Midwestern Engineers, Inc. Plan Preview
EXISTING ALUM ROOM EXISTING SODIUM PERMANGANATE ROOM EX. FLOCCULATORS EX. TUBE SETTLER CLARIFIERS - #1 NPW NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 AL AL AL AL AL AL NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 AL AL AL AL AL AL CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW STATE OF N 19800122 J O H N W . W E T Z E L P R O F E S S I O N A L E N G I N E E R R E G I S T E R E D I N D I A N A o P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern 2019 9/18/19 BID SET Author: KGAINES, Plot Date: 10/4/2019 9:26 AM Path: Z:\CAD_INCOMPLETE\2018022-00_CITY OF HUNTINGBURG_WS_DISTRIBUTION SYSTEM IMPROVEMENTS AND PLANT UPGRADES\025_PRODUCTIONDWG_DIV 2\12 - MASTER MECHANICAL PLANS.DWG WATER SYSTEM IMPROVEMENTS DIV. II - WATER TREATMENT PLANT IMPROVEMENTS FOR THE CITY OF HUNTINGBURG DUBOIS COUNTY, INDIANA EXISTING CHEMICAL FEED SYSTEMS FLOOR PLAN DEMOLITION SCALE: 1/2" = 1'-0" CFS.03 44 39486 EYE WASH (TO REMAIN) SODIUM PERMANGANATE MIXER PANEL SODIUM PERMANGANATE METERING PUMP CONTROL PANEL NOTE: · ALL CHEMICAL FEED LINES, EQUIPMENT, AND OTHER APPURTENANCES SHOWN WITH RED CROSS HATCH TO BE REMOVED AND DISPOSED OF IN ACCORDANCE TO LOCAL, STATE AND FEDERAL REGULATIONS. · THE OWNER HAS RIGHTS TO ALL DEMOLISHED MATERIALS. CONTRACTOR TO COORDINATE SALVAGED ITEMS WITH OWNER PRIOR TO ANY DEMOLITION WORK. SALVAGED ITEMS SHALL BE STORED ON SITE AS DIRECTED BY OWNER. CONTRACTOR SHALL REPLACE EXISTING 4" GATE VALVE ON DRAIN LINE CONVERT EX. CHEMICAL FEED LINE TO RAW WATER SAMPLING LINE SEE SHEET CFS.07 FOR MORE INFORMATION EXISTING SODIUM PERMANGANATE STORAGE TANKS, METERING PUMPS AND ASSOCIATED APPURTENANCES TO BE REMOVED. THE NEW SODIUM PERMANGANATE FEED SYSTEM SHALL BE OPERATIONAL PRIOR TO REMOVAL/RETIREMENT OF THE EXISTING SYSTEM EXISTING ALUM STORAGE TANKS, METERING PUMPS AND ASSOCIATED APPURTENANCES TO BE REMOVED. THE NEW ALUM FEED SYSTEM SHALL BE OPERATIONAL PRIOR TO REMOVAL/RETIREMENT OF THE EXISTING SYSTEM EXISTING BRINE TANK TO BE REPLACED CHEMICAL FEED PIPING LEGEND ALUM CARBON MIXED OXIDANT DISINFECTANT SOLUTION FLUORIDE NON-POTABLE WATER SODIUM PERMANGANATE MISC. CHEMICAL PIPING AL CARBON CS F NPW NaMn04 EX. ALUM STORAGE TANK EX. ALUM STORAGE TANK EX. ALUM STORAGE TANK EX. ALUM STORAGE TANK EX. SODIUM PERMANGANATE EX. SODIUM PERMANGANATE STORAGE TANK EX. BRINE TANK EX. SODIUM PERMANGANATE METERING PUMPS EX. ALUM METERING PUMPS (FUTURE SALT STORAGE ROOM) (FUTURE SALT STORAGE ROOM/MIXED OXIDANT SYSTEM ROOM) EX. ALUM ROOM EX. SODIUM PERMANGANATE ROOM PLAN SHEET CFS.03 LOCATION 1st FLOOR BUILDING FLOOR PLAN EXISTING ALUM FEED LINE WILL BE REUSED FROM THIS POINT TO THE INJECTION POINT NOTE: ALL POWER OR CONTROL WIRING ASSOCIATED WITH CHEMICAL FEED SYSTEMS OR EQUIPMENT BEING DEMOLISHED WITHIN THE SCOPE OF THIS PROJECT SHALL BE REMOVED, CONDUITS SHALL BE CAPPED AND MARKED AS "SPARE" THEN ABANDONED IN PLACE ONCE EMPTY. Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2