Midwestern Engineers, Inc. Plan Preview
NPW NPW NPW NPW NPW CS NPW AL AL KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 KMNO4 AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL AL CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CARBON CARBON CARBON CARB N CARBON CARBON CARBON CARBON CARBON CARBON CARBON CARBON CARBON CARBON NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW CS NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS F F F F F F F F F F F F F F F F F F F F F NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 AL F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F CS CS NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW CS CS CS CS CS CS CS CS CS CS CS NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW NPW CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS F F F F F F F F F F F F F F F F F CS F CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS F CS F CS F CS F NPW NPW NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 NaMn04 CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS NPW NPW NPW NPW NPW GFI GFI GFI GFI GFI FILTER CONTROL PANEL (FCP#) NEMA 4X S.S. 30A, 120V ETHERNET TO MFCP FILTER ISOLATION VALVES (TYP. OF 4) INFLUENT VALVES (TYP. OF 4) BACKWASH EFFLUENT VALVES (TYP. OF 4) FILTER TO WASTE VALVES (TYP. OF 4) AIRWASH SUPPLY VALVES (TYP. OF 4) 120V-1Ø IN CONDUIT CONTROL IN CONDUIT 120V-1Ø IN CONDUIT CONTROL IN CONDUIT 120V-1Ø IN CONDUIT CONTROL IN CONDUIT 120V-1Ø IN CONDUIT SUPPLEMENTAL BACKWASH SUPPLY VALVE CONTROL IN CONDUIT 36"x36"x10" NEMA 4X S.S. NOTE: CONTRACTOR TO PROVIDE AND INSTALL REMOTE I/O PANELS ON ALUMINUM UNISTRUT STANDS, FASTEN w/ STAINLESS HARDWARE F F F F F CS CS CS CS CS CS F SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL SL DL DL DL DL CENTRALATOR ELECTRICAL AND CONTROL IMPROVEMENTS SCALE: 1 4 " = 1'-0" P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern 2019 BID SET Author: CMOODY, Plot Date: 10/4/2019 7:55 AM Path: Z:\CAD_INCOMPLETE\2018022-00_CITY OF HUNTINGBURG_WS_DISTRIBUTION SYSTEM IMPROVEMENTS AND PLANT UPGRADES\025_PRODUCTIONDWG_DIV 2\MEP PLANS.DWG WATER SYSTEM IMPROVEMENTS DIV. II - WATER TREATMENT PLANT IMPROVEMENTS FOR THE CITY OF HUNTINGBURG DUBOIS COUNTY, INDIANA STATE OF No. PE11100002 A L A N F . B U R C H P R O F E S S I O N A L E N G I N E E R R E G I S T E R E D I N D I A N A FLOCCULATORS EXISTING TUBE SETTLER CLARIFIER #1 EXISTING TUBE SETTLER CLARIFIER #2 PROPOSED TUBE SETTLER CLARIFIER #3 PROPOSED TUBE SETTLER CLARIFIER #4 EXISTING FLOCCULATOR MOTOR #4 STARTER/ DISCONNECT EXISTING FLOCCULATOR MOTOR #3 STARTER/ DISCONNECT EXISTING FLOCCULATOR MOTOR #1 STARTER/ DISCONNECT PROPOSED FLOCCULATOR MOTOR #8 VFD/ DISCONNECT PROPOSED FLOCCULATOR MOTOR #7 VFD/ DISCONNECT PROPOSED FLOCCULATOR MOTOR #5 VFD/ DISCONNECT PROPOSED CENTRALATOR #1 MAG METER PROPOSED CENTRALATOR #2 MAG METER EXISTING FILTER CONTROL PANEL (FCP1) TO BE REMOVED AND REPLACED PROPOSED FILTER CONTROL PANEL (FCP2), FIELD VERIFY DIMENSIONS PRIOR TO INSTALLATION PROPOSED CENTRALATOR #3 MAG METER PROPOSED CENTRALATOR #4 MAG METER FILTER CELL #1 FILTER CELL #2 FILTER CELL #3 FILTER CELL #4 EXISTING FILTER #3 INFLUENT VALVE EXISTING FILTER #4 INFLUENT VALVE EXISTING FILTER #1 INFLUENT VALVE EXISTING FILTER #2 INFLUENT VALVE EXISTING FILTER #1 AIRWASH SUPPLY VALVE EXISTING FILTER #2 AIRWASH SUPPLY VALVE EXISTING FILTER #3 AIRWASH SUPPLY VALVE EXISTING FILTER #4 AIRWASH SUPPLY VALVE NOTE: AIR SUPPLY VALVES ARE NC, ENERGIZE TO OPEN FILTER CELL #5 FILTER CELL #6 FILTER CELL #7 FILTER CELL #8 PROPOSED FILTER #7 INFLUENT VALVE PROPOSED FILTER #8 INFLUENT VALVE PROPOSED FILTER #5 INFLUENT VALVE PROPOSED FILTER #6 INFLUENT VALVE FILTER CELL #6 ISOLATION VALVE FILTER CELL #5 ISOLATION VALVE FILTER CELL #7 ISOLATION VALVE FILTER CELL #8 ISOLATION VALVE FILTER CELL #2 ISOLATION VALVE FILTER CELL #1 ISOLATION VALVE FILTER CELL #3 ISOLATION VALVE FILTER CELL #4 ISOLATION VALVE BLOW DOWN VALVE #4 BLOW DOWN VALVE #2 BLOW DOWN VALVE #1 BLOW DOWN VALVE #3 NOTE: BLOW DOWN VALVES ARE NC, ENERGIZE TO OPEN CONTROL WIRING IN CONDUIT TO FCP2 PER I/O LIST 120V-1Ø POWER WIRING IN CONDUIT TO FCP2 CONTROL WIRING IN CONDUIT TO FCP2 PER I/O LIST CONTROL WIRING IN CONDUIT TO FCP2 PER I/O LIST CONTROL WIRING IN CONDUIT TO FCP2 PER I/O LIST CONTROL WIRING IN CONDUIT TO FCP1 PER I/O LIST CONTROL WIRING IN CONDUIT TO FCP1 PER I/O LIST CONTROL WIRING IN CONDUIT TO FCP1 PER I/O LIST CONTROL WIRING IN CONDUIT TO FCP1 PER I/O LIST 120V-1Ø POWER WIRING IN CONDUIT TO FCP2 ETHERNET TO MASTER FILTER CONTROL PANEL NEW REMOTE I/O PANEL (FCP1) 30A, 120V POWER CIRCUIT TO LXD-22 CONTROL WIRING IN CONDUIT TO FCP1 PER I/O LIST CONTROL WIRING IN CONDUIT TO FCP1 PER I/O LIST 120V-1Ø POWER WIRING IN CONDUIT TO FCP1 ETHERNET TO MASTER FILTER CONTROL PANEL NEW REMOTE I/O PANEL (FCP2) 30A, 120V POWER CIRCUIT TO LXD-24 CONTROL WIRING IN CONDUIT TO FCP2 PER I/O LIST CONTROL WIRING IN CONDUIT TO FCP2 PER I/O LIST 120V-1Ø POWER WIRING IN CONDUIT TO FCP2 CONTROL TO MFCP CONTROL TO MFCP CONTROL TO MFCP CONTROL TO MFCP PROPOSED FLOCCULATOR MOTOR #6 VFD/ DISCONNECT EXISTING FLOCCULATOR MOTOR #2 STARTER/ DISCONNECT OUTLET IN PIT FOR SAMPLE PUMP TO TURBIDIMETER, INTERLOCKED FROM SCADA w/ RAW PUMPS (TYPICAL OF 4, MATCH EXISTING LAYOUT FOR PROPOSED FILTERS #5 - #8) HIGH & LOW LEVEL FLOAT TO SCADA VIA FCP2 HIGH & LOW LEVEL FLOAT TO SCADA VIA FCP2 HIGH & LOW LEVEL FLOAT TO SCADA VIA FCP2 HIGH & LOW LEVEL FLOAT TO SCADA VIA FCP2 HIGH & LOW LEVEL FLOAT TO SCADA VIA FCP1 HIGH & LOW LEVEL FLOAT TO SCADA VIA FCP1 HIGH & LOW LEVEL FLOAT TO SCADA VIA FCP1 HIGH & LOW LEVEL FLOAT TO SCADA VIA FCP1 EXISTING FILTER #1 EFFLUENT VALVE EXISTING FILTER #3 EFFLUENT VALVE EXISTING FILTER #4 EFFLUENT VALVE EXISTING FILTER #2 EFFLUENT VALVE PROPOSED FILTER #5 BACKWASH EFFLUENT VALVE PROPOSED FILTER #7 BACKWASH EFFLUENT VALVE PROPOSED FILTER #6 BACKWASH EFFLUENT VALVE PROPOSED FILTER #8 BACKWASH EFFLUENT VALVE E.05 39473 HXB-26,28,30 LXD-25 LXD-27 (4) NEW TURBIDIMETERS #5 - #8 RECEPTACLES, MATCH EXISTING LAYOUT FOR PROPOSED FILTERS #5 - #8. HOMERUN VARIOUS I/O CONTROL PER SCADA I/O LIST TO ALSO MATCH EXISTING LXD-28 120V-1Ø POWER (LXB-38) VARIOUS CONTROL I/O PER SCADA I/O LIST 1HP, 480V-3Ø, 2.1 FLA 1HP, 480V-3Ø, 2.1 FLA 1HP, 480V-3Ø, 2.1 FLA 1HP, 480V-3Ø, 2.1 FLA VARIOUS CONTROL WIRING IN CONDUIT PER SCADA I/O LIST VARIOUS CONTROL WIRING IN CONDUIT PER SCADA I/O LIST VARIOUS CONTROL WIRING IN CONDUIT PER SCADA I/O LIST VARIOUS CONTROL WIRING IN CONDUIT PER SCADA I/O LIST EXISTING 120V-1Ø CKT. MODIFY EXISTING CONTROL PER SCADA I/O LIST MODIFY EXISTING CONTROL PER SCADA I/O LIST MODIFY EXISTING CONTROL PER SCADA I/O LIST MODIFY EXISTING CONTROL PER SCADA I/O LIST NOTE: ALL NEW CONDUIT MATERIALS IN FILTER ROOM SHALL TYPICALLY MATCH EXISTING, STAINLESS HARDWARE PROPOSED FILTER #5 AIRWASH SUPPLY VALVE (SEE SECTION) PROPOSED FILTER #6 AIRWASH SUPPLY VALVE (SEE SECTION) PROPOSED FILTER #7 AIRWASH SUPPLY VALVE (SEE SECTION) PROPOSED FILTER #8 AIRWASH SUPPLY VALVE (SEE SECTION) FILTER TO WASTE VALVES NOT SHOWN IN THIS VIEW FOR CLARITY FIELD LOCATE EXISTING SUPPLEMENTAL BACKWASH SUPPLY VALVE, RUN CONTROL IN CONDUIT TO FCP1 PER I/O LIST. FIELD LOCATE PROPOSED SUPPLEMENTAL BACKWASH SUPPLY VALVE, RUN CONTROL IN CONDUIT TO FCP2 PER I/O LIST. FILTER CONTROL PANEL INTERCONNECTIONS DIAGRAM (TYPICAL OF EACH FILTER CLUSTER) NOT TO SCALE FILTER ELECTRICAL SECTION NOT TO SCALE AIRWASH SUPPLY VALVES (TYPICAL OF 4 EACH SIDE); DAISY CHAIN 120V-1Ø POWER TO EACH FROM FCP#. PROVIDE CONTROL WIRING IN CONDUIT PER I/O LISTS. HIGH LEVEL FLOATS (TYP.) TO FCP# FILTER TO WASTE SUPPLY VALVES (TYPICAL OF 4 EACH SIDE); DAISY CHAIN 120V-1Ø POWER TO EACH FROM FCP#. PROVIDE CONTROL WIRING IN CONDUIT PER I/O LISTS. FLOAT FOR MODULATING VALVE FOR SUPPLEMENTAL BACKWASH SUPPLY (ONE NEW, ONE EXISTING) FOUR (4) NEW TURBIDIMETERS TO MATCH EXISTING; POWER & CONTROL AS REQUIRED CLEARWELL CHEMICAL FEED ZONE DRY WELL 120V OUTLET IN PIT FOR TURBIDIMETER SAMPLE PUMP (TYP. 4) 16" FILTER ISOLATION VALVES (TYPICAL OF 4 EACH SIDE); DAISY CHAIN 120V-1Ø POWER TO EACH FROM FCP#. PROVIDE CONTROL WIRING IN CONDUIT PER I/O LISTS. FILTER #3 LEVEL TO FCP1 FILTER #4 LEVEL TO FCP1 FILTER #1 LEVEL TO FCP1 FILTER #2 LEVEL TO FCP1 FILTER #7 LEVEL TO FCP2 FILTER #8 LEVEL TO FCP2 FILTER #5 LEVEL TO FCP2 FILTER #6 LEVEL TO FCP2 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2