Midwestern Engineers, Inc. Plan Preview
NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 CS CS CS CS CS CS CS CS CS MIXED OXIDANT DISINFECTANT ROOM BLOWER ROOM CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS NPW CS CS CS CS CS CS CS CS CS CS CS CS CS NPW CS CS CS CS STATE OF N 19800122 J O H N W . W E T Z E L P R O F E S S I O N A L E N G I N E E R R E G I S T E R E D I N D I A N A o P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern 2019 9/18/19 BID SET Author: KGAINES, Plot Date: 10/4/2019 9:30 AM Path: Z:\CAD_INCOMPLETE\2018022-00_CITY OF HUNTINGBURG_WS_DISTRIBUTION SYSTEM IMPROVEMENTS AND PLANT UPGRADES\025_PRODUCTIONDWG_DIV 2\12 - MASTER MECHANICAL PLANS.DWG WATER SYSTEM IMPROVEMENTS DIV. II - WATER TREATMENT PLANT IMPROVEMENTS FOR THE CITY OF HUNTINGBURG DUBOIS COUNTY, INDIANA PROPOSED CHEMICAL FEED SYSTEMS FLOOR PLAN - MIXED OXIDANT DISINFECTANT AND BLOWER ROOM SCALE: 1/2" = 1'-0" CFS.08 49 39481 EXISTING ELECTROLYTIC CELL CONTROL PANEL "PCP1" TO REMAIN 3 PUMP WALL MOUNT SKID ASSEMBLY EXISTING ELECTROLYTIC CELL CONTROL PANEL "PCP1" TO REMAIN IN PLACE 1500 GAL. BULK STORAGE POLYETHYLENE TANK 64" DIA. x 123" TALL 1500 GAL. BULK STORAGE POLYETHYLENE TANK 64" DIA. x 123" TALL MIXED OXIDANT DISINFECTANT - 3 PUMP WALL MOUNT SKID ASSEMBLY DETAILS SCALE: 1/2" = 1'-0" 1500 GAL. BULK STORAGE POLYETHYLENE TANK 64" DIA. x 123" TALL 3 PUMP WALL MOUNT SKID ASSEMBLY 4" PVC SCH. 80 VENT PIPE THRU WALL 4" PVC SCH. 80 VENT PIPE THRU WALL 2" PVC SCH. 80 DISCHARGE LINE 2" FILL LINE ASSEMBLY w/BULKHEAD FITTING & ANTI-FOAM ELBOW 2" PVC SCH. 80 DISCHARGE LINE 2" PVC, SCH. 80 OVERFLOW PIPE 1500 GAL. BULK STORAGE POLYETHYLENE TANK 64" DIA. x 123" TALL PIPING PAINT IDENTIFICATION COLORS PIPE LABEL REQUIREMENTS PIPE DIAMETER MIN LABEL SIZE MIN. LETTER HEIGHT 0.75" TO 1.25" 1" x 8" 0.5" 1.25" TO 2.5" 1" x 8" 0.75" 2.5" TO 8" 2" x 12" 1.25" 8" TO 10" 3" x 24" 2.5" 10" > 4" x 32" 3.5" PIPE LABELS SHALL BE INSTALLED EVERY 25' TO 50' ALONG STRAIGHT RUNS, AT ALL CHANGES IN DIRECTION ON BOTH SIDES OF THE TURN, AT BOTH SIDES OF ENTRY POINTS THROUGH THE FLOORS AND WALLS, NEXT TO ALL FLANGES AND VALVES AND SHALL INCLUDE FLOW DIRECTION OF CONTENTS. IDENTIFICATION LABELS / TAGS SHALL BE INSTALLED ON ALL TANKS, PUMPS, VALVES, METERS AND EQUIPMENT. SANITARY - DARK GREY RAW WATER - OLIVE GREEN FINISH/POTABLE WATER - DARK BLUE CHLORINE (GAS & SOLUTION) - YELLOW ALUM - ORANGE CARBON - BLACK SODIUM PERMANGANATE - PURPLE CHEMICAL FEED PIPING LEGEND ALUM CARBON MIXED OXIDANT DISINFECTANT SOLUTION FLUORIDE NON-POTABLE WATER SODIUM PERMANGANATE MISC. CHEMICAL PIPING AL CARBON CS F NPW NaMn04 NEW ELECTROLYTIC CELL CONTROL PANEL "PCP2" PLAN SHEET CFS.08 LOCATION 2" PVC SCH. 80 DISCHARGE LINE 2" PVC, SCH. 80 INFLUENT LINE 1" PVC, SCH. 80 MIXED OXIDANT DISINFECTANT "POST-FILTER" NORTH FLOW TRAIN FEED LINE 1" PVC, SCH. 80 MIXED OXIDANT DISINFECTANT "POST-FILTER" SOUTH FLOW TRAIN FEED LINE "PRE-FILTER" FEED LINE PUMP "POST-FILTER" NORTH FLOW TRAIN PUMP "POST-FILTER" SOUTH FLOW TRAIN PUMP 1.5" PVC, SCH. 80 WATER LINE 1.5" PVC, SCH. 80 BRINE LINE SEE SHEETS C2.02 FOR MORE INFORMATION 1 C2.02 A CFS.08 SCALE: 1/2" = 1'-0" CHEMICAL FEED SYSTEM - MIXED OXIDANT DISINFECTANT SECTION A 2" PVC SCH. 80 OVERFLOW PIPE 2" PVC SCH. 80 INFLUENT LINE EXISTING FILTER AIR WASH BLOWER NEW FILTER AIR WASH BLOWER 1.5" PVC, SCH. 80 WATER LINE 1.5" PVC, SCH. 80 BRINE LINE 1" PVC, SCH. 80 MIXED OXIDANT DISINFECTANT LINES (TYP. OF THREE) 1" PVC, SCH. 80 MIXED OXIDANT DISINFECTANT "PRE-FILTER" FEED LINE 1st FLOOR BUILDING FLOOR PLAN MIXED OXIDANT DISINFECTANT FEED CONTROL PANEL EXISTING HYDROGEN ALARM TO REMAIN CONTRACTOR SHALL REPLACE EXISTING 4" GATE VALVE ON DRAIN LINE MIXED OXIDANT DISINFECTANT FEED CONTROL PANEL MIXED OXIDANT DISINFECTANT FEED CONTROL PANEL MIXED OXIDANT DISINFECTANT FEED CONTROL PANEL Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2