MAINREFERENCEPOINT 1'-2" 60' 1'-2" 1'-2" GENERAL ELECTRICAL NOTES ALL BUILDING WORK SHALL COMPLY WITH INDIANA ELECTRICAL AND BUILDING CODES, LATEST EDITION. DOOR TRIM AND TRIM KITS TO BE INCLUDED FOR ALL PANELBOARDS. NO MORE THAN SIX CURRENT CARRYING CONDUCTORS (INCLUDING NEUTRAL CONDUCTORS) IN ANY ONE CONDUIT CARRYING 20-AMP LIGHTING, OR RECEPTACLE LOADS. ALL OTHER CIRCUITS SHALL BE IN A DEDICATED CIRCUIT. ALL RECEPTACLES AND SWITCHES SHALL BE INDUSTRIAL GRADE, RATED AT 20A. ALL POWER AND CONTROL CIRCUIT WIRING USED SHALL BE "THWN" COPPER UNLESS OTHERWISE SPECIFIED OR REQUIRED BY CODE. PER NEC 210.10, ALL WIRING SHALL BE SIZED TO COORDINATE WITH TEMPERATURE RATINGS OF TERMINATIONS. LISTED WIRE SIZES ON PANELBOARD SCHEDULES ARE MINIMUM SIZES. SIZE WIRE TO MEET TEMPERATURE AND VOLTAGE DROP REQUIREMENTS. CONDUIT TYPES: FILTER ROOM CONDUIT RUNS SHALL TYPICALLY MATCH EXISTING. POWDER ACTIVATED CARBON FEED ROOM SHALL BE UPDATED TO CLASS 1 DIV. 2 PER NEC. BURIED CONDUITS AND INTERIOR SURFACE MOUNT CONDUITS NOT OTHERWISE NOTED SHALL TYPICALLY BE SCH. 80 PVC. EXPOSED EXTERIOR CONDUITS SHALL BE ALUMINUM FASTENED WITH STAINLESS HARDWARE. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO QUANTIFY, SIZE, PROVIDE AND INSTALL ALL REQUIRED PULL/JUNCTION BOXES PER NEC. BURIED BOXES SHALL BE QUAZITE OR EQUAL; EXTERIOR PULL BOXES SHALL BE NEMA 4X S.S. ALL OTHER PULL/JUNCTION BOXES REQUIRED FOR THIS PROJECT SHALL TYPICALLY MATCH THE CONDUIT TYPE USED FOR THAT APPLICATION PER THE ABOVE SCHEDULE. ALUMINUM UNISTRUT, STAINLESS STEEL ANCHORS, AND STAINLESS STEEL HARDWARE SHALL BE USED FOR SUPPORT OF ALL ELECTRICAL EQUIPMENT. PROVIDE GROUND CONDUCTOR IN ALL CONDUITS. SIZE PER NATIONAL ELECTRIC CODE. ALL ELECTRICAL SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE ENTIRE ELECTRICAL SYSTEM SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. THE ELECTRICAL CONTRACTOR, UNLESS OTHERWISE NOTED, SHALL FURNISH AND INSTALL ALL MATERIAL AND EQUIPMENT AS INDICATED ON THE DRAWINGS. MATERIALS AND EQUIPMENT SHALL BE NEW AND OF FIRST CLASS CONSTRUCTION, AND SHALL BE THE PRODUCT OF AN ESTABLISHED AND REPUTABLE MANUFACTURER, AND SHALL BE DESIGNED TO PERFORM THE SERVICE REQUIRED. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL HARDWARE, WIRE, BOXES, LAMPS, ACCESSORIES, SWITCHES, FLOATS, CONTROL DEVICES, ETC. AS REQUIRED FOR A COMPLETE AND WORKING SYSTEM. WHILE THESE PLANS AND SPECIFICATIONS HAVE MADE A BEST EFFORT TO CAPTURE ALL RELATED SCOPE FOR THIS PROJECT IT SHALL BE UNDERSTOOD THAT CERTAIN CHANGES MAY HAVE TO BE MADE TO ACCOMMODATE THE APPROVED SHOP DRAWING SUBMITTALS REVIEWED DURING CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER. MULTI-WIRE (SHARED NEUTRAL CIRCUITS) SHALL NOT BE USED. PROVIDE A NEUTRAL CONDUCTOR FOR EACH LINE-TO-NEUTRAL CIRCUIT. MOUNT ALL DEVICES FLUSH UNLESS OTHERWISE SPECIFIED. ALL CONDUIT SHALL BE CONCEALED AS MUCH AS PRACTICAL., UNLESS MATCHING EXISTING DICTATES OTHERWISE. IT IS THE CONTRACTORS RESPONSIBILITY TO ENSURE EXISTING SCADA SYSTEM IS OPERATIONAL DURING CONSTRUCTION. IT SHALL BE THE RESPONSIBILITY OF THE INSTALLING GENERAL CONTRACTOR AND/OR THEIR ELECTRICIAN AND SCADA SYSTEM INTEGRATOR TO COORDINATE I/O AT EACH END DEVICE WITH REGARDS TO SPECIFIC CONDUIT AND WIRE REQUIREMENTS. SEPARATE DIGITAL, ANALOG, ETHERNET AND FIBER TO DEDICATED CONDUIT RUNS FROM END DEVICE TO MCP IN LAB AS MUCH AS PRACTICAL. PROPOSED UPGRADES TO THE TREATMENT PLANT PROCESS AND EQUIPMENT SHALL MIRROR EXISTING CONSTRUCTION AND FUNCTIONALITY UNLESS SPECIFICALLY CALLED OUT OTHERWISE. ALL DISRUPTIONS TO THE TREATMENT PLANT OPERATION, POWER OR SCADA, SHALL BE COORDINATED WITH THE OWNER A MINIMUM OF 72 HOURS IN ADVANCE. THE CONTRACTOR SHALL COOPERATE WITH OWNER AND ENGINEER PERTAINING TO SEQUENCING CERTAIN ASPECTS OF CONSTRUCTION DURING THE PROJECT TO MINIMIZE CRITICAL SHUTDOWNS. P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern 2019 BID SET Author: CMOODY, Plot Date: 10/4/2019 7:48 AM Path: Z:\CAD_INCOMPLETE\2018022-00_CITY OF HUNTINGBURG_WS_DISTRIBUTION SYSTEM IMPROVEMENTS AND PLANT UPGRADES\025_PRODUCTIONDWG_DIV 2\ELECTRICAL SITE PLANS.DWG WATER SYSTEM IMPROVEMENTS DIV. II - WATER TREATMENT PLANT IMPROVEMENTS FOR THE CITY OF HUNTINGBURG DUBOIS COUNTY, INDIANA STATE OF No. PE11100002 A L A N F . B U R C H P R O F E S S I O N A L E N G I N E E R R E G I S T E R E D I N D I A N A E.01 39477 SLUDGE BLOW DOWN VALVE VAULT 8" DUFF WATER 14" PLRWSD 8" PVC SANITARY SEWER 8" WATER 12" PVC STORM SEWER 8" PVC CONCRETE 6" DRAIN PIPE EXISTING ELECTRICAL EQUIPMENT ROOM TO REMAIN, SEE FLOOR PLAN AND ONE LINE DIAGRAM FOR MORE INFORMATION. EXISTING PAD MOUNT TRANSFORMER BY CITY OF HUNTINGBURG TO REMAIN 8" PVC 12" FINISHED WATER EXISTING WATER TREATMENT PLANT 16" BACKWASH LINE 12" INFLUENT 8" SLUDGE LINE 8" 4" 2" GAS MAIN M.H. (3) 12" D.I. PIPES METER M.H. 8" WATER TO WTP 12" FINISHED WATER 18" INFLUENT EXISTING RAW INTAKE PUMP STATION TO BE DEMOLISHED. REMOVE WIRE, CAP CONDUITS AND ABANDON IN PLACE. ALL EQUIPMENT UNUSED AT COMPLETION OF PROJECT SHALL BE REMOVED. EXISTING CHEMICAL FEED LINES 12" PVC 4" 4" EXISTING BLOW DOWN TANK EXISTING BACKWASH TANK STONE NEW SLUDGE DRYING BEDS 8" DUFF WATER 14" PLRWSD M.H. 8" F/M 8" EXISTING OUTFALL STRUCTURE 18" 12" 14" 12" 12" BYPASS 404,000 GALLON CLEARWELL 8" WATER MAIN TO WTP 12" WATER MAIN TO SYSTEM 18" HIGH SERVICE PUMP STATION 10" MASTER METER CONNECTION TO DUFF WATER 8" MAG METER EXISTING INTAKE STRUCTURE HUNTINGBURG LAKE S.R. 64 PROPOSED OVERALL ELECTRICAL SITE PLAN SCALE: 1" = 40' CONTRACTOR TO PULLOUT EXISTING POWER AND CONTROL WIRING, CONDUITS TO BE ABANDONED IN PLACE. REMOVE AS NEEDED TO CONSTRUCT PROPOSED PROJECT. TWO (2) 1" CONTROL CONDUITS & WIRE FROM SCADA TO RAW PUMP STATION WET WELL TWO (2) 480V-3Ø FEEDERS TO RAW PUMP STATION EXISTING UNDERGROUND PRIMARY ELECTRIC SERVICE BY CITY OF HUNTINGBURG TO REMAIN, FIELD LOCATE BY HAND PROPOSED RAW PUMP STATION ONE (1) 1" SPARE CONDUIT TO RAW PUMP STATION EXISTING UNDERGROUND ELECTRIC SERVICE INTO BUILDING TO REMAIN AMMONIA TANK 2 RUNS (3) #400 MCM THWN (1) #1 CU. GND. 4" CONDUIT PROPOSED BLOW DOWN TANK PROPOSED BACKWASH TANK EXISTING SLUDGE/RECYCLE PUMPS TO BE REMOVED AND REPLACED, SEE CIVIL AND ONE LINE DIAGRAMS FOR ADDITIONAL INFORMATION FIELD LOCATE PROPOSED 600A FEEDER AND FIBER LINE w/ OWNER AND ENGINEER DURING CONSTRUCTION (MIN. 18" COVER). RETURN ALL DISTURBED SURFACES TO PRE-CONSTRUCTION CONDITION. THIS WORK SHALL BE ACCOMPLISHED EARLY IN THE CONSTRUCTION SCHEDULE TO ALLOW OTHER CRITICAL PHASES TO BE COMPLETED. SOLAR FIELD TO BE CONSTRUCTED IN SEPARATE BUT CONCURRENTLY TIMED PROJECT. NOTE: CONTRACTOR SHALL UTILIZE LONG SWEEP ELBOWS AS STANDARD; QUANTIFY AND SIZE PULL BOXES AS REQUIRED PER NEC. PROPOSED FIBER NETWORK IN 2" SCH. 80 PVC FROM MCP IN OFFICE TO RTU IN H.S. PUMP BUILDING 120V-1Ø FOR RECEPTACLE Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2