GFI WP GFI LXC-7,9 LXC-12 LXC-12 LXC-10 LXC-5 E E E E E E E E E E E E E E E E E E E E E E E E E E FO E E E E E E E E E E TO SCADA FIBER TO WTP MDPB-7 MDPB-6 MDPB-2 MDPB-3 MDPB-5 MDPB-4 1 7 2 8 PANEL LXC CIRCUIT NO. ITEM FEED WIRE SIZE AMPS CU. BUS POLE POLE AMPS WIRE SIZE ITEM FEED CIRCUIT NO. AMPERES VOLTS WIRE MAIN CONNECTION PHASE KAIC MOUNTING S.E.L. LOCATION A B C 1 60 120/208 4 MCB 3 ... SURFACE ... H.S. PUMP STATION A B C MAGMETER 1 12 20 HANGING HEATER HEATERS SPARE RTU-5 20 12 3 40 8 CAMERA LTG POLE 1 12 20 5 3 9 11 4 6 10 12 1 20 12 1 20 12 1 12 20 1 12 20 1 12 20 1 12 20 LIGHTS EXHAUST FAN RECEPT. ON POST & OUTSIDE BLDG. A 13 14 RAW WATER PUMP STATION RECEPT. SPACE B 15 16 SPACE SPACE C 17 18 SPACE SPACE NOTE: CONTRACTOR SHALL RECONNECT EXISTING LOADS AFTER PANEL IS RELOCATED, NO SPLICES. REMOVE UNUSED OR ABANDONED CONDUITS AS NECESSARY. 1 20 12 NEW P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern 2019 BID SET Author: CMOODY, Plot Date: 10/4/2019 7:56 AM Path: Z:\CAD_INCOMPLETE\2018022-00_CITY OF HUNTINGBURG_WS_DISTRIBUTION SYSTEM IMPROVEMENTS AND PLANT UPGRADES\025_PRODUCTIONDWG_DIV 2\MEP PLANS.DWG WATER SYSTEM IMPROVEMENTS DIV. II - WATER TREATMENT PLANT IMPROVEMENTS FOR THE CITY OF HUNTINGBURG DUBOIS COUNTY, INDIANA STATE OF No. PE11100002 A L A N F . B U R C H P R O F E S S I O N A L E N G I N E E R R E G I S T E R E D I N D I A N A HIGH SERVICE PUMP #2 480V-3Ø 114 AMPS HIGH SERVICE PUMP #1 480V-3Ø 114 AMPS EXISTING 15KVA TRANSFORMER TO BE RELOCATED EXISTING PANEL "LXC" TO BE RELOCATED EXISTING RTU-5 TO BE REPLACED EXISTING CHLORINE ANALYZER TO BE RELOCATED EXISTING UNIT HEATER TO REMAIN EXISTING EXHAUST FAN TO REMAIN FD PROPOSED ACTIVE FILTER ON CONCRETE HOUSEKEEPING PAD PROPOSED RTU-5 EXISTING PANEL "LXC" EXISTING 15KVA TRANSFORMER HIGH SERVICE PUMP #2 480V-3Ø 114 AMPS HIGH SERVICE PUMP #1 480V-3Ø 114 AMPS FD EXISTING UNISTRUT STAND TO BE REMOVED EXISTING H.S. PUMP #2 DISCONNECT TO BE REMOVED EXISTING H.S. PUMP #1 DISCONNECT TO BE REMOVED HIGH SERVICE PUMP BLDG. - EXISTING ELECTRICAL FLOOR PLAN SCALE: 1 2 " = 1'-0" HIGH SERVICE PUMP BLDG. - PROPOSED ELECTRICAL FLOOR PLAN SCALE: 1 2 " = 1'-0" EXISTING LIGHTS TO REMAIN (TYP. OF 4) 100HP 100HP EXISTING HATCH TO REMAIN 100HP 100HP CONTRACTOR TO FILL IN WITH CONCRETE TO MATCH EXISTING SLAB PROPOSED RAW WATER PUMP #1 VFD AND LIN REACTOR PROPOSED RAW WATER PUMP #2 VFD AND LINE REACTOR PROPOSED HIGH SERVICE PUMP #1 VFD AND LINE REACTOR PROPOSED HIGH SERVICE PUMP #2 VFD AND LINE REACTOR PROPOSED 480V-3Ø MAIN POWER DISTRIBUTION PANEL (MDPB) TWO (2) 1" CONTROL CONDUITS AND WIRE TO RAW PUMP STATION PROPOSED FIBER TO WTP FOR SCADA, SEE NETWORK DIAGRAM ONE (1) 1" SPARE CONDUIT TO RAW PUMP STATION w/ PULL ROPE CAPPED AT EACH END FOR FUTURE USE. TO RAW PUMP TO RAW PUMP TO WTP SEE SITE PLAN FOR CONTINUATION SAW CUT FLOOR TO WETWELL THEN SURFACE MOUNT TO INSTALL CONDUIT HIGH SERVICE PUMP BLDG. - WEST WALL ELEVATION SCALE: 1 2 " = 1'-0" EXISTING CHLORINE ANALYZER PROPOSED RTU-5 EXISTING PANEL "LXC" (RELOCATED) EXISTING 15KVA TRANSFORMER (RELOCATED) PROPOSED RAW WATER PUMP #1 VFD PROPOSED RAW WATER PUMP #2 VFD PROPOSED HIGH SERVICE PUMP #1 VFD PROPOSED HIGH SERVICE PUMP #2 VFD PROPOSED 480V-3Ø MAIN POWER DISTRIBUTION PANEL (MDPB) RUN COMMAND, STATUS AND POSITION TO SCADA EXISTING CHLORINE ANALYZER PROPOSED ACTIVE FILTER ON CONCRETE HOUSEKEEPING PAD RUN COMMAND, STATUS AND POSITION TO SCADA PROPOSED HIGH SERVICE AND RAW WATER PUMP LINE REACTORS NOTE: CONTRACTOR TO SAW CUT FLOOR AND RELOCATE SAMPLE LINE AND DRAIN LINE TO CHLORINE ANALYZER E.06 39472 VERTICAL AND HORIZONTAL SUPPORTS SHALL BE ALUMINUM UNISTRUT AS REQUIRED, SIZED BY CONTRACTOR TO ADEQUATELY SUPPORT EQUIPMENT EXISTING FLOOR DRAIN TO REMAIN FD PROPOSED DRAIN LINE, MATCH EXISTING PROPOSED FLOOR DRAIN, MATCH EXISTING NOTE: CONTRACTOR SHALL PROVIDE AND INSTALL ALL PROPOSED POWER AND CONTROL DEVICES PER SCADA I/O LISTS; CONDUIT AND WIRE AS REQUIRED WITHOUT SPLICES NOTE: CONTRACTOR SHALL REROUTE ALL EXISTING POWER AND CONTROL PER SCADA I/O LIST, RECONNECT NEW CONDUIT AND WIRE AS REQUIRED WITHOUT SPLICES. EXISTING PUMPS TO REMAIN (TYP. OF 2) PROPOSED CONCRETE HOUSEKEEPING PAD NOTE: SEPARATE ALL POWER AND CONTROL; SEPARATE ALL DIGITAL, ANALOG, ETHERNET AND FIBER. Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2