Midwestern Engineers, Inc. Plan Preview

AL AL AL AL AL NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW 5'-0" NaMn04 NaMn04 NaMn04 AL AL AL AL AL CS CS CS 5'-8" AL AL 7'-0" NEW ALUM ROOM ADDITION SALT STORAGE /MIXED OXIDANT DISINFECTANT SYSTEM ROOM 26" 36" 26" CS AL AL AL AL AL AL AL AL AL NPW NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL NPW NPW NPW NPW NPW NPW M AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL STATE OF N 19800122 J O H N W . W E T Z E L P R O F E S S I O N A L E N G I N E E R R E G I S T E R E D I N D I A N A o P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern 2019 9/18/19 BID SET Author: KGAINES, Plot Date: 10/4/2019 9:29 AM Path: Z:\CAD_INCOMPLETE\2018022-00_CITY OF HUNTINGBURG_WS_DISTRIBUTION SYSTEM IMPROVEMENTS AND PLANT UPGRADES\025_PRODUCTIONDWG_DIV 2\12 - MASTER MECHANICAL PLANS.DWG WATER SYSTEM IMPROVEMENTS DIV. II - WATER TREATMENT PLANT IMPROVEMENTS FOR THE CITY OF HUNTINGBURG DUBOIS COUNTY, INDIANA PROPOSED CHEMICAL FEED SYSTEMS FLOOR PLAN - ALUM AND MIXED OXIDANT DISINFECTANT SCALE: 3/8" = 1'-0" CFS.07 48 39482 2" BALL VALVE AND 2" QUICK CONNECT W/ CAP 2" PVC, SCH. 80 FILL LINE 2" PVC, SCH. 80 FILL LINE 500 GAL. STORAGE BRINE TANK 56" DIA. x 61.5" TALL 2" PVC, SCH. 80 FILL LINE ASSEMBLY w/BULKHEAD FITTING & ANTI-FOAM ELBOW 2" PVC SCH. 80 OVERFLOW PIPE 1" DISCHARGE 2 PUMP WALL ASSEMBLY FOR ALUM FEED SYSTEM 500 GAL. STORAGE BRINE TANK 56" DIA. x 61.5" TALL 2 PUMP WALL ASSEMBLY FOR ALUM FEED SYSTEM ALUM FEED SYSTEM - 2 PUMP WALL ASSEMBLY DETAILS SCALE: 3/4" = 1'-0" PIPING PAINT IDENTIFICATION COLORS PIPE LABEL REQUIREMENTS PIPE DIAMETER MIN LABEL SIZE MIN. LETTER HEIGHT 0.75" TO 1.25" 1" x 8" 0.5" 1.25" TO 2.5" 1" x 8" 0.75" 2.5" TO 8" 2" x 12" 1.25" 8" TO 10" 3" x 24" 2.5" 10" > 4" x 32" 3.5" PIPE LABELS SHALL BE INSTALLED EVERY 25' TO 50' ALONG STRAIGHT RUNS, AT ALL CHANGES IN DIRECTION ON BOTH SIDES OF THE TURN, AT BOTH SIDES OF ENTRY POINTS THROUGH THE FLOORS AND WALLS, NEXT TO ALL FLANGES AND VALVES AND SHALL INCLUDE FLOW DIRECTION OF CONTENTS. IDENTIFICATION LABELS / TAGS SHALL BE INSTALLED ON ALL TANKS, PUMPS, VALVES, METERS AND EQUIPMENT. SANITARY - DARK GREY RAW WATER - OLIVE GREEN FINISH/POTABLE WATER - DARK BLUE CHLORINE (GAS & SOLUTION) - YELLOW ALUM - ORANGE CARBON - BLACK SODIUM PERMANGANATE - PURPLE CHEMICAL FEED PIPING LEGEND ALUM CARBON MIXED OXIDANT DISINFECTANT SOLUTION FLUORIDE NON-POTABLE WATER SODIUM PERMANGANATE MISC. CHEMICAL PIPING AL CARBON CS F NPW NaMn04 THREE (3) 1050 GAL. BULK STORAGE POLYETHYLENE DOUBLE WALL ALUM TANKS 72" DIA. x 87" TALL RELOCATED WATER SOFTENERS 1050 GAL. BULK STORAGE POLYETHYLENE DOUBLE WALL ALUM TANK 72" DIA. x 87" TALL (TYPICAL OF 3) BULK SALT STORAGE AREA EXISTING EYE WASH TO REMAIN 4" PVC, SCH. 40 VENT PIPE THRU WALL 4" VENT THRU WALL 4" VENT THRU WALL 2 STEP ALUMINUM LADDER WITH LEFT HANDRAIL BY COTTERMAN.COM MODEL No. AM-202 4" PVC, SCH. 80 VENT PIPE 2" PVC SCH. 80 CONDUIT W/ 3 4 " REINFORCED CLEAR PVC TUBING WITH POLYESTER BRAID CARRIER PIPE NEW WATER HEATER 1.5" PVC, SCH. 80 WATER LINE 1.5" PVC, SCH. 80 BRINE LINE EXTEND 2" WATER SUPPLY LINE SALT PALLET STORAGE SALT PALLET STORAGE SALT PALLET STORAGE SALT PALLET STORAGE SALT PALLET STORAGE SALT PALLET STORAGE SALT PALLET STORAGE SALT PALLET STORAGE 2" PVC, SCH. 80 OVERFLOW PIPE 2" PVC SCH. 80 CONDUIT W/ 3 4 " REINFORCED CLEAR PVC TUBING WITH POLYESTER BRAID CARRIER PIPE 1" PVC, SCH. 80 TO TIE IN POINT TO EX. ALUM FEED LINE 1.5" PVC, SCH. 80 WATER LINE B CFS.07 A CFS.07 SCALE: 1/2 = 1'-0" ALUM FEED SYSTEM - SECTION A 1.5" PVC, SCH. 80 BRINE LINE 1.5" PVC, SCH. 80 WATER LINE EXTEND 2" WATER SUPPLY LINE NEW WATER HEATER SCALE: 1/2 = 1'-0" MIXED OXIDANT DISINFECTANT FEED SYSTEM - SECTION B CONNECT TO EX. ALUM FEED LINE PLAN SHEET CFS.07 LOCATION 1st FLOOR BUILDING FLOOR PLAN INSTALL NEW BALL VALVE AND RAW WATER SAMPLE LINE PUMP ON EXISTING 1" LINE. PUMP SHALL BE STENNER PUMP COMPANY, MODEL 85M5, 85 GPD, 120 V OR EQUAL. OFF PUMP DISCHARGE INSTALL 3 4 " PVC, SCH. 80 PIPE WITH BALL VALVE FOR SAMPLING PURPOSES. INSTALL PVC FUNNEL WITH 1 1 2 " SCH. 40 PVC DRAIN LINE SAW CUT EXISTING CONCRETE TO INSTALL NEW 1 1 2 " DRAIN LINE AND REPAIR. TWO (2) NEW 3" FLOOR DRAINS TO TIE INTO EXISTING 6" DRAIN. EXACT LOCATION OF THE EXISTING DRAIN LINE TO BE DETERMINED IN FIELD CONTRACTOR SHALL REPLACE EXISTING 4" GATE VALVE ON DRAIN LINE NEW CHEMICAL FEED SCADA REMOTE I/O PANEL RELOCATED WATER SOFTENERS 1.5" PVC, SCH. 80 WATER LINE 1" PVC, SCH. 80 ALUM FEED LINE RELOCATED EX. METER EX. 1" POLYETHYLENE CHEMICAL FEED LINE SHALL BE CONVERTED TO A RAW WATER SAMPLING LINE. CONTRACTOR SHALL RELOCATE/REPLACE AS REQUIRED TO INSTALL THE NEW ALUM ROOM ADDITION NOTES: 1. ALL PIPING, VALVES AND FITTINGS SHALL BE 1 2 " SCH. 80 CPVC SOCKET WELD WITH VITON SEALS UNLESS OTHERWISE NOTED PIPING SCHEMATIC Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2