, 4,000 PSI w/ #3 BARS @ 12" O.C.EW ., AIR ENTRAINED 6% . 5" SLUMP OVER 5 " CRUSHED STONE BASE CONDENSING UNIT DETAIL NOT TO SCALE 6 8 10 12 14 16 18 20 22 24 26 28 30 PROPOSED 120/2D8V 30 4W PROPOSED 480V 30 3W PROPOSED 400A 3P SERVICE c, - ' ' - ' ' _, - SQ.0 NQ, 1ODA PANEL "A" I 400A PANELBOARD . , MDPA" ENTRANCE RATED, DELAYED TRANSITION f-- PROPOSED 3DKVA TRANSFORMER ON 4" CONCRETE HOUSEKEEPING PAD AUTOMATIC TRANSFER SWITCH ' CONTROL WIRING IN CONDUIT '--( ! FL IN M OW METER CABLING CONDUIT TO FLOW ETER TO PLC CONTROL PANEL PER 1/0 LIST � REMOTE FLOW METER ANSMITIER TR PROPOSED NOTE, CONTRACTOR TO FIELD LIGHTING EQUIPMENT TO MAINTAIN NEC CONTACTOR LOCATE CLEARANCE C-- E CONDUIT AND WIRE J TO POLE LIGHTS PROPOSED 4" CONCRETE HOUSEKEEPING PAD CONTROL WIRING IN CONTROL WIRING IN CONDUIT TO PLC CONTROL CONDUIT TO PLC CONTROL PANEL PER 1/0 LIST PANEL PER 1/0 LIST , , <11 PUMP #3 @ PUMP #2 CONTROL PANEL CONTROL PANEL CONTROL WIRING IN CONDUIT TO PLC CONTROL '... PANEL PER 1/0 LIST -@ C, C: 0 :'1 z � en "'� CONTROL WIRING IN ;2 � CONDUIT TO PLC CONTROL -u 0,,_z PANEL PER 1/0 LIST z -u '"r , r c, @ PUMP #1 CONTROL PANEL A-12,14 30A-2P LOCAL DISCONNECT· ----1/,j IN NEMA 3R ENCLOSURE CU-1 SCADA SYSTEM NOTES 1. CONTRACTOR SHALL UTILIZE OWNERS EXISTING CONTROL SYSTEM INTEGRATOR BY CONTACTING NATHEN BURKHART OF TORIC 2. ENGINEERING AT (317) 718-1800 FOR PRICING PRIOR TO BID. A. ALLEN BRADLEY COMPACTLOGIX PLC 8. TYPE 12 PAINTED STEEL ENCLOSURE, WALL MOUNT C. TVSS D. MAPLE SYSTEMS TOUCHSCREEN, 12" E. NETWORK SWITCH, UNMANAGED F. POWER SUPPLY, 24VDC I. INTRINSICALLY SAFE BARRIERS J. OMNISITE ALARM DIALER (EXISTING) K. MISC. DEVICES REQUIRED TO MAKE COMPLETE WORKING SYSTEM G. VEGA WL61 RADAR LEVEL TRANSMITIER FOR PRIMARY CONTROL H. FOGROD LEVEL STICK FOR BACKUP CONTROL DIGITAL INPUTS RTU POWER FAIL SITE POWER FAIL AUTOMATIC TRANSFER SWITCH POSITION - NORMAL/EMERGENCY AUTOMATIC TRANSFER SWITCH - NORMAL SOURCE AVAILABLE GENERATOR RUN STATUS - RUNNING GENERATOR RUN STATUS - FAIL GENERATOR RUN STATUS - ALARM GENERATOR RUN STATUS - LOW FUEL PUMP 1 CONTROL IN VFD PUMP 1 CONTROL IN BYPASS PUMP CONTROL IN HAND PUMP CONTROL IN AUTO PUMP RUN STATUS - VFD RUNNING PUMP RUN STATUS - VFD ALARM PUMP RUN STATUS - BYPASS CONTACTOR RUNNING PUMP 1 RUN STATUS - BYPASS CONTACTOR ALARM PUMP 1 SEAL FAIL PUMP 1 OVERTEMP PUMP 2 CONTROL IN VFD PUMP 2 CONTROL IN BYPASS PUMP 2 CONTROL IN HAND PUMP 2 CONTROL IN AUTO PUMP 2 RUN STATUS - VFD RUNNING PUMP 2 RUN STATUS - VFD ALARM PUMP 2 RUN STATUS - BYPASS CONTACTOR RUNNING PUMP 2 RUN STATUS - BYPASS CONTACTOR ALARM PUMP 2 SEAL FAIL PUMP 2 OVERTEMP PUMP 3 CONTROL IN VFD PUMP 3 CONTROL IN BYPASS PUMP 3 CONTROL IN HAND PUMP 3 CONTROL IN AUTO PUMP 3 RUN STATUS - VFD RUNNING PUMP 3 RUN STATUS - VFD ALARM PUMP 3 RUN STATUS - BYPASS CONTACTOR RUNNING PUMP 3 RUN STATUS - BYPASS CONTACTOR ALARM PUMP 3 SEAL FAIL PUMP 3 OVERTEMP STATION HIGH LEVEL BACKUP CONTROL RESET TOTALIZED FLOW PULSE DIGITAL OUTPUTS PUMP 1 RUN COMMAND PUMP 2 RUN COMMAND PUMP 3 RUN COMMAND COMMON ALARM ANALOG INPUTS PUMP 1 VFD SPEED REFERENCE PUMP 2 VFO SPEED REFERENCE PUMP 3 VFD SPEED REFERENCE STATION LEVEL BUILDING TEMPERATURE INSTANTANEOUS FLOW ANALOG OUTPUTS PUMP 1 VFD PACING SIGNAL PUMP 2 VFD PACING SIGNAL PUMP 3 VFD PACING SIGNAL STATION PLC CONTROL PANEL AUTOMATIC TRANSFER SWITCH AUTOMATIC TRANSFER SWITCH AUTOMATIC TRANSFER SWITCH STANDBY GENERATOR STANDBY GENERATOR STANDBY GENERATOR STANDBY GENERATOR PUMP - VFD/STARTER CONTROL PANEL PUMP - VFD/STARTER CONTROL PANEL PUMP - VFD/STARTER CONTROL PANEL PUMP - VFD/STARTER CONTROL PANEL PUMP - VFO/STARTER CONTROL PANEL PUMP - VFD/STARTER CONTROL PANEL PUMP - VFO/STARTER CONTROL PANEL PUMP 1 - VFD/STARTER CONTROL PANEL STATION PLC CONTROL PANEL STATION PLC CONTROL PANEL PUMP 2 - VFO/STARTER CONTROL PANEL PUMP 2 - VFD/STARTER CONTROL PANEL PUMP 2 - VFD/STARTER CONTROL PANEL PUMP 2 - VFD/STARTER CONTROL PANEL PUMP 2 - VFD/STARTER CONTROL PANEL PUMP 2 - VFD/STARTER CONTROL PANEL PUMP 2 - VFD/STARTER CONTROL PANEL PUMP 2 - VFO/STARTER CONTROL PANEL STATION PLC CONTROL PANEL STATION PLC CONTROL PANEL FUTURE FUTURE FUTURE FUTURE FUTURE FUTURE FUTURE FUTURE FUTURE FUTURE FOGROD CONTROLLER VIA WETWELL JUNCTION BOX #1 LOCAL PUSHBUTION FLOW METER TRANSMITIER PUMP 1 - VFD/STARTER CONTROL PANEL PUMP 2 - VFD/STARTER CONTROL PANEL FUTURE OMNISITE PUMP 1 - VFD/STARTER CONTROL PANEL PUMP 2 - VFD/STARTER CONTROL PANEL FUTURE RADAR LEVEL SENSOR VIA WETWELL JUNCTION BOX #1 AMBIENT TEMPERATURE SENSOR FLOW METER TRANSMITIER PUMP 1 - VFO/STARTER CONTROL PANEL PUMP 2 - VFD/STARTER CONTROL PANEL FUTURE 3. SEPARATE ALL POWER AND CONTROL, DIGITAL, ANALOG, ETHERNET AND FIBER INTO DEDICATED CONDUITS. MINIMUM COVER SHALL BE 24" w/ WARNING TAPE AT 12" UNLESS OTHERWISE REQUIRED BY NEC. 4. IF ALTERNATE BID IS ACCEPTED, THE ABOVE MENTIONED POWER DISTRIBUTION ANO CONTROLS EQUIPMENT SHALL BE COMBINED AND HOUSED IN A NEMA 4X S.S. ENCLOSURE. SEE ALTERNATE BID SHEET AND ELECTRICAL SPECIFICATIONS FOR MORE INFORMATION. A-6 A-2 PROPOSED 12D/208V-30, 4W, SQ.D NQ, 100A PANEL "A" PROPOSED MDPA-8,10,12 LIGHTING CONTACTOR "A" AH-1 MDPA-3 PUMP #3 CONTROL PANEL PROPOSED 480V-30, 3W, 400A PANELBOARD "MDPA. , PROPOSED 30KVA PROPOSED 400A-3P PROPOSED METER BASE PROVIDED BY CELP, INSTALLED ON BUILDING BY CONTRACTOR E ----/. TO PROPOSED TRANSFORMER, SEE SITE PLAN FOR CONTINUATION E A-2 1-!fl--l TO PROPOSED TRANSFORMER, SEE ONE LINE DIAGRAM TRANSFORMER ON SERVICE ENTRANCE RATED, 4" CONCRETE DELAYED TRANSITION REMOTE HOUSEKEEPING PAD AUTOMATIC TRANSFER SWITCH FLOW METER A-10 TRANSMITIER A-1 © "C" A-3 A-1 C, C: 0 :'1 "A" "A" �en "' �0,, r =' -u 0 ,,_z MDPA-2 MOPA-1 z -u c,; r r c, PUMP #2 PUMP #1 CONTROL PANEL CONTROL PANEL (FUTURE) PROPOSED 4•· CONCRETE--- +tt-t---1 HOUSEKEEPING PAD (FUTURE) 0 ELECTRICAL BUILDING CONTROL SCALE, J<;" = 1'-o·· (BASE BID) CONDUIT ONLY- - - -�-1 TO LIFT STATION 0 1-----------+�--CONDUIT AND WIRE TO LIFT STATION ELECTRICAL BUILDING POWER SCALE, J<;" = 1'-0" (BASE BID) • u Q - RE.VlSIONS /(£-� 9/18/24 BID SET C2024 Midwe.stem Engint'ers. In(:. 302 Wesl Bro�dway Street P 0. Box �95 Loogool�-.:. lndiana 4755} DATE JULY 2024 DESIGN A.F.B. DRAWN C.N.M. a.c. CHECK W.A.E. PROJECT NUMBER 2023083-00 13 13 OF 26 I FlLE NUMBER 44314 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2