Midwestern Engineers, Inc. Plan Preview
NPW NPW NPW CS 8" 10" CS CS NPW NPW NPW NPW NPW M NPW NPW F F F F F F F F F F F F F F NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 HOPPER LC LC DESTACO53310331 DESTACO53310331 CWETTINGCONE L NPW NPW NPW CARBON CARBON CARBON CARBON CARBON CARBON CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS F F F F F F F F F F F F F AL AL AL AL AL AL AL AL FLOW NaMn04 AL AL AL AL AL AL NaMn04 NaMn04 4" PVC SCH. 40 VENT PIPE STATE OF N 19800122 J O H N W . W E T Z E L P R O F E S S I O N A L E N G I N E E R R E G I S T E R E D I N D I A N A o P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern 2019 9/18/19 BID SET Author: KGAINES, Plot Date: 10/4/2019 9:33 AM Path: Z:\CAD_INCOMPLETE\2018022-00_CITY OF HUNTINGBURG_WS_DISTRIBUTION SYSTEM IMPROVEMENTS AND PLANT UPGRADES\025_PRODUCTIONDWG_DIV 2\12 - MASTER MECHANICAL PLANS.DWG WATER SYSTEM IMPROVEMENTS DIV. II - WATER TREATMENT PLANT IMPROVEMENTS FOR THE CITY OF HUNTINGBURG DUBOIS COUNTY, INDIANA PROPOSED CHEMICAL FEED SYSTEM SCHEMATICS DO NOT SCALE CFS.11 52 39478 CHEMICAL FEED PIPING LEGEND ALUM CARBON MIXED OXIDANT DISINFECTANT SOLUTION FLUORIDE NON-POTABLE WATER PIPING PAINT IDENTIFICATION COLORS PIPE LABEL REQUIREMENTS PIPE DIAMETER MIN LABEL SIZE MIN. LETTER HEIGHT 0.75" TO 1.25" 1" x 8" 0.5" 1.25" TO 2.5" 1" x 8" 0.75" 2.5" TO 8" 2" x 12" 1.25" 8" TO 10" 3" x 24" 2.5" 10" > 4" x 32" 3.5" PIPE LABELS SHALL BE INSTALLED EVERY 25' TO 50' ALONG STRAIGHT RUNS, AT ALL CHANGES IN DIRECTION ON BOTH SIDES OF THE TURN, AT BOTH SIDES OF ENTRY POINTS THROUGH THE FLOORS AND WALLS, NEXT TO ALL FLANGES AND VALVES AND SHALL INCLUDE FLOW DIRECTION OF CONTENTS. IDENTIFICATION LABELS / TAGS SHALL BE INSTALLED ON ALL TANKS, PUMPS, VALVES, METERS AND EQUIPMENT. AL CARBON CS F NPW SANITARY - DARK GREY RAW WATER - OLIVE GREEN FINISH/POTABLE WATER - DARK BLUE CHLORINE (GAS & SOLUTION) - YELLOW ALUM - ORANGE CARBON - BLACK SODIUM PERMANGANATE - PURPLE SODIUM PERMANGANATE NaMn04 MISC. CHEMICAL PIPING POWDER ACTIVATED CARBON SYSTEM SCHEMATIC LIQUID ALUM SYSTEM SCHEMATIC MIXED OXIDANT DISINFECTANT SYSTEM SCHEMATIC SODIUM FLUORIDE SYSTEM SCHEMATIC SODIUM PERMANGANATE SYSTEM SCHEMATIC 2" FILL LINE ASSEMBLY w/BULKHEAD FITTING & ANTI-FOAM ELBOW 500 GAL. STORAGE BRINE TANK 56" DIA. x 61.5" TALL 2 PUMP WALL ASSEMBLY RELOCATED WATER SOFTENING SYSTEM 1050 GAL. BULK STORAGE POLYETHYLENE DOUBLE WALL ALUM TANK 72" DIA. x 87" TALL (TYPICAL OF THREE) CLEAR WELL TYPICAL OF BOTH NEW NORTH FLOW TRAIN AND EXISTING SOUTH FLOW TRAIN EXISTING WTP INLET PIPING NEW INTAKE PUMP STATION ELECTROLYTIC CELL (ONE (1) EXISTING AND ONE (1) PROPOSED) 1500 GAL. BULK STORAGE POLYETHYLENE TANK 64" DIA. x 123" TALL (TYPICAL OF TWO) 3 PUMP WALL MOUNT SKID ASSEMBLY 2" PVC SCH. 80 PVC DISCHARGE LINE 80 GAL. BULK STORAGE POLYETHYLENE TANK 24" DIA. x 49" TALL 2 PUMP WALL SKID ASSEMBLY 3 8 " SCH. 80 PVC FLUORIDE DISCHARGE WATER SOFTENING SYSTEM 4" VENT PIPE THRU WALL 2" BALL VALVE FERNCO PIPE CLAMP PIPE SUPPORT BRACKET w/S.S. BOLTS 2" QUICK CONNECT w/CAP 2" FILL LINE ASSEMBLY w/BULKHEAD FITTING & ANTI-FOAM ELBOW EXISTING INJECTION POINTS EXISTING INJECTION POINTS 1" SS BALL VALVE 1" UNION 1 1/4" x 1" REDUCER 1" TAPERED PIPE THREAD FEMALE CONNECTOR, SWAGELOK SS-1610-7-16 1" 90 ELBOW 1 1/4" SCH. 80 PVC FEMALE CONNECTOR SWAGELOK SS-160-7-16, PH. (317) 248-2468 VALVE AND FITTING CAJON # SS-16BHT-48, INDIANAPOLIS STAINLESS STEEL HOSE, 1" x 48" FLEXIBLE TFE WALL, PH. (317) 248-2468 FLEXIBLE HOSE CONNECTOR PIPE THREAD FOR W/ 1" TAPERED SOLUTION TUBE ASSEMBLY 1" CORP. COCK & NOT TO SCALE STOPCOCK AND DIFFUSER DETAIL FINISHED FLOOR FINISHED FLOOR (2ND FLOOR) FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR EXISTING GRATE EXISTING CONTAINMENT AREA EXISTING GRADE FINISHED FLOOR NEW WTP BUILDING ADDITION EXTERIOR WALL NEW INJECTION POINT TO EXISTING INJECTION POINTS (SOUTH FLOW TRAIN) 2" PVC CONDUIT W/ 3 4 " PVC BRAIDED TUBING 80 GALLON CONTAINMENT PALLET TO FLOCCULATORS FROM INTAKE PUMP STATION FROM EXISTING LAKE INTAKE STRUCTURE CONTRACTOR TO REUSE EXISTING CARBON FEED PIPING TO THE INJECTION POINT CONTRACTOR TO REUSE EXISTING ALUM FEED PIPING FROM THE FUTURE SALT STORAGE ROOM TO THE INJECTION POINT CONTRACTOR TO INSTALL NEW MIXED OXIDANT DISINFECTANT FEED LINES TO THE INJECTION POINTS CONTRACTOR TO INSTALL NEW SODIUM FLUORIDE FEED LINES TO THE INJECTION POINTS CONTRACTOR TO REUSE EXISTING NPW PIPING CONTRACTOR TO INSTALL NEW SODIUM PERMANGANATE FEED LINE TO THE INJECTION POINTS TO EXISTING WTP INLET PIPING SODIUM FLUORIDE SKID ASSEMBLY FROM RAPID RATE FILTERS DRY WELL 2" PVC SCH. 80 FILL LINE EXISTING WALL 1" PVC SCH. 80 CONTRACTOR TO INSTALL NEW ALUM FEED PIPING FROM THE METERING PUMPS TO THE FUTURE SALT STORAGE ROOM 2" WATER SUPPLY LINE WATER HEATER 1.5" PVC SCH. 80 WATER LINE 1.5" PVC SCH. 80 BRINE LINE CONTRACTOR TO INSTALL NEW MIXED OXIDANT DISINFECTANT FEED LINES TO THE INJECTION POINTS 1" PVC SCH. 80 1" PVC SCH. 80 TO NEW INJECTION POINTS (NORTH FLOW TRAIN) NEW PAC FEEDER / WETTING CONE SYSTEM INSTALL NEW STOP COCK & DIFFUSER. SEE DETAIL THIS SHEET INSTALL NEW 3 4 " REINFORCED CLEAR PVC TUBING WITH POLYESTER BRAID SODIUM PERMANGANATE CHEMICAL FEED LINE IN 2" PVC SCH. 80 CONDUIT FROM WTP TO NEW INTAKE PUMP STATION 2" PVC, SCH. 80 INFLUENT LINE 3 4 " PVC, SCH. 80 3 4 " PVC, SCH. 80 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2