Midwestern Engineers, Inc. Plan Preview

EX. MIXED OXIDANT DISINFECTANT ROOM EX. BLOWER/COMPRESSOR ROOM EX. TUBE SETTLER CLARIFIERS - #1 EX. RAPID RATE FILTERS EX. RAPID RATE FILTERS NPW NPW NPW NPW NPW CS CS CS CS CS CS CS CS CS CS CS CS CS CS NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW CS CS CS CS CS CS CS CS CS CS CS CS EX. DISCHARGE LINE STATE OF N 19800122 J O H N W . W E T Z E L P R O F E S S I O N A L E N G I N E E R R E G I S T E R E D I N D I A N A o P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern 2019 9/18/19 BID SET Author: KGAINES, Plot Date: 10/4/2019 9:27 AM Path: Z:\CAD_INCOMPLETE\2018022-00_CITY OF HUNTINGBURG_WS_DISTRIBUTION SYSTEM IMPROVEMENTS AND PLANT UPGRADES\025_PRODUCTIONDWG_DIV 2\12 - MASTER MECHANICAL PLANS.DWG WATER SYSTEM IMPROVEMENTS DIV. II - WATER TREATMENT PLANT IMPROVEMENTS FOR THE CITY OF HUNTINGBURG DUBOIS COUNTY, INDIANA EXISTING CHEMICAL FEED SYSTEMS FLOOR PLAN DEMOLITION SCALE: 1/2" = 1'-0" CFS.04 45 39485 NOTE: · ALL CHEMICAL FEED LINES, EQUIPMENT, AND OTHER APPURTENANCES SHOWN WITH RED CROSS HATCH TO BE REMOVED AND DISPOSED OF IN ACCORDANCE TO LOCAL, STATE AND FEDERAL REGULATIONS. · THE OWNER HAS RIGHTS TO ALL DEMOLISHED MATERIALS. CONTRACTOR TO COORDINATE SALVAGED ITEMS WITH OWNER PRIOR TO ANY DEMOLITION WORK. SALVAGED ITEMS SHALL BE STORED ON SITE AS DIRECTED BY OWNER. COMPRESSOR REMOVE EX. AIR COMPRESSOR, RECEIVER TANK AND APPURTENANCES AND REPLACE WITH NEW FILTER AIR WASH BLOWER. REMOVAL OF THE EXISTING COMPRESSOR MUST BE COMPLETED AFTER THE EXISTING SIXTEEN FILTER ACTUATED VALVES HAVE BEEN CONVERTED FROM PNEUMATICALLY ACTUATED TO ELECTRONICALLY ACTUATED VALVES. CONTRACTOR SHALL ALSO REMOVE THE PNEUMATIC ACTUATOR AIR PIPELINES FROM THE COMPRESSOR TO EACH INDIVIDUAL ACTUATING VALVE. EXISTING CONCRETE HOUSEKEEPING PAD TO BE REMOVED. INSTALL NEW CONCRETE HOUSEKEEPING PAD (SIZE AS REQUIRED UPON APPROVAL OF SHOP DRAWINGS) FOR NEW FILTER AIR WASH BLOWER. CONTRACTOR SHALL REPLACE EXISTING 4" GATE VALVE ON DRAIN LINE EX. PORTABLE DEHUMIDIFIER ALL EXISTING MIXED OXIDANT DISINFECTANT SOLUTION CHEMICAL FEED LINES TO BE REPLACED WITH NEW EXISTING FILTER AIR WASH BLOWER CHEMICAL FEED PIPING LEGEND ALUM CARBON MIXED OXIDANT DISINFECTANT SOLUTION FLUORIDE NON-POTABLE WATER SODIUM PERMANGANATE MISC. CHEMICAL PIPING AL CARBON CS F NPW NaMn04 EX. MIXED OXIDANT STORAGE TANK EXISTING SOFTENERS WILL BE RELOCATED AND REUSED. THE INFLUENT/EFFLUENT WATER LINES SHALL BE RELOCATED/EXTENDED AS NECESSARY EX. METERING PUMPS EX. ELECTROLYTIC CELL (TO REMAIN) "PCP1" EX. ELECTROLYTIC CELL (TO REMAIN) "PCP1" EX. ELECTROLYTIC CELL (TO REMAIN) "PCP1" EX. FILTER AIR WASH BLOWER EX.COMPRESSOR TO BE REMOVED EX. MIXED OXIDANT DISINFECTANT SYSTEM HEATER SHALL BE REMOVED/REPLACED EX. WATER LINES TO BE RELOCATED/ EXTENDED AS NECESSARY EX. WATER SOFTENERS TO BE RELOCATED PLAN SHEET CFS.04 LOCATION 1st FLOOR BUILDING FLOOR PLAN EX. FILL LINE EX. VENT LINE CONTRACTOR SHALL MODIFY EXISTING HOLE THRU EXTERIOR WALL TO ACCOMMODATE FOR NEW 4" VENT LINE EX. MIXED OXIDANT DISINFECTANT HEATER SHALL BE REMOVED AND REPLACED EX. MIXED OXIDANT DISINFECTANT STORAGE TANK TO BE REMOVED EXISTING WATER METER WILL BE RELOCATED AND REUSED. EX. WATER METER TO BE RELOCATED AND REUSED NOTE: ALL POWER OR CONTROL WIRING ASSOCIATED WITH CHEMICAL FEED SYSTEMS OR EQUIPMENT BEING DEMOLISHED WITHIN THE SCOPE OF THIS PROJECT SHALL BE REMOVED, CONDUITS SHALL BE CAPPED AND MARKED AS "SPARE" THEN ABANDONED IN PLACE ONCE EMPTY. RELOCATE EXISTING UNIT HEATER AS REQUIRED TO MAINTAIN CLEARANCES TO NEW AIR PIPING, RECONNECT ELECTRICAL WITHOUT SPLICES. Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2