Midwestern Engineers, Inc. Plan Preview

24" LENGTH OF STAND x 4' DEEP -, . . '• .; . .. . -�. ·� � • ,• '1 . '• . . '. .. : �· ,•, '; __ ... . . -: . . ...� ,: . . i · .. t " . •' .. . (' . ··� .. ' .:, .... �. ... .. � .. . .. :·... : ... • • • • ;-•.! • •. • .. ,,.> ALUMINUM ANGLE WELDED TO ALUMINUM BASE PLATE (4) )," STAINLESS STEEL ALL-THREADS IN CONCRETE 4 H x4"�" ALUM. ANGLE GENERATOR CONTROL TO CONTROL PANEL PER 1/0 LIST \ PROPOSED 125KW STANDBY GENERATOR SEE SPECIFICATIONS FOR MORE INFORMATION . :- ; :· -� './ · . . . . . · �h ..� • . .. ·.'_. •.......• ': . .. � '· :· .. ' ' ' . .. '' ... -� -·· . ' . . )," ALUM. BASE PLATE :- ·'·:. ·: .:· : ... ;. -� );· .�. .. ':. • 0 •. • • r . . . ..· .... ,. • /.- ., :_,. •.·- ••• J •.. . ·• . . � .. '·. ' .. ·. ! • ' .t •., t, •. ' �A-5,7�A-8 BASE DETAIL A NOT TO SCALE I . • •• • • • 4 • .. • • • • • • • . . • ' ' • 4 : • . -CONCRETE GENERATOR PAD, SEE DETAIL NOTE, CONDUITS SHOWN FOR REFERENCE ONLY, NOT NECESSARILY INTENDED TO SHOW EXACT QUANTITY OR LOCATION ® (3) #6 THWN (1) #6 CU. GND. 2" CONDUIT LEGEND CONTRACTOR TO PROVIDE, SIZE AND INSTALL NEW JUNCTION BOXES. THE JUNCTION BOXES SHOULD INCLUDE ALUMINUM UNISTRUT SUPPORT MOUNTS, VENT, NEMA 4X S.S. ENCLOSURE AND POWER DISTRIBUTION BLOCK. SEE SPECIFICATIONS FOR MORE INFORMATION. PRIMARY CONDUIT AND WIRE BY------1 CRAWFORDSVILLE ELECTRIC �+�., LIGHT & POWER (CELP). PROPOSED 277/480V-3¢, 4W ELECTRIC SERVICE BY CRAWFORDSVILLE ELECTRIC LIGHT & POWER PROPOSED FIBERGLASS TRANSFORMER VAULT PROVIDED BY CELP, INSTALLED BY CONTRACTOR. TRANSFORMER PROVIDED AND INSTALLED BY CELP. CONTRACTOR TO PROVIDE AND ---- -•.r, INSTALL (4) #600 MCM THWN IN 4" SCH. 80 PVC CONDUIT w/ 36" COVER AND WARNING TAPE AT 18" DEEP, PULL ROPE, LONG SWEEP 1-- -NEW METER BASE PROVIDED BY CRAWFORDSVILLE ELECTRIC LIGHT & POWER THEN INSTALLED ON BUILDING BY CONTRACTOR. METERING AND WIRING BY CELP. PROPOSED 400A-3P SERVICE ENTRANCE RATED, DELAYED TRANSITION AUTOMATIC TRANSFER SWITCH IN NEMA 4X S.S. ENCLOSURE }400A-3P 200A-3P ELBOWS, WIRE AND TERMINATIONS. EXOTHERMICALLY WELD #1/0 cu. � IN 1" CONDUIT TO -X."otix1a· cu. CLAD GND. ROD (TYP. OF 3 ON 10' TRIANGULAR SPACING) '---@ f----PROPOSED 125KW STANDBY GENERATOR, ----MW',;-J-" G � SEE SPECIFICATIONS l(4) #4/0 THWN, (1) #6 CU. GND., 4" CONDUIT (3) #600 MCM THWN-----'Y (1) #3 CU. GND. 4" CONDUIT PROPOSED PUMP CONTROL PANEL, 400A, 480V-3¢ IN NEMA 4X S.S. ENCLOSURE PROVIDED AND INSTALLED BY CONTRACTOR. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. NOTE, IF ALTERNATE BID 40HP, 54.7FLA, 1750 RPM PUMP IS ACCEPTED THE CONTRACTOR SHALL ENSURE THE WIRE SIZE, OVERCURRENT PROTECTION AND VFD IS SELECTED FOR THE MOTOR. 40 ,:: 3P 2 3 4 5 �· ---.I,___..I__I_________ I---r ------I } }110A-3P }110A-3P }11OA-3P } }20A-2P NEMA SIZE 3 ® J.B. ® JUNCTION BOX SUBMERSIBLE CABLING----< SUPPLIED BY PUMP MANUFACTURER THEN INSTALLED BY CONTRACTOR (TYP.) 33HP PUMP #1 480V-3¢ 40 FLA 33HP PUMP #2 48DV-3¢ 40 FLA 33HP PUMP #3 480V-3¢ 40 FLA (FUTURE) NEMA SIZE 3 PANEL A/C 480V-3¢ 1OKVA CONTROL TRANSFORMER 480V-1¢ PRl.- 120/240V-1¢ SEC. PROPOSED ONE LINE DIAGRAM NOT TO SCALE (ALTERNATE BID) PANEL "A" 40A 120/240V- 1¢, 3W • . • . • • • PROPOSED 400A-3P SERVICE ENTRANCE RATED, DELAYEDTRANSITION AUTOMATIC TRANSFER SWITCH IN NEMA 4X S.S. ENCLOSURE NEW METER BASE PROVIDED--+-+< (';;\ BY CRAWFORDSVILLE ELECTRIC � LIGHT & POWER THEN INSTALLED BY CONTRACTOR 4" ALUMINUM ANGLE---, ATS CONTROL PER 1/0 LIST � A/C LIFr STATION PUIIP CONTROL PANEL NKIIA 4X S.S. rCONTRACTOR TO PROVIDE AND INSTALL CONDUITS AND WIRING BETWEEN TWO JUNCTION BOXES AND PUMP CONTROL PANEL EACH w/ CLASS I DIV. I SEAL OFFS, TYP. USE MYERS HUBS. SEE SITE LOCATE 60" AWAY FROM- PLAN FOR ADDITIONAL INFORMATION. JUNCTION BOXES CONTINUOUS HINGED NEMA 4X S.S. VENTED JUNCTION BOX ANCHORED TO CONCRETE LID. ALUMINUM UNI-STRUT---ia::lj�� TO TRANSFORMER, SEE SITE-=--rt-1 PLAN FOR CONTINUATION --­ · 5,�CTIO, :=:!; BOX SEE DETAIL THIS SHT. l \ · "' = === · _, Jd, • " . . . . . . SEE BASE DETAIL THIS SHEET '- '- 480V-3¢ • \ L .....,,, -'-4 . i-:;:�'-""-41--�\----11--F''f.-, • \ L � "" . -. .-. ---��----�, .---. �. �-. ����----'-�.� "' . : . . • " . . . .. . • . " . . • ··,. _.1-- -,� 36" COVER w/ WARNING TAPE @ 12" . ' • " . . • • •• • .. • • " � • • • • • • 4 ·". • • • , • •• � , ,r � ·• �" •. " . .. � � , . . ,\ .. . . ·. . "' . - .. . .. � �­ • • • • . . . • � f • • • 4 ... • . 'c'=====:==*c,c· ==· ==,==·=�c:J · . .. . . ". . . . . .. . • • .. • • • .. . ' . . • • , . . . " . • • • • •• •• • • " . . .. . 4 • .. • . . • • �- �. =====;=====:=== .. . . . .. • • •· • • . ... . ··" . . . " . ,,..,,- coRE DRILL ENTRY TO WETWELL / (TYP.) . " RADAR LEVEL SENSOR PROVIDED AND INSTALLED BY CONTRACTOR 11 - " -(4) #4/0 THWN (1) #6 CU. GND. -EXOTHERMICALLY WELD #1/0 CU. IN 1" CONDUIT TO Y,"¢,1O' CU. CLAD GND. ROD (TYP. OF 3 ON 10' TRIANGULAR SPACING) -REINFORCED 3'x12'x3' CONCRETE SLAB w/ #6 BARS @ 8" O . C.E.S.T.B. AND #5 TIES @ 16" O.C. .. • FOGROD CONTROLLER PROVIDED- - AND INSTALLED BY CONTRACTOR 4" CONDUIT TO GENERATOR PROPOSED LIFT STATION RISER - ALTERNATE BID NOT TO SCALE PROPOSED SQ.D 120/240V-1¢, 3W, 40A PANELBOARD "A", 30 CIRCUIT, TYPE 1 ENCLOSURE IN PROPOSED LIFT STATION CONTROL PANEL, SOLID NEUTRAL, INTEGRAL TVSS --.... 4 6 <..... HWN (2) #12 T (1) #12 C 1" CONDU U. IT G I SQUARE D LG30 V02 3-POLE LIGHTIN CONTACTOR IN NEMA 1 ENCLOSURE w CONTROL CIRCUIT FUSE FORM F. PROVIDE ONE SPST SWITCH FOR PHOTOCELL BYPASS w/ PHENOLIC TA THAT READS "PHOTOCELL BYPASS" G TIE GND. j}20A-1P j}20A-1P ' (2) #10 THWN ' (1) #10 CU. GND. 1" CONDUIT ==POLE 1 _POLE 2 _POLE 3 -SPARE -SPARE (2) #10 THWN ' ' (1) #10 CU. GND. PC ;:\ 1" CONDUIT PANEL A CIRCUIT NO. 1 LIGHTS an AMPERES 120/240 VOLTS ' 'WIRE ITEM FEED 3 LIFT STATION PLC CONTROL PANEL ....L GENERATOR BLOCK HEATER 7 9 SPARE 11 SPARE 13 SPARE 15 SPARE 17 SPARE 19 SPARE 21 SPACE 23 SPACE 25 SPACE 27 SPACE 29 SPACE MCBMAIN CONNECTION WIRE SIZE 12 12 12 12 12 12 12 12 12 1 PHASE rn KAIC AMPS 20 20 20 20 20 20 20 20 20 POLE 1 1 2 1 1 1 1 1 1 CU. BUS A B A B A B A B A B A B A B A . • ,. " . . " • • . •• • ·' • • •. • . • • 4 • .. • I/ .. • / . .. . . . . . . .. .. • • • 'd • ... (2) 32.9HP PROPOSED (1) 32.9HP FUTURE 480V-3¢, 43.9 FLA ••• • 1 IFT STA IIQ� CQ�I8QI EA�EI E�CI QSUBE LOCATION POLE 1 1 1 1 1 1 1 1 1 1 SLJ8FACE MOUNTING S.E.L. WIRE AMPS SIZE 20 12 RECEPTACLES 20 12 PHOTOCELL 20 10 POLE LIGHTS ITEM FEED 20 12 GENERATOR BATIERY CHARGER 20 12 MAG METER 20 12 SPARE 20 12 SPARE 20 12 SPARE 20 12 SPARE 20 12 SPARE SPACE SPACE SPACE SPACE SPACE CIRCUIT NO. 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 COORDINATE SENSITIVITY w/ OWNER. SINGLE PHOTO CELL TO CONTROL LIGHT FIXTURE CONTACTOR PHOTOCELL CONTROL CIRCUIT POLE LIGHT FIXTURES 1-2 TYPED AND LAMINATED PANEL SCHEDULES SHALL BE APPLIED AT COMPLETION OF PROJECT. PARTIAL ONE LINE DIAGRAM NOT TO SCALE .• . . •• . . . :,: .. • •. ., .. . • • . . • • • • . . • • • ' . • • • • • • \ z < w� WU a = .. � lil ... ell "' 1-z ..-1 zo -< w � :;: I- >z w� w< 0 � Iii"' Ci 1:: I-I- r:i::: " °'"-Z Q['.: a..:iww z :::.: :::;::Cµ.,:, >-1-'w'""' � o :::;:O>a: u w�Oo � >- t;; u &: u. &3 >- "' :::.: u:. u, ::c I-! 0 a:c, µ., O w � o f- :!: :c 15 w� �:E "'_, b >-� - "'� u <c = = zo <"- "' 3: REVISIONS #� 9/18/24 BID SET Cl 2024 Midwe.11em Engine-er;. Inc. 802 Wei;t 8ro3dw,1y Street ?.O. Box 2')5 Loogoolce. lndian" 47553 DATE JULY 2024 DESIGN A.F.B. DRAWN C.N.M. Q.C. CHECK W.A.E. PROJECT NUMBER 2023083-00 15 15 OF 26 I Fll£ NUMBER 44312 I Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2