Midwestern Engineers, Inc. Plan Preview

EX. AMMONIA ROOM CLEARWELL NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW E E F F F F F F F F F F F F F F F F F F F F DRY WELL CHEMICAL FEED ZONE FLUORIDE STATE OF N 19800122 J O H N W . W E T Z E L P R O F E S S I O N A L E N G I N E E R R E G I S T E R E D I N D I A N A o P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern 2019 9/18/19 BID SET Author: KGAINES, Plot Date: 10/4/2019 9:28 AM Path: Z:\CAD_INCOMPLETE\2018022-00_CITY OF HUNTINGBURG_WS_DISTRIBUTION SYSTEM IMPROVEMENTS AND PLANT UPGRADES\025_PRODUCTIONDWG_DIV 2\12 - MASTER MECHANICAL PLANS.DWG WATER SYSTEM IMPROVEMENTS DIV. II - WATER TREATMENT PLANT IMPROVEMENTS FOR THE CITY OF HUNTINGBURG DUBOIS COUNTY, INDIANA EXISTING CHEMICAL FEED SYSTEMS FLOOR PLAN DEMOLITION SCALE: 1/2" = 1'-0" CFS.06 47 39483 NOTE: · ALL CHEMICAL FEED LINES, EQUIPMENT, AND OTHER APPURTENANCES SHOWN WITH RED CROSS HATCH TO BE REMOVED AND DISPOSED OF IN ACCORDANCE TO LOCAL, STATE AND FEDERAL REGULATIONS. · THE OWNER HAS RIGHTS TO ALL DEMOLISHED MATERIALS. CONTRACTOR TO COORDINATE SALVAGED ITEMS WITH OWNER PRIOR TO ANY DEMOLITION WORK. SALVAGED ITEMS SHALL BE STORED ON SITE AS DIRECTED BY OWNER. AMMONIA SYSTEM CONTROL PANEL TO BE REMOVED REMOVE ALL AMMONIA CHEMICAL FEED, METERING PUMPS, EQUIPMENT AND ASSOCIATED APPURTENANCES CUT & CAP FLUSH WITH FLOOR AND REMOVE THE EXISTING AMMONIA CHEMICAL FEED LINES. REUTILIZE CONDUIT TO THE EXTENT POSSIBLE FOR NEW SODIUM PERMANGANATE CHEMICAL FEED LINE TO RAW WATER PUMP STATION CUT & CAP FLUSH WITH FLOOR REMOVE THE EXISTING AMMONIA CHEMICAL FEED LINE TO AMMONIA TANK AND INSTALL A "PULL WIRE" FOR FUTURE IN EXISTING CONDUIT ALL FLUORIDE EQUIPMENT AND FLUORIDE CHEMICAL FEED LINES TO BE REMOVE AND REPLACED WITH NEW IN THE FUTURE SODIUM FLUORIDE/SODIUM PERMANGANATE ROOM REMOVE EX. AMMONIA TANK, FENCE, AND APPURTENANCES FLUSH WITH THE EX. CONCRETE. PATCH AND REPAIR CONCRETE AS NECESSARY EX. EYE WASH (TO REMAIN) EX. CONTAINMENT PALLET CUT AND CAP WATER SUPPLY TO THE EYE WASH AT THE TEE AND REMOVE EYE WASH AND APPURTENANCES CHEMICAL FEED PIPING LEGEND ALUM CARBON MIXED OXIDANT DISINFECTANT SOLUTION FLUORIDE NON-POTABLE WATER SODIUM PERMANGANATE MISC. CHEMICAL PIPING AL CARBON CS F NPW NaMn04 (PROPOSED SODIUM FLUORIDE SODIUM PERMANGANATE ROOM) EX. AMMONIA PIPING TO BE REMOVED AMMONIA METERING PUMPS TO BE REMOVED REMOVE CONDUIT CABLING TO THE AMMONIA SYSTEM ALARM REMOVE THIS DRAIN LINE FROM THIS POINT TO THE AMMONIA ROOM CUT AND CAP SUPPLY TO THE EYE WASH AT THE TEE TO THE MAIN LINE AND REMOVE EYE WASH CUT AND CAP FEED LINE FLUSH WITH THE EX. CONCRETE AMMONIA STORAGE TANK / FENCE ON S.E. SIDE OF WTP BUILDING EX. FLUORIDE SATURATOR TANK REMOVE EXISTING SODIUM FLUORIDE FEED LINES TO THE INJECTION POINTS IN THE CHEMICAL MIXING ZONE, INCLUSIVE OF THE DIFFUSERS AMMONIA SYSTEM CONTROL PANEL EX. AMMONIA METERING PUMPS PLAN SHEET CFS.06 LOCATION 1st FLOOR BUILDING FLOOR PLAN EX. AMMONIA SYSTEM ALARM NOTE: ALL POWER OR CONTROL WIRING ASSOCIATED WITH CHEMICAL FEED SYSTEMS OR EQUIPMENT BEING DEMOLISHED WITHIN THE SCOPE OF THIS PROJECT SHALL BE REMOVED, CONDUITS SHALL BE CAPPED AND MARKED AS "SPARE" THEN ABANDONED IN PLACE ONCE EMPTY. Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2